Vermont Castings Defiant 1610CE Homeowner's Installation And Operating Manual

Vermont castings defiant non-catalytic woodburning stove
Hide thumbs Also See for Defiant 1610CE:

Advertisement

0968
Defiant cover
11/00
SAFETY NOTICE: IF THIS APPLIANCE IS NOT PROPERLY INSTALLED, OPERATED AND
MAINTAINED, A HOUSE FIRE MAY RESULT.
TO REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLATION INSTRUCTIONS. FAILURE TO
FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN
DEATH. CONTACT LOCAL BUILDING OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION
INSPECTION REQUIREMENTS IN YOUR AREA.
Do Not Discard This Manual: Retain for Future Use
Defiant
Non-Catalytic
Woodburning Stove
Model 1610CE
Homeowner's
Installation and

Operating Manual

For use in Europe
30003846 4/08 Rev. 1

Advertisement

Table of Contents
loading

Summary of Contents for Vermont Castings Defiant 1610CE

  • Page 1: Operating Manual

    DEATH. CONTACT LOCAL BUILDING OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA. Do Not Discard This Manual: Retain for Future Use Defiant Non-Catalytic Woodburning Stove Model 1610CE Homeowner’s Installation and Operating Manual For use in Europe 30003846 4/08 Rev. 1...
  • Page 2 14.5 kW (49,500 BTU/hr). The Defiant Model #1610CE has been tested to current standards. The test standards are UL-1482 and UL-737 for the United States, and EN13240:2001 + A2:2004 for Europe. The Defiant is listed for burning wood only. Do not burn other fuels.
  • Page 3: Table Of Contents

    With its 1998 return, a new Defiant incorporated all the finest aesthetic, convenience, and performance features to be found on any wood stove. After continued development, this Defiant model 1610CE non-catalytic model continues the tradition of the original Defiant while incorporating the very latest combustion technology. In a sense, the new Defiant has been 23 years in the making.
  • Page 4: Specifications

    Defiant 1610CE Non-Catalytic Woodburning Stove Defiant, Model 1610CE Nominal heat output ...14.5 kW (49,500 BTU/hr) Mnimum flue draught ...12 Pa (0.048” WG) Mean flue gas temp ... 419° C (786° F) Efficiency (space heating) ...72.3% Area heated ...223 sq m (2,400 sq. ft.) Fuel size/type ...610 mm (24”) wood...
  • Page 5: Installation

    All local regulations, including those referring to national and European standards need to be complied with when installing this stove. 30003846 Defiant 1610CE Non-Catalytic Woodburning Stove Installation In some modern, super-insulated homes, there may be inadequate air supply for combustion because of insuf- ficient air infiltration into the building.
  • Page 6 Defiant 1610CE Non-Catalytic Woodburning Stove What Kind of Chimney to Use You must connect the Defiant to a code-approved masonry chimney with a flue liner, to a relined masonry chimney that meets local codes, or to a prefabricated metal chimney. Figure 3 illustrates the two types. The chimney and chimney connector must be in good condi- tion and kept clean.
  • Page 7 Fig. 4 Chimney connector. Chimney connector 30003846 Defiant 1610CE Non-Catalytic Woodburning Stove flue collar with three #10 x 1/2” sheet metal screws. Lift off the griddle, and shield the stove’s surface between the griddle opening and the front of the flue collar to protect the finish when you drill the front...
  • Page 8 Defiant 1610CE Non-Catalytic Woodburning Stove Chimney Elbow Slip Pipe Standard Connector Oval to Round Adapter Flue Collar Fig. 5 An exploded view of the chimney connection in a free- standing masonry installation. ST492 Defiant securely in place. Most chimney breeches incorporate freestanding thimbles, but the fit must be snug and the joint between...
  • Page 9 25 mm (1”) clear of the wall. 30003846 Defiant 1610CE Non-Catalytic Woodburning Stove Your local dealer or your local building inspector can provide details for other approved methods of passing a chimney connector through a combustible wall in your area.
  • Page 10 Defiant 1610CE Non-Catalytic Woodburning Stove Appliance Doors At least 150 mm Perimeter should be clearly marked e.g. edge of superimposed hearth a) Fireplace recess Fig. 10 Noncombustible hearth surface dimensions. Floor Protection for Fireplace Installation Do not assume that your fireplace hearth is completely noncombustible.
  • Page 11: Clearance Diagrams

    1.5 Elevation Without Shield Fig. 12 Connecting fluepipe clearances. 30003846 Defiant 1610CE Non-Catalytic Woodburning Stove Fig. 11 Minimum clearances. Connecting Flue Pipe - Clearances ST486a Single wall connecting fluepipes can reach extremely Defiant EU high temperatures; therefore, clearances from the con- necting fluepipe (chimney connector) must comply with...
  • Page 12: Assembly

