Page 1
72 SERIES Advanced Remote Starters & Vehicle Security Systems INSTALLATION MANUAL THIS MANUAL COVERS THE OPERATIONS OF THE 1172 AND 1272 SERIES REMOTE VEHICLE STARTERS WARNING: NEVER USE AN AUTOMATIC TRANSMISSION STARTER IN A MANUAL TRANSMISSION VEHICLE FCC ID NOTICE This device complies with Part 15 of the FCC rules.
72 SERIES INSTALL MANUAL WIRING DIAGRAM...Page 3-4 Connector Pin Configuration Antenna Connection Door Lock Connector Bypass Connector Data Port Connector Tach Learning...Page 5 Auto Tach/ Tachless Learning Hybrid Mode Low Idle Learn Wire Description...Page 6-7 6-Pin Ignition Connector 2-Pin Park Light & Ground Connector 3-Pin Lock &...
Page 3
PAGE 3 WIRE DIAGRAM SYSTEM PROGRAMMING - Menu 1 OUTPUT TO ACTIVATE THE STARTER CIRCUIT OUTPUT TO ACTIVATE 12VOLT/ 30 AMP MAIN POWER INPUT 12VOLT/ 30 AMP MAIN POWER INPUT SELECTABLE OUTPUT* (DEFAULT 2ND IGNITION) OUTPUT TO ACTIVATE THE PRIMARY SYSTEM GROUND INPUT/ CHASSIS GROUND SELECTABLE PARK LIGHT OUTPUT (DEFAULT POSITIVE) (-) REARM OUTPUT - PROGRAMMABLE...
72 SERIES INSTALL MANUAL OUTPUT TO ACTIVATE DOOR LOCK CIRCUIT (-) OUTPUT FOR VOLTAGE INVERTER* OUTPUT TO ACTIVATE DOOR UNLOCK CIRCUIT (-) GROUND WHEN RUNNING (BYPASS TURN ON) GROUND FOR BYPASS MODULE BYPASS MODULE DATA COMMUNICATION PORT** *The default setting is for idatalink modules. For Fortin bypass modules power- up the system with the Fortin module connected to the data port to set the default to Fortin bypass module.
PAGE 5 TACH LEARN SYSTEM PROGRAMMING - Menu 1 AUTO TACH/ TACHLESS LEARNING Start the vehicle with the ignition key. NOTES: When tach learning the system first sends out a request for tach from the data port. If it gets a valid rpm response over 750 rpm then it goes into data tach mode (3 flashes).
1 honk confirms program mode entered followed by 5 honks confirming transmitter program mode PROGRAMMING REMOTE’S Press & Release LOCK (START ON 1172) button on 1st Remote to be Programmed for Normal Operation If remote(s) are to be programmed for "PADLOCK" skip and goto step 6.
Page 9
6 - To exit Program Mode, turn the key off. (Confirmed by Long Horn Chirp) 1172 SERIES- To access Menu 1 press and release the program switch again after entering program mode. The LEDs will flash in a series of 1. (Menu 1 Setting 1) To access Menu 4 the system must be programmed for Setting 1 or 2 in program menu 3 setting 9.
72 SERIES INSTALL MANUAL DIAGNOSTICS CHART If the remote starter does not activate when the start button is pressed the park lights will flash a diagnostic to indicate what shutdown input has been triggered. For example: If the start button is pressed the park lights flash 3 times slowly.
Page 13
72 SERIES PAGE 13 INSTALLATION NOTES INSTALL MANUAL SYSTEM PROGRAMMING - Menu 1 2 BUTTON REMOTE WHEN PROGRAMMED FOR 2 BUTTON OR LOCK/UNLOCK TOGGLE PRESSING UNLOCK AND START AT THE SAME TIME WILL SELECT MENU 4 WHILE IN PROGRAM MODE. THE SYSTEM MUST BE PROGRAMMED FOR 2 BUTTON REMOTE LOCK/UNLOCK TOGGLE TO OPERATE THE LOCK FEATURE ON THE VEHICLE.
72 SERIES INSTALL MANUAL DOOR LOCK DIAGRAMS Door lock Output Door lock Output USE SPDT 12v Relay Door lock Output USE SPDT 12v Relay Door lock Output SYSTEM PROGRAMMING - Menu 1 RELAY DIAGRAMS Vehicle's Lock/Unlock Switch Green Blue Green Blue Green Blue...
Page 15
PAGE 15 RELAY DIAGRAMS SYSTEM PROGRAMMING - Menu 1 DOOR LOCK DIAGRAMS Door lock Output USE SPDT 12v Relay Door lock Output USE SPDT 12v Relay Door lock Output USE SPDT 12v Relay Green Blue Green Blue Green Blue 72 SERIES INSTALL MANUAL Ground Vehicle's Lock/...
Page 16
72 SERIES PAGE 16 INSTALL MANUAL **FOR DETAILED VEHICLE WIRING INFORMATION GO TO: http://www.ultrastarters.com/wiring_diagrams.html This site is for registered and authorized dealer only. If you are an authorized dealer but have been registered, please fill out the service request form at http://www.ultrastarters.com/wiring_diagrams.html PRODUCT INFORMATION: www.ultrastarters.com TECHNICAL SUPPORT: support@ultrastarters.com...