Fluke 700HPPK Instructions Manual

High pressure pneumatic test pump
Hide thumbs Also See for 700HPPK:

Advertisement

Quick Links

Introduction
The Fluke 700HPP High Pressure Pneumatic Test Pump
(the Product) is a portable device that produces precise
pressures up to 21 MPa (3000 psi). The 700HPPK (the
Kit) includes the Product and a High Pressure Calibration
Manifold (HPM) with hose.
Contact Fluke Calibration
To contact Fluke Calibration, call one of the following
telephone numbers:
Technical Support USA: 1-877-355-3225
Calibration/Repair USA: 1-877-355-3225
Canada: 1-800-36-FLUKE (1-800-363-5853)
Europe: +31-40-2675-200
Japan: +81-3-6714-3114
Singapore: +65-6799-5566
China: +86-400-810-3435
Brazil: +55-11-3759-7600
Anywhere in the world: +1-425-446-6110
To see product information or download manuals and the
latest manual supplements, visit Fluke Calibration's
website at
www.flukecal.com.
To register your product, visit
product.
Safety Information
A Warning identifies conditions and procedures that are
dangerous to the user. A Caution identifies conditions and
procedures that can cause damage to the Product or the
equipment under test.
Warning
To prevent personal injury:
Read all safety information before you use
the Product.
Use the Product only as specified, or the
protection supplied by the Product can be
compromised.
Carefully read all instructions.
Do not use the Product if it operates
incorrectly.
Do not use the Product if it is altered or
damaged.
Disable the Product if it is damaged.
Do not attempt to operate the Product above
its rated pressure.
PN 4784850
September 2016
© 2016 Fluke Corporation, All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective
companies.
High Pressure Pneumatic Test Pump
http://flukecal.com/register-
Avoid tipping the Product so that it will fall
over.
Use care when working with this Product. Do
not drop the Product or strike it with sharp
objects.
Carefully follow the cleaning and
decontamination instructions in the manual.
Do not use unapproved solvents or cleaners
on the product.
Symbols
The symbols shown in Table 1 are found in these
instructions or on the Product.
Table 1. Symbols
Symbol
WARNING.RISK OF DANGER.

Consult user documentation.
Certified by CSA Group to North American safety
standards.
Conforms to European Union directives.
Conforms to relevant Australian Safety and EMC

standards.
This product complies with the WEEE Directive
marking requirements. The affixed label indicates
that you must not discard this electrical/electronic
product in domestic household waste. Product
Category: With reference to the equipment types in
the WEEE Directive Annex I, this product is classed
as category 9 "Monitoring and Control
Instrumentation" product. Do not dispose of this
product as unsorted municipal waste.
700HPPK
Instructions
Definition

Advertisement

loading

Summary of Contents for Fluke 700HPPK

  • Page 1 Disable the Product if it is damaged. • Do not attempt to operate the Product above its rated pressure. PN 4784850 September 2016 © 2016 Fluke Corporation, All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies.
  • Page 2: Box Contents

    (700HPPK only). Use any approved (properly-rated) adapter as required. Close the upper vent valve (700HPPK) and slowly pressurize the pump/gauge system to 21 MPa (3000 psi, 210 bar). Maintain pressure for 60 seconds.
  • Page 3: Operation

    Fold the pump base and place in the bag.  700HPPK Operation  To operate the pump and calibration manifold: O-Ring The 700HPPK can be operated with the calibration  Ball bearings manifold attached as shown in Figure 1 or detached  for easier operation.
  • Page 4: Maintenance

    10. Use the vent valve on the calibration manifold to Clean the Calibration Manifold (700HPPK Only) slowly reduce pressure. Use the pump to increase To clean the calibration manifold: pressure to move to the next pressure reading. Keep Remove the hose that connects the calibration the inlet valve closed if the pump is not being used.
  • Page 5 Quick Service For quick service of pump, perform steps 1 through 7 from Lubricate the Pump before you do the steps below. To replace the piston seal, see Figures 1, 2 and Table 3: With the pump handle removed from the Lubricate the Pump procedure, use a 20 mm wrench to unscrew ...
  • Page 6: Specifications

    LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for one year from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling.

This manual is also suitable for:

700hpp-bsp700hpp-met700hppk-bsp700hppk-met