Digital Pocket thermometer With
StainleSS Steel Probe
NOTE Please keep this manual handy as you use your new product. It contains practical step-by-step instructions, as well as technical specifications and warnings you should know about. Do not use a dishwasher to clean the
probe or immerse in water or liquid. Clean the probe with water and a mild detergent. Wipe the cabinet with a damp cloth.
FEATURES
Easy operation:
Displays the temperature reading automatically.
Error-free Reading:
Digital display system ensures clear, error-free
reading at a glance.
Wide Range:
Measuring range from -50°C to 260°C
(-58°F to 500°F)
User Friendly:
User selectable normal or fast sampling cycle.
Plastic sleeve for sensor probe protection.
TEMPERATURE DISPLAY
AUTO - OFF
STAINLESS STEEL PROBE
MAX/MIN
ON/FAST
BATTERY COVER
METAL CLIP
PLASTIC SLEEVE
INSTALLING AND REPLACING BATTERIES
The unit uses 1 LR-44 size battery which is included in the package.
Follow these steps to install or replace battery:
1. Use a screw driver to open the battery cover. (Follow the direction of
the arrow.)
2. Insert a new battery (make sure positive (+) is facing you).
3. Replace the battery cover.
DISPLAY MODES
The thermometer has three different display modes:
DISPLAY MODE
FUNCTION
Normal
Shows the current measuring
temperature.
Maximum Temperature
Shows the maximum temperature
Memory
recorded since last memory reset.
Minimum Temperature
Shows the minimum temperature
Memory
recorded since last memory reset.
Auto Power OFF
The thermometer will
automatically turn off, if you do not
press any key for 6 to 7 minutes.
TEMPERATURE MEASUREMENT
1. Pull out the Pocket Thermometer from the plastic sleeve.
2. Pierce the sensor probe into meat or place the sensor probe into water.
Press and hold the [ON/FAST] button for a faster sensing rate, the
measuring temperature will show on the display in a second. The
temperature sensing rate will operate at its normal speed if you do not
press the [ON/FAST] button.
Caution: The effective measuring area is 1.5"–2" from the tip.
Do not expose the main unit out of the operating temperature.
Caution: Do not leave the thermometer in the food on the grill.
USING THE MAXIMUM AND MINIMUM
The Pocket Thermometer will automatically record the maximum and minimum
1.5"–2"
measurements.
You can recall those readings by doing the following:
EFFECTIVE
MEASURING AREA
FUNCTION
CURRENT
DISPLAY
Recall the
  22.3
Maximum
temperature
Recall the
s 28.8
Minimum
temperature
Return to current
t 18.8
temperature
RESETTING THE MAXIMUM OR MINIMUM
TEMPERATURE MEMORIES
The Pocket Thermometer will automatically record the maximum and minimum
measurements.
You can reset those readings by doing the following:
FUNCTION
CURRENT
DISPLAY
Reset the
s 28.8
Maximum
(With the
temperature
Maximum
memory
temperature
display)
Reset the
t 18.8
Minimum
(With the
DISPLAY
temperature
Minimum
memory
temperature
22.3
display)
Return to current
t 22.3
s 28.8
temperature
t 18.8
NOTE: You may like to clear the memory occasionally, so you can record
the Maximum / Minimum for a specified period.
AUTO 22.3
Resetting a memory will result in the current temperature being
displayed in the Maximum or Minimum memory display.
TEMPERATURE MEMORY
ACTION
NEXT
DISPLAY
Press [MAX/MIN] once
s 28.8
Press [MAX/MIN] once
t 18.8
again
Press [MAX/MIN] once
22.3
again
ACTION
NEXT
DISPLAY
Press and hold
s 22.3
[ON/FAST] button for 1
(The current
second.
temperature
will become
the maximum
memory)
Press and hold
t 22.3
[ON/FAST] button for 1
(The current
second.
temperature
will become
the minimum
memory)
Press [MAX/MIN] once
22.3
USING THE AUTO POWER OFF AND POWER OFF FUNCTIONS
Press the [AUTO-OFF] button. This enables "AUTO" to display, indicating
the thermometer will turn off automatically. If you do not press any key for
6 to 7 minutes, the thermometer will turn off automatically.
If you press the [AUTO-OFF] button once again, the thermometer will turn
off immediately.
SPECIFICATIONS
Operation temperature
: 0°C - 50°C (32°F - 122°F)
Temperature measuring range (probe) : -50°C to 260°C
(-58°F - 500°F)
Temperature display resolution
: Min 0. 1 °C to Max 0.5°C
(Min 0.2°F to Max 1°F)
Temperature sampling cycle
(Normal) : 10 seconds
(Fast) : 2 seconds
Power Source
: One (1) LR-44 battery
Battery life
: Approximate 6 Months
Metal probe size
: Diameter 2.8 mm ∞ 110 mm
Weight
: 30g (with plastic sleeve)
WARRANTY
Weber-Stephen Products Co., (Weber
) hereby warrants to the ORIGINAL
®
PURCHASER of this Digital Pocket Thermometer, that it will be free
from defects in material and workmanship from the date of purchase as
follows: 2 year(s) when assembled, and operated in accordance with the
printed instructions accompanying it.
Weber may require reasonable proof of your date of purchase.
THEREFORE, YOU SHOULD RETAIN YOUR SALES RECEIPT
OR INVOICE.
This Limited Warranty shall be limited to the repair or replacement of
parts that prove defective under normal use and service and which on
examination shall indicate, to Weber' s satisfaction, that they are defective.
If Weber confirms the defect and approves the claim, Weber will elect to
repair or replace such parts without charge. If you are required to return
defective parts, transportation charges must be prepaid. Weber will return
parts to the purchaser, freight or postage prepaid.
This Limited Warranty does not cover any failures or operating difficulties
due to accident, abuse, misuse, alteration, misapplication, vandalism,
improper installation or improper maintenance or service, or failure to
perform normal and routine maintenance. Deterioration or damage due
to severe weather conditions such as hail, hurricanes, earthquakes or
tornadoes, discolouration due to exposure to chemicals either directly or
in the atmosphere, is not covered by this Limited Warranty. Weber shall not
be liable under this or any implied warranty for incidental or consequential
damages. This warranty gives you specific legal rights, and you may also
have other rights, which vary from state to state.
Weber Customer Service (US only) 1-800-446-1071.
178722 8/07

Advertisement

loading

Summary of Contents for Weber 178722

  • Page 1 Weber’ s satisfaction, that they are defective. temperature will become If Weber confirms the defect and approves the claim, Weber will elect to the maximum repair or replace such parts without charge. If you are required to return memory) defective parts, transportation charges must be prepaid.
  • Page 2 Weber no se hace responsable bajo esta u otra garantía implícita de ningún daño indirecto o consecuente. Esta garantía le otorga derechos legales específicos, y puede que otros...