UPS Uninterruptible Power Supply User Manual P73220uk...
Page 2
Important Safety Instructions Thank you for purchasing the Belkin Uninterruptible Power Supply (UPS). It will provide you with the best protection for your connected equipment. Please read this manual! This manual provides safety, installation and operating instructions that will help you obtain the highest performance and service life that the UPS has to offer.
Typical "Stand-by" UPS units do not have AVR to increase the output voltage or decrease the output voltage to your computer. A surge protector can only protect your computer from over-voltages due to irregular power. Belkin UPS units protect against surges, spikes, swells, line-noise, brownouts and blackouts! Only a Belkin UPS with AVR can give your computer clean and consistent power at all times.
• The internal energy source (the battery) cannot be de-energised by the user. The output may be energised when the unit is not connected to a main power supply, thus a shock hazard may be present.
FRONT PANEL Different LEDs on the front panel will signal information when various conditions occur: ON LINE ON BATTERY OVERLOAD REPLACE BATTERY ON/OFF/TEST/SILENCE BUTTON Press the button more than 3 seconds to turn the UPS on or off, press the button less than 3 seconds to activate the UPS self-testing or to silence the back up alarm.
Presentation REAR PANEL INTERFACE PORT Provides both USB support DOS , Windows ® TELEPHONE/FAX/MODEM OR 10Base-T NETWORK PROTECTION Telephone/Fax/Modem lines are surge protected and provide complete safety for Internet connection. One input port be protected (i.e. Modem and fax). BATTERY REPLACEMENT DOOR (HOT-SWAPPABLE BATTERY) AC INPUT POWER RECEPTACLE AC BREAKER (CIRCUIT BREAKER) The circuit breaker button will stick out if an overload condition forces the UPS to discon-...
Page 8
Presentation (continued) 4.11 Surge-Only Protected outlets 4.10 Battery Back-up outlets 4.5 Interface Port USB or RS232 (Depending on model) 4.8 AC Input Power Receptacle 4.6 Telephone/Fax/Modem or 10 base T network Protection 4.9 AC Breaker (Circuit Breaker) 4.7 Battery Replacement Door...
This may overload the UPS. NOTE : Additional AC Power Cables 1.8M (6ft) (Part No. F3A102b06) are available for connecting additional loads to the UPS. Please contact Belkin Components for details of a local reseller.
CAUTION: This surge protection device is for indoor use only. Never install telephone wiring during a lightning storm. Charge the Battery The UPS charges its battery whenever it is connected to the utility power. For best results, charge the battery for 4 hours prior to initial use.
BACK-UP (slow alarm) When in "BACK-UP" mode, the on battery sounds an audible alarm every 15 seconds. The alarm may be disabled using the Belkin Sentry Bulldog Shutdown Management Software or as stated in step 6.3. The alarm stops when the UPS returns to line normal operation.
Software Options USB (Universal Serial Bus): HID (Human Interface Device) setup procedure 8.2.1 When the USB cable that comes with the UPS is first connected to a USB port on your computer, the Windows should appear automatically. (To display this dialog manually, you can choose the Start button and then Settings to access the Control Panel and then double-click on ADD NEW HARDWARE.
Page 13
USB Interface Port Firmware ...Version Of Firmware Rating VA ...Rated Power Capacity Of UPS Rating Voltage ...Rated Power Voltage Of UPS Rating Frequency...Connected Frequency Rating Of UPS Rating Battery Voltage ...Rated Battery Voltage Used By UPS Input frequency...AC Utility Frequency Input voltage ...AC Utility Voltage Output source...Indicating Bypass or On Battery Alarm ...To Set Situation For Alarm...
RS232 Pin definition: NC ...1 TXD...2 RXD ...3 NC ...4 Signal Ground ..5 *pin2: PC receives line RS232 data from UPS. *pin3: PC transmits line RS232 data to UPS. *pin5: signal ground. *other: not used. The RS232 communication port provides the following features. 1.
The average life of a battery is 3-5 years before ever needing to be replaced. 11.0 EcoBattery Replacement Program In the event that the UPS needs a battery replacement, Belkin offers its EcoBattery Replacement Program. This program offers a battery replacement and full service check on your UPS to ensure it is working properly to protect your connected devices.
Page 16
Battery Replacement Refer Servicing to qualified service personnel or contact Belkin Components. Diagram b Slide the battery compartment cover. Diagram c Slide the battery partially out (continued) Diagram a Diagram d Slide the battery back in. Avoid pinching the wires.
PROBLEM UPS not on LED not lit UPS always at battery mode Back up time too short The UPS continuously beeps Red LED lit 13.0 Storage Conditions Store the UPS covered and upright in a cool, dry location, with its battery fully charged. Before storing, charge the UPS for at least 4 hours.
Specifications (RS232 Series) MODEL INPUT Capacity Voltage Frequency OUTPUT Voltage (on battery) Frequency (on battery) Voltage Regulation Transfer Time Spike Protection PROTECTION Overload Protection AND FILTERING Unit Input Modem/Network Short Circuit Type BATTERY Typical Recharge Time Protection Back up Time Full/half load Net Weight PHYSICAL...
Specifications (USB Series) MODEL INPUT Capacity Voltage Frequency OUTPUT Voltage (on battery) Frequency (on battery) Voltage Regulation Transfer Time Spike Protection PROTECTION Overload Protection AND FILTERING Unit Input Modem/Network Short Circuit Type BATTERY Typical Recharge Time Protection Back up Time Full/half load Net Weight PHYSICAL...
Belkin Components warrants this product against defects in materials and workmanship for two years. If a defect is discovered, Belkin will, at its option, repair or replace the product at no charge, provided it is returned during the warranty period, with transportation charges prepaid, to Belkin Components following the procedure specified in the warranty sheet.