4 Replacement Procedure
4.31 Fluorescent lamp
Fasten screws of the PCB and bezel
1. Fasten four screws. ((1) in the bellow figure)
N
・
CAUTION: 1. The tightening torque must be 0.147
m (1.5kgf
cm) for all the screws.
2. Use an insert bit of point size 0 for the Philips screwdrivers.
Figure 4-63 Replacing 12.1 Inch TMD fluorescent lamp (11)
4-92
[CONFIDENTIAL]
PORTEGE M400 Maintenance Manual (960-541)