Download Print this page

Scientific Atlanta Rosa Specification Sheet

Element management system

Advertisement

Quick Links

Network Management
ROSA™ EM - Element Management System
Description
The ROSA
Element Manager (EM) is specifically designed
to cost effectively monitor and control the transmission
network of headends, hub sites and HFC outside plants, and
transmitter sites. This unit manages the equipment that is co-
located on the site where the ROSA EM resides, whether this
equipment has an SNMP, serial (RS-232/422/485) or contact
closure interface.
The main functions of the ROSA EM are to:
Monitor the health of the transmission network
Act as an SNMP proxy
Send alarm notifications when a problem occurs
Automatically backup failed devices
Perform local automation tasks
The ROSA EM supports several hundred Scientific-Atlanta and third-party devices. Support for new devices is
continuously being added to the ROSA EM, which can be exported to existing installations with a simple software
upgrade.
The ROSA EM actively polls all of the devices that it manages looking for problems and in the event a problem is
detected, ROSA EM will send alarm notifications to the appropriate personnel via SNMP trap, Email, Pager or
SMS. ROSA EM communicates with the managed devices via their proprietary protocols or contact closures then
translates this information to SNMP, which can be passed to a higher level network management system. When
ROSA EM is configured to perform backup protection it will automatically initiate pre-defined backup schemes that
reroutes signals, activates and configures standby devices all within seconds of a device failure.
The ROSA EM is a 2 RU high, 19-inch rack-mount embedded platform that operates without a monitor or
keyboard. The operator interfaces with the ROSA EM via a simple easy-to-use and understand Web browser
client. Communication to the ROSA EM can be established over any LAN/WAN network that supports Ethernet.
In addition, dial-in and dial-out (e.g., ISDN) is supported for cases where only a switched connection is available.
Features
Cost-effective solution for management of devices in all locations (large headend to small hubs/OTN)
Manages Scientific-Atlanta and third-party equipment via proprietary protocol, SNMP, or contact closures
Translates proprietary protocols to SNMP and passes configuration/alarm information to network managers
Highly reliable (no fans, no hard drive) hardware and software solution
Alarm notification with Email, Pager or SMS
Easy to use, intuitive Web browser interface
Provides easy integration with multiple client options – Web browser, TNCS, ROSA NMS, 3
Open standards based interfaces (SNMP, HTTP, FTP, HMS, DateTime, etc.)
Delivered with software already installed
Software can be upgraded remotely over LAN/WAN
Automatic remote backup and restore to save the entire configuration of the ROSA EM
Seamless integration into currently installed TNCS and ROSA systems
Dual temperature probes available as option
2 RU, 19-inch rack-mount chassis
rd
Party NMS

Advertisement

loading

Summary of Contents for Scientific Atlanta Rosa

  • Page 1 The ROSA EM actively polls all of the devices that it manages looking for problems and in the event a problem is detected, ROSA EM will send alarm notifications to the appropriate personnel via SNMP trap, Email, Pager or SMS.
  • Page 2: Operation

    NMS client and third party Network Management Systems each designed to meet specific needs of the user. ROSA EM can be configured to do as much or as little as required to meet the needs of the technicians and engineers charged with managing the broadband network.
  • Page 3: Specifications

    Dielectric isolation Note: In case a client (simple Web browser, TNCS client, ROSA NMS client or third party NMS) is used in combination with ROSA EM, it must be possible to perform a successful ping command between ROSA EM and the client in both directions.
  • Page 4 ROSA EM - Element Management System Specifications - continued Remote Control and Configuration Ports - continued Analog Inputs Number of ports Connector type Contacts per port Input range Type Resolution Input impedance Analog Outputs Number of ports Connector type Contacts per port...
  • Page 5 ROSA EM - Element Management System Specifications - continued Management Specifications Number of managed devices depends on license with an absolute maximum of 1000 devices Maximum number of simultaneously connected web browser sessions is 12 Maximum number of simultaneously connected TNCS clients is 8...
  • Page 6: Ordering Information

    ROSA EM Hub & HFC ROSA EM Hub & HFC, 100 – 240 V AC EU DCL Class 6 (0-500 Hub & HFC network devices) ROSA EM Hub & HFC, 100 – 240 V AC UK DCL Class 6 (0-500 Hub & HFC network devices) ROSA EM Hub &...
  • Page 7 COPERNICUS ROSA Network Management Server 100-120/200-240 V AC Std Standard SQL database (MSDE) Including RS-232/4 and RS-485/4, ROSA 3.X Client, license for 250 points COPERNICUS ROSA Network Management Server 100-120/200-240 V AC LS Large System SQL database (MS SQL Server 2000 Standard Edition) Including RS-232/4 and RS-485/4, ROSA 3.X Client, license for 250 points...

This manual is also suitable for:

Rosa em