The oil fill cap/dipstick must be installed
IMPORTANT:
securely onto the tube at all times when the engine
is operating. Severe engine damage could result from
a failure to do so.
Start the tractor engine and allow it to run for thirty
seconds, then stop the engine and remove the
ignition key.
Check the oil level and add oil if necessary. Do not
overfill the engine crankcase.
Examine the area around the base of the oil fill
tube, the oil filter adapter, and the oil drain valve for
leaks before operating the tractor.
If leaks are present, have your engine
IMPORTANT:
serviced by a Toro dealer before operating the tractor.

Air Filter

The engine is equipped with a replaceable, high density
paper air cleaner element and an oiled, foam
precleaner. Always examine the air cleaner before
starting the engine. Check for a buildup of dirt and
debris around the air cleaner system. Keep this area
clean. Also check for loose or damaged components.
Replace all bent or damaged air cleaner components.
NOTE:
Starting the tractor with loose or damaged air
cleaner components could allow unfiltered air into the
engine causing premature wear and failure.
Precleaner
Wash and re-oil the precleaner every 25 hours of
operation if equipped, (more often under extremely
dusty or dirty conditions).
Loosen the air cleaner cover knob and remove the
cover.
Remove the precleaner.
Wash the precleaner in warm water with detergent.
Rinse the precleaner thoroughly until all traces of
detergent are eliminated. Squeeze out excess
water (do not wring). Allow the precleaner to air dry.
Saturate the precleaner with new engine oil.
Squeeze out all excess oil.
Reinstall the precleaner over the paper element.
Reinstall the air cleaner cover.
Service Paper Element
The paper element should be replaced at least every
100 hours of operation. Replace more frequently if the
tractor is operated under extremely dusty conditions.
To replace the paper element, proceed as follows:
Pivot the air cleaner cover upward and unhook the
wire latch which secures the element in place.
Remove the air cleaner element with precleaner.
Remove the precleaner from the element and
service as instructed earlier in this section.
Do not wash the paper element or use
IMPORTANT:
pressurized air, as this will damage the element.
Examine the element and discard if dirt and/or damage
is present.
NOTE:
Handle new elements carefully; do not use if
the sealing surfaces are bent or damaged.
If any loose dirt or debris fell on the air cleaner base
when the element was removed, carefully remove it
and wipe the base clean. Be careful that none of it
drops into the intake.
Check the air cleaner base. Make sure it is secured
and not damaged. Also check the air cleaner cover
for damage or improper fit. Replace all damaged air
cleaner components.
Install the precleaner over the new paper element
and reinstall the element.
Lower the wire latch to secure the element in place
and pivot the air cleaner cover downward.
Spark Plugs
Every 200 hours of operation, remove the spark plugs,
check condition, and reset the gap or replace with a
new plugs as necessary.
Lift the tractor’s hood and locate the spark plug wire
on the front, right area of the engine.
Carefully pull the spark plug wire boot off of the
spark plug.
Before removing the spark plug, clean the area
around the base of the plug to keep dirt and debris
out of the engine.
Using a ratchet with a 5/8-inch spark plug socket,
remove the spark plug and check its condition.
Replace the plug if worn, dirty or damaged. Reuse
only after resetting the gap as instructed.
NOTE:
Do not clean the spark plug in a machine
using abrasive grit. Some grit could remain in the spark
plug and enter the engine causing extensive wear and
damage.