NOTE: Read the entire instruction manual before starting the
instruction.
TABLE OF CONTENTS
SAFETY CONSIDERATIONS
INTRODUCTION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INSTALLATION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Step 1—Check Existing Ductwork
Step 2—Insulate and Vapor- -proof Duct
Step 3—Install Coil in Supply Air Duct
Step 4—Connect Refrigerant Piping
Step 5—Connect Refrigerant, Liquid, & Suction Lines
REFRIGERANT METERING DEVICE
Step 1—Connect Condensate Lines
MAINTENANCE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Air Filter
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Condensate Pan and Drain
Cleaning Coil
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SAFETY CONSIDERATIONS
Improper installation, adjustment, alteration, service, maintenance,
or use can cause explosion, fire, electrical shock or other conditions
which may cause death, personal injury or property damage.
Consult a qualified installer, service agency, or your distributor or
branch for information or assistance. The qualified installer or
agency must use factory- -authorized kits or accessories when
modifying this product. Refer to the individual instructions
packaged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective clothing
and work gloves. Use quenching cloths for brazing operations.
Have fire extinguisher available. Read these instructions
thoroughly and follow all warnings or cautions attached to the unit.
Consult local building codes and the current editions of the
National Electrical Codes (NEC) NFPA 70.
In Canada, refer to the current editions of the Canadian Electrical
Code CSA C22.1.
Recognize safety information. This is the safety- -alert symbol
When you see this symbol on the unit and in instructions or
manuals, be alert to the potential for personal injury.
Installation Instructions
PAGE
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . .
. . .
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
Horizontal Duct Coils
Heating and Cooling
Understand the signal words DANGER, WARNING and
CAUTION. These words are used with the safety- -alert symbol.
DANGER identifies the most serious hazards which will result in
severe personal injury or death. WARNING signifies hazards
which could result in personal injury or death. CAUTION is used
to identify unsafe practices, which may result in minor personal
1
injury or product and property damage. NOTE is used to highlight
2
suggestions which will result in enhanced installation, reliability, or
operation.
2
2
!
2
ELECTRICAL SHOCK HAZARD
2
Failure to follow this warning could result in personal injury
2
or death.
2
Before installing, modifying or servicing system, always turn
3
off main power to system. There may be more than one
3
disconnect switch. Lock out and tag switch with a suitable
warning label.
3
4
!
4
4
CUT HAZARD
Failure to follow this caution may result in personal injury.
Sheet metal parts may have sharp edges or burrs. Use care and
wear appropriate protective clothing and gloves when
handling parts.
IMPORTANT: Nitrogen can leak out through the plug. This does
not indicate a leaking coil nor warrant return of coil.
.
WARNING
CAUTION

Advertisement

loading

Summary of Contents for Carrier CSPHP Series

  • Page 1 Horizontal Duct Coils CSPHP Heating and Cooling Installation Instructions NOTE: Read the entire instruction manual before starting the Understand the signal words DANGER, WARNING and CAUTION. These words are used with the safety- -alert symbol. instruction. DANGER identifies the most serious hazards which will result in TABLE OF CONTENTS severe personal injury or death.
  • Page 2 INTRODUCTION Step 2 — Insulate and Vapor- -proof Duct Externally insulated ductwork must have an adequate vapor seal Use these instructions to install Model CSPHP duct coils in for summer operation. This is particularly important where the duct horizontal position. (See Fig. 1.) It is easily adaptable to most types is exposed to high humidity conditions in attics, vented crawl of existing forced- -air heating systems, or can be installed in an spaces, unconditioned basements and utility rooms.
  • Page 3 CAUTION CAUTION UNIT OR PROPERTY DAMAGE HAZARD UNIT DAMAGE HAZARD Failure to follow this caution may result in property damage. Failure to follow this caution may result in property damage. Take precautions to ensure aluminum tubes do not come in DO NOT BURY MORE THAN 36 IN.
  • Page 4 NOTE: If unit is located in or above a living space, where damage WARNING may result from condensate overflow, a field- -supplied, external condensate pan should be installed underneath the entire unit, and a secondary condensate line (with appropriate trap) should be run ELECTRICAL SHOCK HAZARD from the unit into the pan.