Toshiba Portege R200 Maintenance Manual page 71

Personal computer
Hide thumbs Also See for Portege R200:
Table of Contents

Advertisement

2.5 USB FDD Troubleshooting
Procedure 2
Diagnostic Test Program Execution Check
Insert the Diagnostics Disk in the USB FDD of the computer, turn on the computer and run
the test. Refer to Chapter 3, Tests and Diagnostics, for more information about the
diagnostics test procedures.
Make sure the floppy disk is formatted correctly and that the write protect tab is disabled.
Floppy disk drive test error codes and their status names are listed in Table 2-5. If any other
errors occur while executing the FDD diagnostics test, go to Check 1.
Code
Check 1
If the following message is displayed, disable the write protect tab on the floppy
disk by sliding the write protect tab to "write enable". If any other message
appears, perform Check 2.
Write protected
Check 2
Make sure the floppy disk is formatted correctly. If it is, go to Procedure 3.
PORTEGE R200 Maintenance Manual (960-519)
Table 2-5 FDD error code and status
Status
01h
Bad command
02h
Address mark not found
03h
Write protected
04h
Record not found
06h
Media replaced
08h
DMA overrun error
09h
DMA boundary error
10h
CRC error
20h
FDC error
40h
Seek error
60h
FDD not drive
80h
Time out error (Not ready)
EEh
Write buffer error
FFh
Data compare error