Summary of Contents for United States Stove Ashley Heritage 5700
Page 1
UNITED STATES STOVE COMPANY Ashley Heritage OWNER’S MANUAL Please read this entire manual before installation and use of this appliance. Failure to follow these instructions could result in property damage, bodily injury, or even death. Contact your local building or fire officials about restrictions and installation inspection requirements in your area.
IMPORTANT: Read this entire manual before installing and operating this product. Failure to do so may result in property damage, bodily injury, or even death. Proper installation of this stove is crucial for safe and efficient op- eration. Install vent at clearances specified by the vent manufacturer.
Page 4
MUST BE MAINTAINED. This appliance is not intended for commercial use. Note: United States Stove Company grants no warranty, implied or stated, for the installation or maintenance of your stove, and assumes no responsibility of any consequential damage(s). SAFETY PRECAUTIONS...
Watts (operational) Watts (igniter running) FUEL CONSIDERATIONS Ashley Heritage Model 5700 Your tion of Pellet Fuel Industries standards. (Minimum of 40 lbs density per cubic ft, 1/4” to 5/16” diameter, length no greater than 1.5”, not less than 8,200 BTU/lb, moisture under 8% by weight, ash under 1% by weight, and salt un- der 300 parts per million).
An Alcove Unit—supported by (4) legs and placed on a non-combustible floor surface in compliance with clearance requirements for an alcove installation. Ashley Heritage Model 5700 Your (see SPECIAL MOBILE HOME REQUIREMENTS). It is recommended that only a authorized technician install your specialist.
CLEARANCES Your Ashley Heritage Model 5700 stove has been tested and listed for installation in residential, mobile home, and alcove applications in accordance with the clearances given in FIGURES 3-5 and TABLE 1. NOTE: Distance “C” on the right-hand side of your to be greater than the minimum required clearance for suitable access to the control panel.
VENTING REQUIREMENTS Install vent at clearances specified by the vent manufacturer. Do not connect the pellet vent to a vent serving any other appliance or stove. Do not install a flue damper in the exhaust venting system of this unit. The following installation guidelines must be followed to ensure conformity with both the safety listing of this stove and to local building codes.
VENT TERMINATION CLEARANCES: A) Minimum 4-foot clearance below or beside any door or window that opens. B) Minimum 1-foot clearance above any door or window that opens. C) Minimum 3-foot clearance form any adjacent building. D) Minimum 7-foot clearance from any grade when adjacent to public walkways. E) Minimum 2-foot clearance above any grass, plants, or other combustible materials.
INSTALLATION THROUGH THE WALL INSTALLATION (RECOMMENDED INSTALLATION) To vent the unit through the wall, connect the pipe adapter to the exhaust motor adapter. If the exhaust adapter is at least 18-inches above ground level, a straight section of pellet vent pipe can be used through the wall.
MUST be used when an outside air pipe is installed through the side of a building. The outside air termination MUST be at least 1-foot away from the exhaust system termination. Ashley Heritage Model 5700 The outside air pipe on your must be at least 1 7/8”...
SPECIAL MOBILE HOME REQUIREMENTS WARNING! - DO NOT INSTALL IN A SLEEPING ROOM CAUTION! - THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL, AND CEILING/ ROOF MUST BE MAINTAINED. In addition to the previously detailed installation requirements, mobile home installations must meet the following requirements: •...
A working smoke detector must be installed in the same room as this product. HOW YOUR STOVE WORKS Ashley Heritage Model 5700 Your ger fuel feed system that is operated by a microprocessor con- trolled digital circuit board.
Ashley Heritage Model lower right-hand side of your 5700 stove (see FIGURE 11). Pressing the “ON” button on the control panel will be- gin the start-up sequence for the stove. Fuel will begin...
4) Check that both augers and the exhaust blower are operating (the room air blower will not start at this time). DO NOT open the viewing door, the auto-start igniter will get very hot during this test. The stove will auto- matically shut down after approximately 23 minutes.
NOTE: The unit will also shut down in the event of an exhaust blower failure; if this is the case, the unit will not re- start and you must contact Customer Service at (800) 750-2723. SAFETY AND CONVENIENCE FEATURES Ashley Heritage Model 5700 Your in proper working order before feeding fuel to the burn pot. Because the stove works using an induced draft pres- sure, the stove will not continue to operate if the viewing door or ash pan slides are left open;...
Failure to clean and maintain this unit as indicated can result in poor performance and safety haz- ards. Unplug your stove’s electrical cord prior to removing the back panel or opening the exhaust sys- tem for any inspection, cleaning, or maintenance work. Never perform any inspections, cleaning, or maintenance on a hot stove.
MAINTENANCE Ashley Heritage ” tact your Authorized “ Dealer to obtain a can of suitable high-temperature paint. GLASS We recommend using a high quality glass cleaner. Should a build up of creosote or carbon accumulate, you may wish to use 000 steel wool and water to clean the glass. In the event you need to replace the glass, only high tem- Ashley Heritage ”...
Page 19
MAINTENANCE FIGURE 12 MAINTENANCE PARTS DIAGRAM -19-...
Disconnect the power cord before performing any maintenance! NOTE: Turning the ON/OFF Switch to ”OFF” does not disconnect all power to the electrical components of the stove. Never try to repair or replace any part of the stove unless instructions for doing so are given in this manual.
FACTORY DEFAULT SETTINGS Setting (P1) Auger Period (P2) Cold Stove Temp (P3) Hot Stove Temp (P4) Hot Stove Hysterisis (P5) Room Air On Temp (P6) Auger Load Time (P7) Igniter On Time (P8) Start-Up Time (P9) Factory Defaults (PA) Room Fan On Temp (PB) Auger Start Operation (PC) Auger Operation Select FACTORY DEFAULTS...