Using the MV8-OP1 (Audio I/O Expansion) to connect external devices

Connecting a VM-7000/C7000 series device

R-BUS
MV-8000
Required equipment
• MV-8000 (with MV8-OP1 [sold separately] installed)
• VM-7200/7100 (with VM-24E [sold separately] installed)
• VM-C7200/7100
• RBC-1 (1 meter R-BUS cable) or RBC-3 (3 meter R-BUS cable)
• VM-LINK cable

Settings for each device

1.
Transferring audio
Model
MV-8000
VS-2480CD/
VS-2400CD
RPC-1
VM-7000
series
2.
Remote control using MMC
Model
MV-8000
VS-2480CD/
VS-2400CD
RPC-1
VM-7000
series
VM-7200/7100
+VM-24E
VM-LINK
Master (output device)
MIXER (INSTRUMENT PART) screen (p. 379)
• Output parameter of the part you want to send
to R-BUS: MLT1~8, M1/2~M7/8
GLOBAL screen (p. 320)
• R-BUS Word Clock parameter: Internal
PROJECT PARAMETER screen
• MASTER CLOCK parameter: INT
OUTPUT ASSIGN screen
• Connect the bus you want to output via R-BUS
to R-BUS (1/2~7/8)
• MASTER CLOCK parameter: Int. Clock
SYS DIGITAL screen
• WORD CLOCK SOURCE parameter:
INTERNAL
EZ ROUTING - MULTI IN screen
• In the patch bay, connect the signal from R-BUS
to the multi in mixer.
Master (controlling device)
SYNC screen (p. 259)
• MMC Mode parameter: Master
• MMC R-BUS parameter: On
MIDI PARAMETER screen
• MMC MODE parameter: Master
• In your sequencer software, set the MMC
parameter to Master.
• In your sequencer software, specify the RPC-1 as
the device that will transmit MMC.
SYS SYNC/MMC screen
• MMC CONTROL parameter: ON
• MMC MASTER parameter: INT
SYS MIDI screen
• Tx PARAM parameter: ON
VM-C7200/C7100
Slave
GLOBAL screen (p. 320)
• Input Select parameter: R-BUS
PROJECT PARAMETER screen
• MASTER CLOCK parameter: R-BUS
PATCH BAY screen
• Connect R-BUS 1 or 2 to the INPUT MIXER.
You must first load a 44.1 kHz project or create a
new one.
• MASTER CLOCK parameter: Ext. Clock
SYS DIGITAL screen
• WORD CLOCK SOURCE parameter: MULTI 1-8
/ MULTI 9-16 / MULTI 17-24
EZ ROUTING - MULTI IN screen
• In the patch bay, connect the signal from R-BUS
to the multi in mixer.
Slave (controlled device)
SYNC screen (p. 259)
• MMC Mode parameter: Slave (R-BUS)
MIDI PARAMETER screen
• MMC MODE parameter: SLAVE
• MMC SOURCE: R-BUS
• In your sequencer software, set the MMC
parameter to Slave.
• In your sequencer software, specify the RPC-1 as
the device that will receive MMC.
SYS SYNC/MMC screen
• MMC CONTROL parameter: ON
• MMC MASTER parameter: MULTI 1-8 / MULTI
9-16 / MULTI 17-24
SYS MIDI screen
• Rx PARAM parameter: ON