Majestic NVC36 Installation And Homeowners Operating Instructions

Majestic NVC36 Installation And Homeowners Operating Instructions

Decorative gas appliance

Advertisement

INSTALLER/CONSUMER
SAFETY INFORMATION
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND USING
APPLIANCE
IMPORTANT: Read all instructions
and warnings carefully before starting
installation. Failure to follow these
instructions may result in a possible
fire hazard and will void the warranty.
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury or loss of life.
FOR YOUR SAFETY
Installation and service must be
performed by a qualified installer,
service agency, or the gas supplier. Do
not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
FOR YOUR SAFETY
If you smell gas:
Do not touch electrical switches.
Do not try to light any appliance.
Do not use the phone in your building.
Immediately call your gas supplier from
a neighbor's phone.
Follow your gas supplier's instructions.
If you cannot reach your gas supplier,
call the fire department.
Decorative Gas Appliance
Models: NVC36, NVC39, NVC43
Installation and Homeowners
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Operating Instructions
GF461
NVC cover
3/3/97
C E RT I F I E D
20000194 9/06 Rev. 6

Advertisement

Table of Contents
loading

Summary of Contents for Majestic NVC36

  • Page 1 Follow your gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department. Decorative Gas Appliance Models: NVC36, NVC39, NVC43 Installation and Homeowners Operating Instructions INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
  • Page 2: Table Of Contents

    NVC Series B-Vent Thank you and Congratulations on your purchase of a PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING THE APPLIANCE IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Installation Instructions ...
  • Page 3: Installation Instructions

    Installation & Operating Instructions This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSA-B149.1 Natural Gas and Propane In- stallation Code. If the unit is being installed in a mobile home, the installation should comply with the current CAN/CSA Z 240.4 code.
  • Page 4: Fireplace Dimensions

    Outside Air Access (See inset A) Rough Opening Depth Fig. 1 Fireplace specifications and framing dimensions. Ref. Fireplace Dimensions Rough Opening Width Appliance Dimensions NVC36 NVC39 Framing Dimensions ������� 36¹⁄₂" (927 mm) 39¹⁄₂" (1003 mm) �������� 34³⁄₄" (883 mm) 35"...
  • Page 5: Clearance To Combustibles

    Clearance to Combustibles Appliances Top ... 0” (0 mm) Bottom ... 0” (0 mm) Side ... 0” (0 mm) Back ... 0” (0 mm) Perpendicular Sidewall ... 0” (0 mm) Top of unit to ceiling ... 36” (914 mm) Front of unit to combustibles ... 36” (914 mm) Venting B-Vent ...
  • Page 6: Framing And Finishing

    33,000 Natural Electronic Ignition 33,000 33,000 Natural 5.5" w.c. 11.0" w.c. 14.0" w.c. 14." w.c. 3.5" w.c. 10.0" w.c. NVC36 / NVC39 / NVC43 CERTIFIED To Vented Gas Fireplace Heaters High Elevations 20000194 Min. Input 17,500 18,750 17,500 18,750 17,500...
  • Page 7: Gas Line Installation

    Gas Line Installation When purging gas line the fornt glass must be removed. Purging gas lines must com- ply with ANSI Z223.1/NFPA 54 in USA and CSA B149.1 in Canada. The gas pipeline can be brought in through the right or left side of the appliance, as well as the bottom.
  • Page 8: Eb-1 Electrical Box

    NVC Series B-Vent EB-1 Electrical Box The fireplace, when installed, must be electrically connected and grounded in accordance with local codes or, in the ab- sence of local codes, with the current CSA C22.1 Canadian Electrical Code For USA installations follow the local codes and the national electrical code ANSI/NFPA No.
  • Page 9: Venting Runs

    Attic Installation Firestop position when area above ceiling is an attic. Ceiling Installation Firestop position when area above ceiling is NOT an attic. Fig. 9 Firestop/draftstop positions. FP384 FIRESTOP 11/21/96 adapted from IGF53 20000194 Nails (4) Firestop Spacer Joist (Firestop/draftstop appearances may vary.
  • Page 10: Operating Instructions

    NVC Series B-Vent Glass Information Only glass approved by CFM Corporation should be used on this fireplace. • The use of any non-approved replacement glass will void all product warranties. • Care must be taken to avoid breakage of the glass. •...
  • Page 11: Lava Rock, Ember Material Placement

    Top Right Log BB10 BB9 Log Top Left BE5 Log Rear Log Front Left NVC36 BC8 Log Top Left Rear BC5 Log NVC36 LOG SET Front 8-11-98 Left NVC39 BD8 Log Rear NVC39 LOG SET 8-12-98 BD9 Log Top Left Log Front...
  • Page 12: Inspecting The Venting System

