PROPANE/LP GAS RESIDENTIAL HEATERS

SPECIFICATIONS

Btu (Variable)
Type Gas
Ignition
Pressure Regulator Setting
Inlet Gas Pressure (in. of water) *
Maximum
Minimum
Dimensions, Inches (H x W x D)
Heater
Carton
Weight (pounds)
Heater
Shipping
* For purposes of input adjustment
For more information, visit www.desatech.com
®
15,000/30,000
Propane/LP Only
Piezo
8" W.C.
14"
11"
23.75 x 25.9 x 8.5
25.8 x 28.7 x 10.1
29
35
TECHNICAL
SERVICE
You may have further questions about in-
stallation, operation, or troubleshooting. If
so, contact DESA International's Technical
Service Department at 1-800-323-5190.
You can also visit DESA International's
technical
www.desatech.com.

SERVICE HINTS

When Gas Pressure Is Too Low
• pilot will not stay lit
• burner(s) will have delayed ignition
• heater will not produce specified heat
• propane/LP gas supply may be low
When Gas Quality Is Bad
• pilot will not stay lit
• burner(s) will produce flames and soot
• heater will backfire when lit
You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local
propane/LP supplier.