Download Print this page

B&B Electronics Elinx EIR508 Series Quick Start Manual

B&b electronics elinx managed ethernet switch quick start guide

Advertisement

Quick Links

Quick Start Guide
Elinx Managed Ethernet Switch
EIR508 Series
1

Items Included

Ethernet Switch
o
CD with Support Manual
o
This Quick Start Guide
o
Panel Mount Bracket
o
2

Default Settings

IP Address: 192.168.16.1
o
Subnet Mask: 255.255.255.0
o
Gateway: 192.168.16.254
o
User Name: root, Password: root
o
3

DIP Switch Settings

Pos
Status Description
OFF
Disable port 1 Alarm
1
Enable port 1 Alarm
ON
(If port 1 link fails, the fault LED will light)
OFF
Disable port 2 Alarm
2
Enable port 2 Alarm
ON
(If port 2 link fails, the fault LED will light)
OFF
Disable port 3 Alarm
3
Enable port 3 Alarm
ON
(If port 3 link fails, the fault LED will light)
OFF
Disable port 4 Alarm
4
Enable port 4 Alarm
ON
(If port 4 link fails, the fault LED will light)
OFF
Disable port 5 Alarm
5
Enable port 5 Alarm
ON
(If port 5 link fails, the fault LED will light)
OFF
Disable port 6 Alarm
6
Enable port 6 Alarm
ON
(If port 6 link fails, the fault LED will light)
OFF
Disable port 7 Alarm
7
Enable port 7 Alarm.
ON
(If port 7 link fails, the fault LED will light)
OFF
Disable port 8 Alarm
8
Enable port 8 Alarm
ON
(If port 8 link fails, the fault LED will light)
OFF
Disable the ring master function.
9
Enable the switch as the ring master
ON
in the redundant ring group.
815-433-5100 Fax 433-5104
+353 91 792444 Fax +353 91 792445 www.bb-europe.com orders@bb-europe.com support@bb-europe.com
4
LED
Power
Power 1
Power 2
Fault
R.M.
LNK/ACT
Ports 7 & 8
FDX/COL
Ports 7 & 8
10/100 Ports
5

Hardware Installation

Record the switch's MAC Address in the space
o
provided. The MAC Address is printed on the product
label. Provide the MAC Address to your Network
Administrator. The Network Administrator should
provide an IP Address, Subnet Mask, and Gateway.
Select a mounting location and install with the attached
o
DIN rail clip or included panel mount kit.
Connect power to the switch
o
o
o
International Headquarters: 707 Dayton Road PO Box 1040 Ottawa, IL 61350 USA
www.bb-elec.com
European Headquarters: Westlink Commercial Park Oranmore Co. Galway Ireland
EIR508 Series-5107qsg
LED Chart
Status
Meaning
Green
The Switch is powered on
Off
The Switch is powered off
Green
Power Source 1 is available
Off
Power Source 1 is unavailable
Green
Power Source 1 is available
Off
Power Source 2 is unavailable
Yellow
Power Source failure or Port Failure
Off
Normal Operation
Green
Ring Master (Master of a redundant ring)
Off
The switch is not a Ring Master
Green
The port is linked
Blinking
The port is receiving or transmitting packets
Off
No device attached
Yellow
Full Duplex Mode
Blinking
Data Collision
Off
Half Duplex Mode
Green
Yellow
12 to 48 VDC
Redundant DC input is available with fault
contacts.
orders@bb-elec.com
support@bb-elec.com

Advertisement

loading

Summary of Contents for B&B Electronics Elinx EIR508 Series

  • Page 1: Dip Switch Settings

    Quick Start Guide Elinx Managed Ethernet Switch EIR508 Series Items Included Ethernet Switch CD with Support Manual This Quick Start Guide Panel Mount Bracket Default Settings IP Address: 192.168.16.1 Subnet Mask: 255.255.255.0 Gateway: 192.168.16.254 User Name: root, Password: root DIP Switch Settings...
  • Page 2: User Name And Password

    Log into the Switch Connect a stand alone PC to a port on the switch. Change the PC’s network IP Address to allow it to connect to the switch (ex: 192.168.16.2). Use the default subnet mask and gateway. Launch the PC’s web browser and navigate to the switch by typing the switch’s IP address in the browser...