Download Print this page

Sennheiser MKH MKH 50-P48 User Manual

Rf symmetrical capsule condenser microphone

Advertisement

Quick Links

MKH 50 P 48
Microphones |
General Description
The super-cardioid MKH 50 offers a higher attenuation of diffuse-field
and lateral sound than the cardioid microphone. It is principally designed
for use as a soloist's or spot microphone for applications requiring a high
degree of side-borne sound muting and feedback rejection. The direc-
tional characteristics are frequency-independent.
Cable pictured is an accessory not supplied with the microphone
Features
High rejection of lateral sounds
Exceptionally low inherent self-noise
Transformerless and fully floating balanced output
Symmetrical transducer technology ensures extremely low distortion
Switchable roll-off filter to compensate for proximity effects
at a distance of approx. 0.5 m
Switchable pre-attenuation
Black, anodised light metal body
Delivery includes: 1 MKH 50, 1 MZS 40 shock mount,
1 MZW 41 windshield
Recommended Accessories
MZA 14 P 48 U battery power supply unit
MZT 441 table stand
MZT 100table stand
MZD 30 dual clip, for MS stereo
MZB 415 fish pole
MZS 40 shock mount
MZW 41 foam windshiel
MZP 40 popshield
MZS 20-1 shock mount
MZW 20-1 basket windshield
MZH 20-1 hairy cover
RF Symmetrical Capsule
Condenser Microphone
Cat. No. 002960
Cat. No. 000799
Cat. No. 001883
Cat. No. 002990
Cat. No. 000972
Cat. No. 003017
Cat. No. 029681
Cat. No. 003132
Cat. No. 003609
Cat. No. 003606
Cat. No. 003610
Technical Data
Pick-up pattern ...........................................................super-cardioid
Frequency response ................................................. 40 – 20,000 Hz
Sensitivity (free field, no load, 1 kHz)........ 25 (8) mV/Pa ± 1 dB
Nominal impedance ................................................................. 150 Ω
Min. terminating impedance ..................................................... 1 kΩ
Equivalent noise level
A-weighted (DIN IEC 651)............................................... 12 (18) dB
CCIR-weighted (CCIR 468-3)........................................... 21 (27) dB
Max. sound pressure level ......................... 134 (142) dB at 1 kHz
Power supply ........................................................phantom 48 ± 4 V
Supply current............................................................................. 2 mA
Dimensions ................................................................ Ø 25 x 153 mm
Weight ...........................................................................approx. 100 g
Values in parentheses with attenuator switched on (–10 dB)
Effect of switchable roll-off filter
Profile
Super-cardioid studio directional microphone with switchable
pre-attenuation and switchable roll-off filter. Frequency
response 40 Hz – 20,000 Hz, sensitivity (free field, no load)
25 (8) mV/Pa ± 1dB at 1 kHz, nominal impedance 150 Ω,
min. terminating impedance 1 kΩ, equivalent noise level
A-weighted 12 (18) dB, CCIR-weighted 21 (27) dB, max. SPL
134 (142) dB at 1 kHz, phantom powering 48 ± 4 V, supply
current 2 mA, dimensions Ø 25 x 153 mm, weight approx. 100 g.
Values in parentheses with attenuator switched on (–10 dB).
Cat. No. 003109