TECHNICAL
TECHNICAL
T
T
E
L
E
E
L
E
Allow Multiple Attendants to Answer Sequenced
F
e
a
t
u
r
e
s
F
e
a
t
u
r
e
s
• Compatible with ground or loop start lines
• Re-rings calls held by Viking's TMS-6X or
TMS-12A Call Sequencers
• Selectable ring cadence
• 10 REN load total
P
h
o
n
e
.
.
.
7
1
5
.
3
8
6
P
h
o
n
e
.
.
.
7
1
5
.
3
8
6
i
n
f
o
@
v
i
k
i
n
g
e
l
e
c
t
i
n
f
o
@
v
i
k
i
n
g
e
l
e
c
h
t
t
p
:
/
/
w
w
w
.
v
i
k
i
n
g
h
t
t
p
:
/
/
w
w
w
.
v
i
k
i
n
g
S
S
C
O
M
O
L
U
T
I
O
N
S
C
O
M
O
L
U
T
I
O
N
S
Calls While Eliminating Call Crashing
.
8
8
6
1
.
8
8
6
1
r
o
n
i
c
s
.
c
o
m
t
r
o
n
i
c
s
.
c
o
m
e
l
e
c
t
r
o
n
i
c
s
.
c
o
m
e
l
e
c
t
r
o
n
i
c
s
.
c
o
m
P
r
a
c
P
r
a
c
2
1
C
2
1
C
F
O
R
T
H
E
S
T
F
O
R
T
H
E
S
T
The SQRG-12 Sequential Ring Generator is
designed for applications where more than
one person answers incoming calls and
those persons may be in locations where the
TMS-6X or TMS-12A is not visible.
The SQRG-12 eliminates confusion about
which line to answer next by displaying the
oldest call as a ringing line on all phones in
the phone system.
A
p
p
l
i
A
p
p
l
• Generate automatic oldest call notification for
the TMS-6X
• Generate automatic oldest call notification for
the TMS-12A
• Eliminates call crashing on outbound calls
when used with Viking's TMS-6X or TMS-
12A Call Sequencers
S
p
e
c
S
p
e
c
Power: 120V AC/13.8V AC 1.25A UL listed adapter pro-
vided
Dimensions: 210mm x 160mm x 44mm (8.25" x 6.25" x
1.75")
Shipping Weight: 1.36 Kg (3 lbs)
Environmental: 0°C to 32°C (32°F to 90°F) with 5% to
95% non-condensing humidity
REN: 10.0
Connections: (2) RJ21X jacks, (1) RJ14 jack
Maximum Run: 305m (1000 ft) between SQRG-12 and
sequencer
SQRG-12
SQRG-12
Sequential Ring
t
i
c
e
t
i
c
e
Generator
E
N
T
U
R
Y
E
N
T
U
R
Y
c
a
t
i
o
n
s
i
c
a
t
i
o
n
s
i
f
i
c
a
t
i
o
n
s
i
f
i
c
a
t
i
o
n
s
July 28, 2006