BEFORE INSTALLING, READ ENTIRE INSTRUCTIONS CAREFULLY.
RISK OF INJURY TO PERSONS FROM HAZARDOUS MOVING PARTS. SERIOUS INJURY POSSIBLE IF
NOT PROPERLY INSTALLED WITH A HOPPER OR A CONE SPECIFIED IN THE INSTRUCTION MANUAL.
FIG. 1
No. 9T
SPRAY
RINSE
APPROX.
No. 6T
30"
9" MIN.
6" MIN.
APPROX. 14"
6-5/8"
2" TO 4"
A
6"
IF YOU ARE REPLACING AN OLD DISPOSER GO TO MOUNTING DISPOSER
INSTALLATION OF CONE SINK INTO DISH OR WORKTABLE
1. (See Figures 1 and 2.) Locate hole center as shown on Figure 2. Cut a "C" (Figure 2) diameter hole in dish or work table, a minimum of 2"
from the inside front edge (operator's side). Hole can be cut with a "nibbler" after a knockout hole 1-1/2" diameter has been punched.
2. Lift cone to underside of table with cone flange overlapping all around (Figures 1 and 3).
3. Check alignment of cone spray fittings to be sure they are in the proper position. For 15" and 18" cones, position such that holes are located
to right and left side of operator. (See Figure 7 for location.)
4. Tack weld, spot weld, bolt, or rivet flange of cone sink to underside of dish or work table. If bolted or riveted, smooth top surface and wash-
solder around bolt or rivet heads and sand smooth.
5. Bead weld or solder and wash-solder all around where the table joins flange of cone sink for a clean, watertight, sanitary installation.
6. The cone sink has been designed with the step, as shown in Figure 3. In the welding or soldering operation required to assemble the cone
sink to the dish or work table, every attempt should be made to keep the recessed, flat portion of the cone free of the welded or solder mate-
rial. This will minimize the clean-up time required and provide a smooth, flat surface for any cover.
SPRAY-RINSE INSTALLATION
1. Locate center (Figures 1 and 2).
2. Drill 7/16" diameter hole through center.
3. Assemble 7/8" punch and tighten bolt head, as shown in
Fig. 4, until the die pierces the stainless steel, leaving a
clean opening of 7/8".
4. Place body valve and base in position, assemble washer
and locknut as shown in Figure 5.
5. Attach vol-temp assembly to the projecting nipple, as
shown in Figure 7.
MOUNTING DISPOSER
For models to be installed in sink with 3-1/2" outlet,
see separate sheet enclosed for mounting instructions.
1. Clamp ring taped to top side of Hush Cushion
top flange of Hush Cushion
and insert six screws also contained in plastic bag. Insert through clamp ring and
Hush Cushion
from the underside.
®
2. Line up holes in loose steel clamp ring on cone sink with screws in Hush Cushion
and raise disposer into position with screws matching holes in clamp ring in approximate
position with plumbing drain outlet.
3. To manually raise the disposer into position, lift the unit by grasping the disposer with
one hand from the bottom of the motor, and with the other hand around the Hush
Cushion
, guide the unit into position, as shown in Figure 6.
®
FIG. 2
B
SPRAY
RINSE
HOLE
FIG. 3
®
should be placed on underside of
®
. Line up holes in clamp ring with holes in Hush Cushion
INSTALLATION
INSTRUCTIONS
A
SINK
HOLE
C DIA.
DISH TABLE
CONE SINK
FIG. 4
7/8" PUNCH
®
®
COMMERCIAL
DISPOSER MODELS
500, 750, 1000,
1250, 1500
MODEL 6T
2216
2215
12" CONE
15" CONE
1
3
A
10
/
"
11
/
"
4
4
1
1
B
3
/
"
3
/
"
2
2
1
1
C
13
/
"
16
/
"
2
2
MODEL 9T
2216
2215
12" CONE
15" CONE
7
7
A
12
/
"
12
/
"
8
8
1
5
B
6
/
"
4
/
"
8
8
1
1
C
13
/
"
16
/
"
2
2
FIG. 5
CONE SINK
FIG. 6
2211
18" CONE
1
13
/
"
4
1
3
/
"
2
1
19
/
"
2
2211
18" CONE
7
12
/
"
8
1
3
/
"
8
1
19
/
"
2
BODY VALVE
BASE
WASHER
LOCKNUT
LOCKNUT
CO
NUT
N
CLAMP RING
CLAMP RING
MOUNT SCREW
HUSH CUSHION

Advertisement

loading

Summary of Contents for Waste King 500

  • Page 1 COMMERCIAL DISPOSER MODELS INSTALLATION 500, 750, 1000, INSTRUCTIONS 1250, 1500 BEFORE INSTALLING, READ ENTIRE INSTRUCTIONS CAREFULLY. RISK OF INJURY TO PERSONS FROM HAZARDOUS MOVING PARTS. SERIOUS INJURY POSSIBLE IF NOT PROPERLY INSTALLED WITH A HOPPER OR A CONE SPECIFIED IN THE INSTRUCTION MANUAL.
  • Page 2 Under such conditions, additionally, a larger size cold water line, larger solenoid valves and larger syphon breakers should be used to overcome potential stoppages. (Parts and data available from factory.) *Minimum cold water flow rate used with Models 500 through 1500: 5 gallons per minute or enough to push waste through pipeline into the sewer.
  • Page 3: Electrical Connections

    All electrical connections must be made in accordance with local wiring codes Flexible BX cable should be used in making electrical connections to motor to avoid transmission of noise. Be careful not to pinch wires when replacing terminal box. IMPORTANT! THE WASTE KING COMMERCIAL DISPOSER MUST BE CAREFULLY AND PERMANENTLY GROUNDED. GROUND SCREW IS PROVIDED.
  • Page 4 UNITS WITH MANUAL SWITCH VALVE MODEL VOLTS WK PART NO. CLOCKWISE WHITE WIRE POWER SUPPLY - ROTATION FUSE PER 110-120 HOT WIRE 500 – LOCAL CODE 2420 POWER “IN” 1500 220-240 TURNTABLE ROTATION JUNCTION CLOCKWISE AS VIEWED FROM THE TOP ROTATION NOTES:...
  • Page 5 THIS IS IMPORTANT. A Time Delay Kit to automatically continue water flow for a given period of time after the unit is turned off is available through authorized Waste King Service Agencies.
  • Page 6: Installation Instructions

    GUIDELINES FOR INSTALLATION FIELD CONSTRUCTED INSTRUCTIONS ENCLOSURES BEFORE INSTALLING, READ ENTIRE INSTRUCTIONS CAREFULLY (PER U.L. 430) FOR UNREINFORCED FLAT SURFACES: CAST METAL: ......NOT LESS THAN 1/8” (3.2 mm) THICK MALLEABLE IRON: .