Single Slot USB/Serial Cradle

Troubleshooting the Single Slot USB/Serial Cradle
Table 6-3
Symptom
Possible Cause
LEDs do not
Cradle is not receiving
light when EDA
power.
or spare battery
EDA is not seated firmly
is inserted.
in the cradle.
Spare battery is not
seated firmly in the
cradle.
EDA battery is
EDA was removed from
not charging.
cradle or cradle was
unplugged from AC
power too soon.
Battery is faulty.
The EDA is not fully
seated in the cradle.
Ambient temperature of
the cradle is too warm.
Spare battery is
Battery not fully seated
not charging.
in charging slot.
Battery inserted
incorrectly.
Battery is faulty.
Ambient temperature of
the cradle is too warm.
During data
EDA removed from
communication,
cradle during
no data
communications.
transmits, or
Incorrect cable
transmitted data
configuration.
was incomplete.
Communication software
is not installed or
configured properly.
Ensure the power cable is connected securely to both the cradle and to
AC power.
Remove and re-insert the EDA into the cradle, ensuring it is firmly
seated.
Remove and re-insert the spare battery into the charging slot, ensuring
it is firmly seated.
Ensure cradle is receiving power. Ensure EDA is seated correctly.
Confirm main battery is charging under Start - Settings - System -
Power. The standard capacity battery (1900 mAh) fully charges in less
than four hours. The extended capacity battery (3800 mAh) fully
charges in less than eight hours.
Verify that other batteries charge properly. If so, replace the faulty
battery.
Remove and re-insert the EDA into the cradle, ensuring it is firmly
seated.
Move the cradle to an area where the ambient temperature is between
o
o
0
C and 35
C.
Remove and re-insert the spare battery in the cradle, ensuring it is
firmly seated.
Re-insert the battery so the charging contacts on the battery align with
the contacts on the cradle.
Verify that other batteries charge properly. If so, replace the faulty
battery.
Move the cradle to an area where the ambient temperature is between
o
o
0
C and 35
C.
Replace EDA in cradle and retransmit.
See the system administrator.