Download Print this page
Nelson MPES69BWP Quick Start Manual

Nelson MPES69BWP Quick Start Manual

Security floodlight with pir sensor

Advertisement

Quick Links

17
1 Terminal Block
2 Cable Anchorage
3 Cable Gasket
4 Power Cable
5 Fixing Cover Screw( x 2)
6 Gasket Piece
7 Mounting Wall Screw ( x 2)
Fig.1C
Fig.1 B
LOWEST SENSITIVITY
HIGHEST SENSITIVITY
5. Use the plastic back plate to mark the position of screw holes onto
mounting surface.
Drill the wall to depth of about 4cm and fit the wall plugs (supplied) . Care
should be taken to avoid drilling or screwing into concealed electrical
wiring.
6. Connecting the power cable to the Terminal Block, see the relative
symbol in Fig.2, ensure the cable passes through the Cable Gasket.
7. Affix the back plate to the mounting surface with Mounting Wall Screws
(supplied).
8. Re-fit the Terminal Block and Cable Anchorage.
9. Re-fit the cover.
10. Insert the PAR38 bulbs (not supplied), please ensure the sealing rubber
(supplied), is placed on the lamp holder prior to installation of PAR38
lamp.
Important: loosen all lock nuts and screws on sensor and lamp holders
before making any adjustments.
2.5 Metres
INSTALLATION
For installation of the Security Light, please refer to Fig.2.
1. Installation by a licensed electrician and according to IEC wiring regulation.
2. Switch power off at the meter box and ensure that there is no power to the
light.
3. Unscrew the Fixing Cover Screws then remove the cover and Cable Gasket.
4. Remove the Cable Anchorage and Terminal Block.
Z
Blue (Power Cable)
r
Brown (Power Cable)
0 o 0 0
0 0
Blue(PIR Wire)
Brown(PIR Wire)
NELSON
Introduction
The Security Light incorporates a PIR (Passive Infra Red) sensing
device which continuously scans a preset operating zone and
immediately switches the light on when it detects movement in that
area.
This means that whenever movement is detected within range of the
sensor the light will switch on automatically to illuminate pathways,
steps, patios, porches or whatever area you have selected to light for
the reasons of safety, convenience or security. While there is
movement within the range of the unit the light will remain on.
WHERE TO FIT YOUR SECURITY LIGHT
To achieve best results, we suggest you take into account the
following points:
• Ideally the Security Light should be mounted 1.8 to 2.5 metres (6
to 8ft) above the area to be scanned (refer Fig.1A).
• To avoid damage to unit ,- do not aim the sensor towards the sun.
1111 To avoid nuisance triggering, the sensorshould be directed away
from heat sources such as barbecues, air conditioners, other
outside lighting, moving cars and flue vents
• To avoid nuisance triggering, keep away from areas of strong
electromagnetic disturbance..
• Do not aim towards reflective surfaces such as smooth white
walls, swimming pools, etc. The Security Light scanning
specifications (approximately 12 metres at 180° ) may vary slightly
depending on the mounting height and location. The detection range
of the unit may also alter with temperature change. Before selecting a
place to install your Security Light you should note that movement
across the scan area is more effective than movement directly
toward or away from the sensor. (refer Fig.1B). If movement is made
walking directly towards or away from the sensor and not across, the
apparent detection range will be substantially reduced. (refer Fig.1C)
• The MPES69BWP model sensor lamp may be mounted in a
position where the sensor is exposed to intermittent rain. Always
mount the MPES69B sensor light in a sheltered position. i.e. Under
the eaves of the house.
SECURITY FLOODLIGHT
with PIR SENSOR
Models: MPES69B & MPES69BWP
MPES69VVWP

Advertisement

loading

This manual is also suitable for:

Mpes69bMpes69vvwp