    Defiant 1610CE Non-Catalytic Woodburning Stove Set Up Your Stove Cast iron stoves are heavy, and it will take two to four people to move your Defiant into position. Wipe the protective coating of oil from the griddle with a clean dry rag or a paper towel.
  • Page 13 86 mm (3³⁄₈") screw through the ceramic shaft and into the bright metal nub. (Fig. 23) Tighten carefully until snug. 30003846 Defiant 1610CE Non-Catalytic Woodburning Stove Fig. 22 Attach the thermostat handle. Fig. 23 Assemble the front door handle. Fan Kit Installation 1.
  • Page 14: Operation

    Defiant 1610CE Non-Catalytic Woodburning Stove The Defiant Controls Two controls regulate the performance of the Defiant: a primary air control supplies oxygen for the fire, and a damper directs air flow within the stove to activate and deactivate the catalytic combustor. (Fig. 25) Symbols cast into the stove are reminders of the correct directions for using the controls.
  • Page 15 ‘airwash,’ makes clear fire viewing possible at most fir- 11/00 ing levels. 30003846 Defiant 1610CE Non-Catalytic Woodburning Stove Andirons Help Protect the Glass Your stove has andirons to keep logs away from the glass panels. The andirons are essential to maintain clear fire viewing, and should be left permanently in...
  • Page 16 Defiant 1610CE Non-Catalytic Woodburning Stove agement information on Page 26 to see how the size, type, and location of your chimney will affect your stove operation. When thermometer readings drop below 175° C (350° F) it is time to adjust the air control for a higher burn rate or to reload the stove.
  • Page 17 5. Close the damper when the griddle temperature reaches 230° C (450° F). 30003846 Defiant 1610CE Non-Catalytic Woodburning Stove Fig. 32 Add larger pieces of wood as the fire begins to burn well. 6. Adjust the air control for your desired heat output.
  • Page 18 Defiant 1610CE Non-Catalytic Woodburning Stove operating temperature quickly. Use this sequence as a guide to successful refueling: NOTE: Door handles can be hot. A glove has been included with your stove. We recommend using this glove whenever operating door or damper controls and especially when operating the top griddle.
  • Page 19: Draft Management

    This uses the house as insulation for the flue and allows some heat release 30003846 Defiant 1610CE Non-Catalytic Woodburning Stove Draft Management into the home. An indoor chimney won’t lose its heat to the outdoors, so it takes less heat from the stove to heat it up and keep it warm.
  • Page 20 Defiant 1610CE Non-Catalytic Woodburning Stove they must turn, it leaves some pipe in the room for heat transfer, and it gives you long-term flexibility for install- ing a different stove without relocating the thimble. There should be no more than eight feet of single-wall stove pipe between the stove and a chimney;...
  • Page 21: Maintenance

    If you need to replace the glass, use only the high temperature ceramic glass supplied by Vermont Cast- 30003846 Defiant 1610CE Non-Catalytic Woodburning Stove Maintenance ings. Do not use substitutes. Be sure to specify left or right glass; the panels are not interchangeable, due to a heat-reflective coating on the side toward the room.
  • Page 22 Defiant 1610CE Non-Catalytic Woodburning Stove Adjust the Damper as Needed The tension on the Defiant’s damper is adjustable to compensate for compression of the gasket that seals the damper to the upper fireback. To adjust the damper: 1. Remove the griddle. Loosen the lock nut at the cen- ter of the damper.
  • Page 23 The directions for adjusting the latches are on Page 30. 30003846 Defiant 1610CE Non-Catalytic Woodburning Stove All Gasketed Construction Gaskets Other gaskets form seals between all other non-moving parts, but these are not subject to the same wear and deterioration as gaskets on moving parts.
  • Page 24 Defiant 1610CE Non-Catalytic Woodburning Stove Clean the chimney connector by disconnecting the sec- tions, taking them outside, and removing any deposits with a stiff wire brush. Reinstall the connector sections after cleaning, being sure to secure the joints between individual sections with sheet metal screws.
  • Page 25: Replacement Parts

    CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. Defiant Woodburning Stove Model 1610CE 30003846 Defiant 1610CE Non-Catalytic Woodburning Stove 2850 Defiant N parts 11/05 46 45...
  • Page 26 Defiant 1610CE Non-Catalytic Woodburning Stove Defiant Woodburning Stove Item Description 1. Side Insulation 2. Right Side Brick 3. Left Side Refractory 4. Brick Support Bracket 5. Griddle Gasket 6. Back 7. Left Heat Deflector 8. Right Heat Deflector 9. Shoe Refractory 10.
  • Page 27 Defiant Woodburning Stove Shell Enamel Parts - Defiant Model 1610CE Part Name Classic Biscuit 30002834 30002874 Left Side 30002832 30002872 Right Side 30002831 30002871 Flue Collar 30001576 30002947 Front 30002830 30002873 Ashlip 30002811 30002870 Left Door 30002854 30002879 Sub Assy...
  • Page 28: Warranty

    For Vermont Castings Defiant, Non-Catalytic Wood Stove Limited Lifetime Warranty CFM Corporation warrants that all refractory brick and material used in this product will be warranted against deterioration not resulting from physical damage or overloading of the woodstove for the lifetime of this product.

Table of Contents