TROUBLESHOOTING

Problem:
Possible cause:
Gate does not lock
No power
Gate locks, but can be
Poor contact between
easily forced open
electromagnet and
armature plate
Incorrect voltage setting
Delay in gate releasing
A secondary diode was
installed across the
electromagnet
REGULAR MAINTENANCE
• Clean the contact surfaces of the electromagnet or armature plate with a soft cloth and non-abrasive, non-corrosive cleaner.
• Apply a light coat of a silicon lubricant to both contact surfaces and wipe away the excess to prevent rust.
• Check that the armature plate is securely attached to the bracket, yet can pivot slightly around the armature screw.
• Check that the electromagnet is securely attached to the bracket.
UL CERTIFICATION
Electromagnetic lock only (Model E-942FC-1300/E-942FC-600) conforms to UL/10B
"Fire Tests of Door Assemblies" and UL/10C "Positive Pressure Fire Tests of Door Assemblies" for swinging door assemblies. It is
also classified in accordance with the Uniform Building Code standard 7-2.
WARRANTY:
This SECO-LARM product is warranted against defects in material and workmanship while used in
normal service for a period of one (1) year from the date of sale to the original consumer customer. SECO-LARM's obligation is
limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM.
This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair,
or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such
equipment is not operating properly as a result of causes other than defects in material and workmanship.
The sole obligation of SECO-LARM, and the purchaser's exclusive remedy, shall be limited to replacement or repair only, at
SECO-LARM's option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal
or property damages of any kind to the purchaser or anyone else.
NOTICE
The information and specifications printed in this manual are current at the time of publication. However, the SECO-LARM
policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right to change
specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors.
Copyright © 2007 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or
in part, without the written permission of SECO-LARM.
SECO-LARM
U.S.A., Inc.
®
16842 Millikan Avenue, Irvine, CA 92606
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326
Page 4
Solutions:
• Check to make sure the wires are secure
• Check that the power supply is connected
and operating
• Make sure the unit is wired correctly
• Make sure the electromagnet and armature
plate are properly aligned
• Make sure the contact surfaces of the
electromagnet and armature plate are
clean and free from rust
• Check the power leads with a meter, and
make sure the correct voltage is present
• The electromagnet is fitted with a metal
oxide varistor to prevent interference, so do
not install a secondary diode
FILE: DT/DTP/IM_E-942FC-xxxS.pmd
ORDER PART# 764-024%_077
PITSW1
Website: www.seco-larm.com
E-mail: sales@seco-larm.com
SECO-LARM U.S.A., Inc.
Magnetic Gate Lock Bracket Installation Manual
Installation Manual
ENFORCER
E-942FC-1K3SQ
E-942FC-600SQ
Electromagnetic Lock with
Weldable Brackets for Gates
• For most types of outdoor sliding and swinging electric gates.
• Includes a magnetic lock with brackets for armature and magnet.
• Brackets can be welded or bolted directly to gate.
• Holding force: E-942FC-1K3SQ – 1,300 pounds (591kg).
E-942FC-600SQ – 600 pounds (272kg).
• Brackets are zinc-plated for corrosion resistance.
• Brackets have black finish to match most gates.
• Water- and vandal-resistant attractive stainless-steel finish.
• Maintenance-free, factory-sealed design.
• Fail-safe operation (unlocks door if power is removed).
• Mounted vertically.
• Four knockouts on the junction box.
• Adapter and mounting hardware included.
• Voltage — 12VDC or 24VDC. Prewired for 12VDC operation.
• Current draw — 500mA @ 12VDC (250mA @ 24VDC).
MOUNTING THE ELECTROMAGNETIC LOCK
A. Determine type of gate:
1. Single-swing gate — Gate swings on one end, and comes to rest on a fixed gate post when closed. In this
case, a typical installation has the electromagnet fixed to the gate post, and the armature connected to the free end
of the gate.
2. Double-swing gate — Two gates swing in the same direction when activated. The electromagnet is fixed to the
free end of one gate, and the armature is fixed to the free end of the other.
3. Sliding gate — The gate slides instead of swings away from a fixed gate post. A typical installation has the
electromagnet fixed to the gate post, and armature connected to the free end of the gate.
B. Mount the electromagnet — In most cases, the position of the electromagnet will determine the location of the
armature plate. Make sure there is space to run the cable.
1. Tack weld bracket into place. (Tack weld only.)
2. Dismount the electromagnetic lock from the bracket. Warning: Failure to remove electromagnetic lock will
result in severe damage to lock. Weld 3 or 4 beads about 1" apart. Make sure not to weld the junction box.
(See diagram for "No Weld" areas.)
3. Remount the electromagnetic lock.
®
E-942FC-1K3SQ Shown
(Magnetic lock only)
Page 1

Advertisement

loading

Summary of Contents for ENFORCER Enforcer E-942FC-600SQ

  • Page 1: Troubleshooting

    UL CERTIFICATION Electromagnetic lock only (Model E-942FC-1300/E-942FC-600) conforms to UL/10B “Fire Tests of Door Assemblies” and UL/10C “Positive Pressure Fire Tests of Door Assemblies” for swinging door assemblies. It is also classified in accordance with the Uniform Building Code standard 7-2.
  • Page 2 C. Mount the armature — 1. Once the electromagnet is mounted, determine the armature bracket location and tack weld into place. (Tack weld only.) 2. Dismount the armature plate from the bracket. Warning: Failure to remove the armature plate from the bracket will damage the armature and rubber washer.

This manual is also suitable for:

E-942fc-1k3sqE-942fc-600sq