TO INSTALL: Plumbing

Free Standing Cabinet, Pump Model:
1. Remove the kickplate and control box cover.
2. Route the water supply, which should be a 1/4"
O.D. copper tube through the back of the cabinet
to the front.
3. Install a flare nut and flare the end of the tube.
4. Flush the water line and fasten the flare nut to
the male flare on the inlet water valve.
5. Locate the coil of 3/8" ID plastic drain tubing
secured to the back of the cabinet.
Air Gap Device
(Where Required)
Drain
Connection
Water Shut
Off Valve
Water Filter
(Recommended)
6. Route the plastic drain tubing to the drain point
connection. Do not connect to a drain/waste line
below a trap. Connect the discharge line to the
drain, per local codes. An air gap will likely be
required between the ice machine drain tube and
the drain/waste receptacle.
7. Turn on the water and plug in the ice machine.
Pour a couple quarts of water in the bin, the drain
pump should start. Check for water leaks.
8. Replace the kickplate and control box cover.
9. Level the unit using the leg levelers.
ALL PLUMBING MUST MEET LOCAL CODES
THE DCE33 WILL FIT IN A SPACE
THE DEPTH OF THE CABINET IS 22" TO
THE FRONT EDGE OF THE HANDLE.
September 2011
Page 7
15
" WIDE X 33
" HIGH.
1
3
4
4
WATER AND DRAIN
INSTALLATION
Drain Tube
From Back Of
Machine
Water Inlet Connection
DCE33