Side Burner Troubleshooting - Weber GENESIS A103.A Owner's Manual

Weber gas grill user manual
Table of Contents

Advertisement

Side Burner Troubleshooting

WARNING: Before attempting any troubleshooting steps, all gas controls and supply
valves should be in the OFF position.
Problem
Side Burner does not light.
Flame is low in HIGH position.
Flame is very yellow in
conjunction with the smell of gas,
OR
Burner makes popping noise in
conjunction with the smell of gas.
Push button ignition does not
work.
Side Burner maintenance
WARNING: All gas controls and supply valves
should be in the OFF position.
Check igniter:
Make sure wire is connected between igniter and
electrode. Check that igniter lock nut is tight.
Note: If the igniter works loose, carefully tighten the
igniter lock nut with an adjustable wrench or pliers.
Adjust igniter electrode to burner. Gap should be 1/8 to
3/16 inch from tip of electrode to burner. Spark should
be a white/blue color, not yellow.
1) Igniter
2) Igniter Wire
3) Venturi/Burner
(1)
(3)
Check
Is gas supply off?
Is the fuel hose bent or kinked?
Inspect the Weber Spider Stopper
Guard for possible obstructions.
(lockage of holes.)
Does burner light with a match?
4) 1/8 to 3/16 inch gap between electrode and burner
(2)
D-10
Cure
Turn supply on.
Straighten hose.
Clean Weber Spider Stopper Guard.
(See section "Annual Maintenance")
If match lights burner, checkigniter
(see below).
(4)