Vulcan sps600v water filters: user guide (9 pages)
Summary of Contents for Vulcan-Hart MF50
Page 1
Vulcan Service Technician. Reproduction or other use of this Manual, without the express written consent of Vulcan-Hart, is prohibited. A product of VULCAN-HART LOUISVILLE, KY 40201-0696...
MOBILE FILTER - GENERAL GENERAL INTRODUCTION TOOLS • Mobile filters are used with fryers equipped with • Standard set of hand tools the Filter Ready option or Battery Inter-plumb • VOM with AC current tester (Any VOM with a Systems. sensitivity of at least 20,000 ohms per volt can be used.) •...
MOBILE FILTER - REMOVAL AND REPLACEMENT OF PARTS NOTE: The short screw is used on the right HEATER TUBE bracket behind the wheel. The long screws will interfere with the wheel. WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN SERVICING THE Remove the switch cover assembly from the FILTER.
MOBILE FILTER - SERVICE PROCEDURES AND ADJUSTMENTS Remove the pump from the from the pump MOTOR / PUMP base. WARNING: HOT OIL AND PARTS CAN CAUSE Disconnect the lead wires at the motor. BURNS. USE CARE WHEN SERVICING THE FILTER. WARNING: UNPLUG UNIT BEFORE SERVICING.
MOBILE FILTER - ELECTRICAL OPERATION Separate the castings one piece at a time, MOTOR RESET being careful not to damage the “O” rings between the castings. Turn the switch to the off position. NOTE: Only remove the first two castings. Press the reset button.
MOBILE FILTER - TROUBLESHOOTING TROUBLESHOOTING SYMPTOM CAUSES Motor will not run. Unit unplugged. Main circuit breaker open. Switch in incorrect position or a malfunction. Motor needs reset. Wiring problem. Motor malfunction. Will not pump, motor runs. Filter plugged. Heater tube plugged. Pump malfunction.