Slim Ducted Type Air Conditioner E S F DB98-27565A(1) USER’S MANUAL Indoor Unit EH035CAV EH052CAV EH070CAV (Cooling and Heating) Outdoor Unit UH035CAV UH052CAV UH070CAV...
N Please recycle or dispose of the packaging material for this product in an environmentally responsible manner. N Never store or ship the air conditioner upside down or sideways to avoid damage to the compressor. N The appliance is not intended for use by young children or infirm persons without supervision: Young children should be supervised to ensure that they do not play with the appliance.
View of the Unit The figures are shown in this instruction may differ from yours depending on the model. Indoor Unit outlet Indoor Unit ✴✴035✴✴ inlet ✴✴052/070✴✴ outlet inlet...
Page 5
✴✴035✴✴ Outdoor Unit Air Outlet ✴✴052✴✴ Outdoor Unit Air Outlet ✴✴070✴✴ Outdoor Unit Air Outlet Air Inlet(Rear) Connection Valve Air Inlet(Rear) Connection Valve Air Inlet(Rear) Connection Valve...
Off Timer setting Battery discharge indicator N After cleaning the air filter, press the N Duct type air conditioner does not have function of adjusting air flow direction. Therefore, the function is not operated even if you press the Mode selection button...
The Receiver & Display Unit The Receiver & Display unit is an optional accessory and it is installed on the wall. To use the receiver & display unit, refer to an appropriate manual. Concealed Type Standard Type Filter sign indicator Fan indicator Timer indicator Remote control sensor...
FILTER SIGN indicator when the time to clean the air filter; refer to page 13. N Duct type air conditioner does not have function of adjusting air flow direction. Therefore, the function is not operated even if you press the...
HEAT mode, the outdoor unit’s fan temperatures and compressor may stop at times. This is normal ; simply wait until the air conditioner switches on again. Power failure If a power failure occurs while the air conditioner is operating, the unit will be switched off.
64°F to 89°F If the outdoor temperature is as low as 0°C, the heating capacity drops up to 70~80% depending on the operating condition. If you use the air conditioner over 32°C(indoor temperature), the cooling capacity may drop. Then... The automatic protection feature may be triggered and the air conditioner stopped.
Cleaning Your Air Conditioner ✴✴ 052/070 ✴✴ For the best use of your air conditioner, you must clean it every 2 weeks regularly to remove the dust that accumulates on the air filter. Before cleaning your air conditioner, ensure that you have switched off the electric circuit breaker used for the unit.
Explanation/Solution N Check that the breaker used for the air conditioner is switched on. is displayed on the wired remote controller. In this case, turn the air conditioner off and contact your dealer.