NWZ-A826/A826K/A828/A828K/A829
4-1-3. Standby current check
This mode is used in case standby current is checked.
Checking method:
1. Enter the test mode.
2. Press the [
]/[
] key to select the “POWER”, and press the
v
V
[
] key to enter the minor item.
B
3. Press the [
]/[
] key to select the “DSVCHK”.
v
V
4. Press the [
] key, enter the state of the deep sleep.
u
5. Press the [BACK] key, release the state of the deep sleep.
liquid crystal display
POWER DSVCHK
OK
6. Press the [BACK] key, return to minor item selection screen.
4-1-4. Charge current check
This mode is used in case charge current is checked.
Checking method:
1. Enter the test mode.
2. Press the [
]/[
] key to select the “POWER”, and press the
v
V
[
] key to enter the minor item.
B
3. Press the [
]/[
] key to select the “CHGCHK”.
v
V
4. Press the [
] key, the charge setting is displayed.
u
liquid crystal display
POWER CHGCHK
AC
AC
5. In this state, each time the [OPTION] key is pressed, the port
setting for the charge is changed as shown in the table below.
Port control
Display
CHG_XCHGEN
CHG_PEN1
CHG_PEN2
AC
L
H
H
USB500
L
H
H
USB100
L
H
L
6. Press the [BACK] key, return to minor item selection screen.