Standard Features:
RoHS Compliant
Standard Double-P Quarter Brick Pinout
Size: 2.28" × 1.45" × 0.5"
(57.9mm × 36.8mm × 12.7mm)
Up to 50A of output current
Output power – up to 250W
Power density > 151W / in
Efficiency – up to 93.5%
Full load efficiency – 91.5%
70% of full load (35A) efficiency – 92.5%
Metal board design with high usable power
40A at 50°C, 200LFM, no heat sink
36A at 60°C, 200LFM, no heat sink
Wide output voltage trim range
Basic insulation – 1500Vdc
Negative remote on/off logic
Industry standard output voltage trim
Pre-bias startup capability
Remote sense
Constant switching frequency
UL 60950 (US and Canada), VDE 0805,
CB scheme (IEC950)
CE Mark (EN60950)
Latched output over-voltage protection
©2005-2006 TDK Innoveta Inc.
iQP 5V/50A Datasheet 8/3/2006
iQP Series –Single Output Quarter Brick
TM
3
Powereta™ iQP Series DC/DC Power Modules
The Powereta™ Series offers an industry
standard Double-P quarter brick high current
power module with true useable output
power. Its 91.5% full load efficiency (92.5%
at 35A/175W) and superior thermal
performance make the Powereta™ series of
power modules ideally suited for tight space
and power-hungry ATCA applications in
demanding thermal environments. This
rugged building block is designed to serve as
the core of your high reliability system. A
wide output voltage trim range, -20 to +10%,
and remote sensing are standard features
enhancing versatility.
Auto-recovery full protections:
o Input under and over voltage
o Output over-current
o Output short circuit
o Thermal limit
EMI: CISPR 22 A or B with external filter
Multiple patents
ISO Certified manufacturing facilities
Optional Features:
Positive remote on/off logic
2.79 mm (0.110") Thru-hole pins
4.57 mm (0.180") Thru-hole pins
Non-latching output OVP protection
Latched output over-current protection
Latched over-temperature protection
(877) 498-0099
48V Input, 5V / 50A /250W Output
Quarter Brick
1/15

Advertisement

Table of Contents
loading

Summary of Contents for TDK Powereta iQP 5V/50A

  • Page 1 CB scheme (IEC950) • CE Mark (EN60950) • Latched output over-voltage protection ©2005-2006 TDK Innoveta Inc. iQP 5V/50A Datasheet 8/3/2006 Powereta™ iQP Series DC/DC Power Modules The Powereta™ Series offers an industry standard Double-P quarter brick high current power module with true useable output power.
  • Page 2 TDK Innoveta, Inc. 3320 Matrix Drive, Suite 100 Richardson, Texas 75082 Phone (877) 498-0099 Toll Free (469) 916-4747 (877) 498-0143 Toll Free (214) 239-3101 support@tdkinnoveta.com http://www.tdkinnoveta.com/ ©2005-2006 TDK Innoveta Inc. iQP 5V/50A Datasheet 8/3/2006 Input Output Output Voltage Current/ Units Power 36-75V 050 –...
  • Page 3: Mechanical Specification

    On/Off Vin(-) Vo(-) Vo(-) Pin base material is copper or brass with matte tin plating; the maximum module weight is 60g (2.1 oz). ©2005-2006 TDK Innoveta Inc. iQP 5V/50A Datasheet 8/3/2006 1.02 [.040] DIA 1.52 [.060] DIA 2 pins 4 pins M3 X .5 threaded...
  • Page 4: Absolute Maximum Ratings

    Caution: The power modules are not internally fused. An external input line normal blow fuse with a maximum value of 15A is required; see the Safety Considerations section of the data sheet. ©2005-2006 TDK Innoveta Inc. iQP 5V/50A Datasheet 8/3/2006 Unit Notes &...
  • Page 5: Electrical Data

    Output Over Voltage Protection External Load Capacitance Isolation Capacitance Isolation Resistance Vref * Engineering Estimate † Contact TDK Innoveta for applications that require additional capacitance or very low ESR ©2005-2006 TDK Innoveta Inc. iQP 5V/50A Datasheet 8/3/2006 Unit 4.88 5.12 4.85 5.15...
  • Page 6: Electrical Characteristics

    Ch. 1: Vo Ch. 3: Io Start-up from Input Voltage Application at Full Load. Ch. 1: Vo Ch. 3: Io ©2005-2006 TDK Innoveta Inc. iQP 5V/50A Datasheet 8/3/2006 iQP48050A050V-000 through -0x9: 5V, 50A, 250W Output Output Current (A) Vin = 48V...
  • Page 7 Typical Output Voltage vs. Load Current at Ta=25C. Io_min = 0A Typical Output Voltage vs. Low Voltage Input Turn-on and Turn-off at Ta=25C ©2005-2006 TDK Innoveta Inc. iQP 5V/50A Datasheet 8/3/2006 iQP48050A050V-000 through -0x9: 5V, 50A, 250W Output Vin = 48V...
  • Page 8: Thermal Performance

    The thermal curves provided are based upon measurements made in TDK Innoveta’s experimental test setup that is described in the Thermal Management section. Due to the large number of variables in system design, TDK Innoveta recommends that the user verify the module’s thermal performance in the end application. The critical component should be thermo- coupled and monitored, and should not exceed the temperature limit specified in the derating curve above.
  • Page 9: Thermal Management

    This also results in a more conservative derating. ©2005-2006 TDK Innoveta Inc. iQP 5V/50A Datasheet 8/3/2006 The cross section of the airflow passage is rectangular with the spacing between the top of the module and a parallel facing PCB kept at a constant (0.5 in).
  • Page 10 With improved thermal performance, more power can be delivered at a given environmental condition. Standard heatsink kits are available from TDK Innoveta Inc. for vertical module mounting in two different orientations ©2005-2006 TDK Innoveta Inc. iQP 5V/50A Datasheet 8/3/2006 (longitudinal –...
  • Page 11: Operating Information

    2ms delay from the time an overload condition appears at the module output until the hiccup mode will occur. A latched over- current protection option is also available. Consult the TDK Innoveta technical support for details. Output Over-Voltage Protection: The power modules have a control circuit,...
  • Page 12 Where ∆%=100×(Vo,nom - Vdesired) / Vo_nom The current limit set point does not increase as the module is trimmed down, so the available output power is reduced. ©2005-2006 TDK Innoveta Inc. iQP 5V/50A Datasheet 8/3/2006 Vin (+) On/ Off Vin(-)
  • Page 13 220uF to 470uF/100V input electrolytic capacitors should be present if the source inductance is greater than 4uH. Reliability: The power modules are designed using TDK Innoveta’s stringent design guidelines for component derating, product qualification, and design reviews. Early failures are screened out by both burn-in and an automated final test.
  • Page 14 Contact TDK Innoveta technical support for guidance regarding proper handling, cleaning, and soldering of TDK Innoveta’s power modules. Input/Output Ripple and Noise Measurements: Vs Vs The input reflected ripple is measured with a current probe and oscilloscope. The ripple current is the current through a 12µH differential mode inductor, Lin, with esr ≤...
  • Page 15: Safety Considerations

    No license is granted by implication or otherwise under any patent or patent rights of TDK Innoveta. TDK Innoveta components are not designed to be used in applications, such as life support systems, wherein failure or malfunction could result in injury or death.