    NVC Series B-Vent NVC36 NVC39 NVC43 Fig. 16 Approximate flame heights for each model. FP393 8/25/98 Inspecting the Venting System NVC FLAME HEIGHTS This appliance venting system is designed and con- structed to develop a positive flow adequate to remove flue gases to the outside atmosphere.
  • Page 13: Lighting And Operating Instructions

    Lighting and Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This heater has a pilot which must be lit manu- ally.
  • Page 14: Vent Safety Switch

    NVC Series B-Vent Vent Safety Switch This fireplace incorporates the use of a Vent Safety Shut-off Switch. The sensor and wiring are factory installed and should not be removed or altered during installation. In the event of total flue blockage the system will detect the increased heat buildup and will automatically shut down the main burner assembly.
  • Page 15: Troubleshooting

    Honeywell Electronic Ignition START Turn gas supply off Turn ON/OFF Switch to call for heat. Power to module (24V nominal) Spark across Ignitor Sensor gap Turn gas on Pilot burner lights? Spark stops when pilot is lit? Main Burner lights? System runs until ON/OFF switch is in "OFF"...
  • Page 16 NVC Series B-Vent Remove glass door before service work START Gas Supply On Pilot Lights With Piezo Ignitor Pilot Stays Lit Pilot Lights Main Burner System Ok Troubleshooting Honeywell VS8421 CHECK • • • • • • • • • •...
  • Page 17 Nova SIT 820 Standing Pilot START Gas Supply On Pilot Lights With Piezo Ignitor Pilot Stays Lit Pilot Lights Main Burner System Ok. 20000194 Troubleshooting CHECK Supply Line Hooked Up Shutoff Valve Open Lockout Has Engaged. Wait 60 Seconds and Try Again. Piezo Nut Tight for Good Ground.
  • Page 18: Maintenance

    NVC Series B-Vent Burner and Burner Compartment It is important to keep the burner and the burner compartment clean. At least once per year the logs and lava rock/ember material should be removed and the burner compartment vacuumed and wiped out. Remove and replace the logs as per the instructions in this manual.
  • Page 19: Replacement Parts

    NVC36 4a/b CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. NVC36/39/43 Ref. Description Log Set Complete Log Front Left Log Front Right Log Rear Log Top Left...
  • Page 20: Parts List

    NVC Series B-Vent NVC36/39/43 (continued) Ref. Description Orifice Front Burner-Nat. Orifice Front Burner-LP Pilot Assy- SIT Top Convertible, LP Pilot Assy - SIT Top Convertible, Nat. Orifice Pilot - Nat. Orifice Pilot - LP Pilot Tubing w/Fittings Electrode Ignitor 11a.
  • Page 21: Optional Accessories

    Fan Kits FK12 Fan Assembly 1. Open louvre assembly bottom. 2. Install FK12 fan in back of unit between hearth sup- ports. 3. Secure fan on velcro strips. 4. Power to the fan can be supplied by plugging the supply lead into a conveniently located wall socket or by using a hard-wired EB-1 connector box.
  • Page 22: Wiring Instructions

    24 hour clock Wall mounted thermostat control Ceramic Refractory Panels Ceramic refractory panels are available to line the fire- box area. Unit Kit Model NVC36 NV36CR NVC39 NV39CR NVC43 NV43CR Take care when handling the refractory panels as they are fragile until held in place and supported.
  • Page 23: Ceramic Refractory Panels

    Fig. 28 Arched door front in place. Decorative Bay Windows FP1195 Arched door front When fitting the Bay Window Kits, the original 2/27/02 djt front frame/glass assembly MUST remain in place. The Bay Window kit is fitted over the existing front glass.
  • Page 24: Receptacle Box

    NVC Series B-Vent 20000194...
  • Page 25 NVC Series B-Vent 20000194...
  • Page 26 NVC Series B-Vent 20000194...
  • Page 27: Limited Lifetime Warranty

    PRODUCT COVERED BY THIS WARRANTY All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic or Northern Flame brand gas fireplaces equipped with an Insta-Flame Ceramic Burner, or standard steel tube burner. BASIC WARRANTY CFM Corporation (hereinafter referred to collectively as the Company) warrants that your new Vermont Castings or Majestic Gas Fireplace/ Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject to the following conditions...
  • Page 28 Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency (%) NVC36RN NVC36RP NVC36RFN NVC36RFP NVC36EN NVC36EP NVC39RN NVC39RP NVC39RFN NVC39RFP NVC39EN NVC39EP NVC43RN NVC43RP NVC43RFN NVC43RFP NVC43EN NVC43EP CFM Corporation 2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www.cfmcorp.com 29.4 29.4 29.4...