3—VS-2480CD Control Surface Settings
4. Select the control type you wish to set by cursoring to it or clicking on it with your
5. Once the control type is highlighted, turn the TIME/VALUE dial to select:
6. Highlight the corresponding Val setting to set the desired value for the selected
7. To switch from buttons, to knobs to faders, press the desired F button.
8. To finish setting up a USR template, press F6 (EXIT).
18
www.RolandUS.com
mouse.
•
OFF —so that no MIDI data is transmitted from the corresponding button, knob
or fader.
•
NOTE OFF —to transmit a MIDI note-off message.
•
NOTE ON —to transmit a MIDI note-off message
•
KEY PRESSURE —to transmit a MIDI aftertouch value.
•
CONTROL CHANGE —to transmit a value for one of the numbered MIDI
Control Change messages.
•
PITCH BEND —to transmit a MIDI pitch bend value.
control type.
If your control type is:
NOTE OFF
NOTE ON
KEY PRESSURE
CONTROL CHANGE
PITCH BEND
the Val setting determines:
the MIDI number of the note for which a note-off
message is sent
the MIDI number of the note for which a note-on
message is sent
the MIDI number of the note for which an
aftertouch message is sent
the MIDI control change message for which a value
is to be sent
the MIDI number of the note for which a pitch bend
message is sent
Roland VS-2480 Control Surface Mode Guide