Potterton Gold HE A Range Installation & Service Instructions Manual page 25

Gold he a range condensing combination boiler
Hide thumbs Also See for Gold HE A Range:
Table of Contents

Advertisement

16
14
12
10
8
6
4
2
0
0
2
3
4
5
6
7
1
Concentric 60/100 Flue (metres) Y
Example 1
Flue Lengths - Not Permissible
16
14
12
10
8
6
4
2
0
0
1
Example 3
Flue Lengths - OK
60Ø Exhaust
Y
Concentric 60/100 Flue
Fig. 26
Additional Accessories
A - 93° Elbow
5121369
B - 45° Elbow (Pair)
5121370
C - 1 metre 60Ø Extension
5121368
© Baxi Heating UK Ltd 2008
16
14
12
10
8
6
4
2
0
8
9
0
2
3
1
Concentric 60/100 Flue (metres) Y
Example 2
Flue Lengths - OK
2
3
4
5
6
7
Concentric 60/100 Flue (metres) Y
X
45° Elbow
93° Elbow
Concentric Flue
Fig. 27
9.0 Plume Displacement
9.2
In the graph the solid line diagonal represents the
relationship between the concentric flue assembly (and any
extensions) and the 60Ø exhaust (and any extensions or
additional bends).
Example 1 - Not Permissible
If, for instance, a concentric length of 5 metres was required
4
5
6
7
8
9
and the 60Ø exhaust needed to be 6 metres the graph
shows that this combination would NOT be permissible as
the intersection point would be above the solid diagonal line.
Example 2 - Flue Lengths OK
Where both lengths have been determined they can be
applied to the graph to check that the installation is
permissible. For example, if it was known that 2 metres of
concentric flue and 4 metres of 60Ø exhaust were required,
the values could be applied to the graph as shown in
Example 2.. As the point of intersection of the dotted lines is
below the solid diagonal line, the combination of lengths is
shown to be acceptable.
Example 3 - Flue Lengths OK
In the example shown in Fig. 4 assume that the concentric
part of the flue needs to be 2.3 metres long. Find the
position of '2.3' on the horizontal axis of the graph and then
project upwards to the solid diagonal line. This is represented
by the vertical thick dotted line. Where this dotted line
8
9
intersects with the solid diagonal line on the graph, project
across to the vertical axis. As can be seen this corresponds
with 6 metres. Therefore, the total equivalent length of the
60Ø exhaust can be up to 6 metres. Any bend equivalencies
must be accounted for i.e. 93° bends are equal to 1 metre,
each 45° bend to 0.5 metres.
Support
Bracket
Flue Length - Worked Example
Potterton Gold Combi 33HE
In Fig. 27 opposite an additional 93° bend and pair of 45°
elbows have been included in the 60Ø exhaust.
1 metre Extension
Also 3 straight extension pieces have been used.
To calculate total length:-
1 metre supplied in kit
Length of 60Ø supplied in kit =
3 x 1 metre Extensions =
1 x 93° Elbow =
2 x 45° Elbow =
Total 60Ø =
After consulting the table in Example 3 it can be determined
that the concentric flue could be up to approximately 2.3
metres long.
Determining Permissible Lengths
A
1 metre
3 metres
1 metre
1 metre (0.5 metres each)
6 metres
25