Download Print this page

Toshiba PORTEGE M400 Maintenance Manual page 71

Toshiba personal computer
Hide thumbs Also See for PORTEGE M400:

Advertisement

2.4 System board Troubleshooting
Table 2-3 Debug port (Boot mode) error status (3/10)
D port status
(F100h)
Initialization of H/W (before DRAM
recognition)
Initialization of PIT channel 1
F101h
Checking DRAM type and size
(at cold boot)
Testing the stack area of SM-RAM
F102h
Configuring cache memory
Permission of L1/L2 cache
memory
Checking the access of a CMOS
(Only in Cold Boot)
Examining the battery level of
CMOS
Checksum check of CMOS
Initializing data in CMOS (1)
Setting up of IRT status
Storing the size of DRAM
F103h
Branch of resuming (only in Cold
Boot)
PORTEGE M400 Maintenance Manual (960-541)
Inspection items
Details
Initialization of MCHM
Initialization of ICH7M.D30.Func0
Initialization of ICH6M.D31.Func0
Initialization of ICH6M.D31.Func1/2
Initialization of USB controller
Initialization of ICH7M.D31.Func3
Initialization of TI controller
(Setting the refresh interval to "30μs")
When unsupported memory is connected,
the system beeps and halts
When DRAM size = 0, halts
When it can not be used as stack area,
halts
When error is detected, halts
(Setting of boot status and IRT busy flag,
The rest bits are set to 0)
When a CMOS error is detected, it does
not resume
If "resume status code" is not set, no
resume occurs
[CONFIDENTIAL]
2 Troubleshooting
2-23

Advertisement

loading