Sennheiser e965 Instruction Manual

Sennheiser e965 Instruction Manual

Sennheiser 965 microphone instruction manual
Hide thumbs Also See for e965:

Advertisement

965
Produktname
Bedienungsanleitung
Instruction Manual
Notice d'emploi
Istruzioni per l'uso
Instrucciones de uso
Gebruiksaanwijzing

Advertisement

Table of Contents
loading

Summary of Contents for Sennheiser e965

  • Page 1 Produktname Bedienungsanleitung Instruction Manual Notice d‘emploi Istruzioni per l‘uso Instrucciones de uso Gebruiksaanwijzing...
  • Page 3: Table Of Contents

    Sennheiser a world-leading company in this field. Please take a few moments to read these instructions carefully, as we want you to enjoy your new Sennheiser products quickly and to the fullest.
  • Page 4: Safety Information

    “Safety information”, • using the microphone within the operating conditions and limitations described in this instruction manual. • using the microphone with care and storing it in a clean, dust- free environment. • not exposing the microphone to extreme temperatures. •...
  • Page 5: Delivery Includes

    Delivery includes 965 microphone 1 MZQ 800 microphone clamp 1 Pouch 1 Instruction manual 1 Warranty certificate...
  • Page 6: The 965 Microphone

    965 microphone 965 is a fully professional true condenser vocal microphone utilising the very best in condenser microphone technology to achieve new standards of quality and sound. An extended dynamic range and a super-smooth frequency response deliver an outstanding signal quality with excellent vocal projection and the lowest possible distortion.
  • Page 7: Product Overview

    Product overview Sound inlet basket XLR-3M connector » Directivity switch Sensitivity switch Bass roll-off switch...
  • Page 8: Connecting The Microphone

    Connecting the microphone Use a microphone cable with XLR-3 female connector to connect the microphone’s XLR-3 male connector microphone preamplifier. The microphone preamplifier must provide 48 V phantom powering. Pin assignment of the XLR-3 connector symmetrisch to the 6,3 mm...
  • Page 9: Using The Microphone

    Using the microphone CAUTION! Danger of damage to the microphone! The switches on the microphone can be damaged if you try to operate them using tools. Only using your fingers. Unscrewing the sound inlet basket Unscrew the sound inlet basket in order to have access to the following moisture-protected switches: •...
  • Page 10: Adjusting The Pick-Up Pattern (Cardioid/Super-Cardioid)

    Use the directivity switch to select the desired setting: : cardioid : super-cardioid Notes: In order to prevent feedback and crosstalk, postion your monitor loudspeakers in the angle area of the highest cancellation of the microphone (cardioid: 180°; super-cardioid: 135°). »...
  • Page 11: Adjusting The Sensitivity

    Cardioid Adjusting the sensitivity When very high signal levels cause distortion in the microphone or in the subsequent microphone preamplifier, you can reduce the microphone sensitivity. The sensitivity can be reduced by 10 dB. Use the sensitivity switch...
  • Page 12: Switching The Low-Cut Filter On/Off

    Switching the low-cut filter on/off In order to effectively reduce low-frequency pop or wind noise, you can switch in the low-cut filter (bass roll-off). Use the low-cut filter switch to select the desired setting: : low-cut filter off : low-cut filter on...
  • Page 13: Positioning The Microphone

    • • • • • • If sibilance or “popping” occurs, position the microphone slightly to the side and not directly in front of the mouth. High proximity effect (large bass boost) Powerful, direct sound Less proximity effect (less bass boost)
  • Page 14: Overview Of Microphone Applications

    Overview of microphone applications Variant Application Vocals Choirs Studio, acoustic instruments Orchestra Trumpet, trombone Saxophone Acoustic guitar Acoustic bass Guitar amplifiers Bass amplifiers x x x x Leslie Piano, grand piano Kick drums Snare drums Rack toms Floor toms Congas...
  • Page 15 Variant Application Cymbals Percussion Overheads Conference table, altar Lectern Theater stage x x x x...
  • Page 16: Care And Maintenance

    Use a soft, slightly damp cloth to clean the microphone. Do not use any solvents or cleansing agents. To clean the microphone’s sound inlet basket from time to time, proceed as follows: Unscrew the sound inlet basket from the microphone (see “Unscrewing the sound inlet basket”...
  • Page 17: Specifications

    Equivalent noise level A-weighted (DIN IEC 651) Phantom powering Connector Temperature range Weight Dimensions externally polarized dual diaphragm AF condenser microphone 25.4 mm/1" 40 to 20,000 Hz cardioid/super-cardioid, switchable 7 mV/Pa 2.3 mV/Pa approx. 50 Ω 142 dB 152 dB 21 dB 48 V/3.5 mA...
  • Page 18: Polar Diagrams And Frequency Response Curves

    Polar diagrams and frequency response curves Cardioid polar diagram Cardioid frequency response curve 1 0 0 1 0 0 Low Cut 1 .0 0 0 2 0 0 5 0 0 1 0 .0 0 0 1 0 k 2 0 k...
  • Page 19 Super-cardioid polar diagram Super-cardioid frequency response curve 1 0 0 1 0 0 Low Cut 1 .0 0 0 2 0 0 5 0 0 1 0 .0 0 0 1 0 k 2 0 k...
  • Page 20: Manufacturer Declarations

    Manufacturer Declarations Warranty 2 years CE Declaration of Conformity Sennheiser electronic GmbH & Co. KG declare that this device is in compliance with the applicable CE standards and regulations. Before putting the device into operation, please observe the respective countryspecific regulations!
  • Page 21 Sennheiser electronic GmbH & Co. KG Am Labor 1 30900 Wedemark, Germany Phone +49 (5130) 600 0 Printed in Germany Fax +49 (5130) 600 300 Publ. 04/08 www.sennheiser.com 524141/A01...

This manual is also suitable for:

E 965 - 04-08

Table of Contents