P121200 & P171600 Operating - Williams GRAVITY 1403622 Owner's Manual

Direct vent wall furnace
Hide thumbs Also See for GRAVITY 1403622:
Table of Contents

Advertisement

FOR YOUR SAFETY,
READ BEFORE
LIGHTING
WILLIAMS
GAS CONTROL
VALVE P121200 & P171600
I WARNING:
If you do not follow these
instructions
exactly, a fire or explosion
may result causing
property
damage,
personal
injury or loss of life.
C.
A,
This appliance
has a pilot which must be lighted
by
hand, When
lighting
the pilot, follow these
instructions
exactly.
O.
B.
BEFORE
LIGHTING
smell around the appliance
area
for gas. Be sure to smell next to the floor because
some
gas is heavier
than air and will settle
on the floor.
WHAT
TO DO IF YOU SMELL
GAS
• Do not try to light any appliance.
• Do not touch
any electric
switch; do not use any
phone
in your building,
• Immediately
call your gas supplier
from a neighbor's
phone.
Follow the gas supplier's
instructions.
• If you cannot
reach your gas supplier,
call the fire
department.
Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or
turn by hand, don't try to repair it, call a qualified
serv-
ice technician.
Force or attempted
repair may result in a
fire or explosion.
Do not usa this appliance
if any part has been under
water. Immediately
call a qualified
service
technician
to
inspect
the appliance
and to replace
any part of the
control
system
and any gas control which
has been
under water.
OPERATING
INSTRUCTIONS
1.
STOPI Read the safety information
above.
2.
Turn off all electric
power to the appliance
(if applicable).
3.
Set the thermostat
to lowest setting.
4.
Open control
access
panel,
5.
Push in gas control
knob slightly
and turn
clockwise
_
to "OFF."
@
_<-_-_
_) F
GAS CONTROL
KNOB
SHOWN
IN "OFF" POSITION
; []i_,l[]0[]a
i
I@
@
NOTE:
Knob
cannot
be turned
from
"PILOT"
to
"OFF"
unless
knob
is
pushed in slightly.
Do
not
force.
6.
Wait five (5) minutes
to clear out any gas, then smell for
gas, including
near the floor.
If you then smell gas, STOP!
Follow
"B"
in the safety
information
above. If you don't
smell gas, go to the next step.
7.
Loosen
wingnut
and open the pilot observation
door
(if
equipped).
8.
Find pilot--follow
metal tube from gas control.
The pilot is
mounted
on side of burner.
GENERATOR
{I
9.
Push in gas control
__..._ _ _
knob slightly
and turn
counterclockwise
_
to "PILOT."
PILOT
10.
Push in control
knob all the way and
BURNER
hold in. Immediately
light the pilot.
Continue
to hold the control
knob in for about
one (1)
minute after the pilot is lit. Release
knob and It will
pop back up. Pilot should
remain
lit. If It goes out,
repeat
steps 5 through
10,
• If knob does
not pop up when
released,
stop and
immediately
call your service
technician
or gas
supplier.
If the
pilot
will not stay lit after several
tries,
turn
the gas control
knob to "OFF"
and call your service
technician
or gas supplier.
11.
Close pilot observation
door, tighten
wingnut
(if equipped).
12.
Turn gas control
knob counterclockwise
_
to "ON",
13.
Close control
access
panel.
14.
Turn on all electric
power
to the appliance
(if applicable).
15.
Set thermostat
to desired
setting.
TO TURN OFF GAS TO APPLIANCE
1. Set the thermostat
to lowest setting.
2. Turn off all electric power to the appliance if service is to be performed (if applicable).
3. Open control access panel.
4. From "ON"
position, depress and turn gas control knob clockwise _
to "OFF"
position. Do not force.
5. Close control access panel.
WARNING:
DUE TO HIGH SURFACE TEMPERATURES
-- KEEP CHILDREN, CLOTHING,
FURNITURE OR ANY COMBUSTIBLE
MATERIAL AWAY FROM FURNACE.
IMPORTANT:
KEEP BURNER AND CONTROL COMPARTMENT
CLEAN.
CONNECTION
WIRING
DIAGRAM
FOR WALL
THERMOSTAT
MODELS
THERMOSTAT
r-7
GENERATOR
LAc
,-,I
/
I
LEGEND
--
FACTORY
WIRED
LOW VOLTAGE
SCREW
"FERMINAL LOW VOLTAGE
NOTE: if any of the odglnal wire as supplied
with the appliance has to be replased, use only
18 Ga., 4/64 insulaton, 105o C. AWM copper
wire or its equivalent.
--18--

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents