Additional Clearances - Vent Terminal - Rinnai RL75I Operation And Installation Manual

Direct vent tankless water heater
Hide thumbs Also See for RL75I:
Table of Contents

Advertisement

Available languages

Available languages

Additional Clearances - Vent Terminal

Local codes supersede these clearances.
Avoid termination locations near a dryer vent.
Avoid termination locations near commercial cooking exhaust.
For VA3237 air intake position, follow the ANS Z21.10.3 ● CSA 4.3 requirements on the previous page.
Vent terminal (represents concentric vent terminal or VA3237 exhaust only vent terminal)
12"
(0.30 m ) to an
inside corner
(1.52 m) between
Rinnai terminals
at different levels
V
30
(0.91 m) to ventilated
or unventilated soffit
36"
or eve vent; or to a
deck or porch
V
V
12"
(0.30 m) between
Rinnai terminals at
same level
INSIDE
CORNER
60"
V
VB Series Indoor LS Manual
V
60"
(1.52 m) vertically
between Rinnai terminals
V
(0.61 m) to wall or parapet
24"
V
12"
(0.30 m) between
Rinnai terminals at
V
V
same level