These power supplies are UL-Listed control units for use with electromagnetic locking devices and systems. They may be
ordered with optional battery backup systems to power devices in the case of power loss.
GENERAL DESCRIPTION:
POWER SUPPLY
POWER SUPPLY WITH
BATTERY BACKUP
DESCRIPTION
ENCLOSURE
DIMENSIONS
INPUT POWER
OUTPUT POWER
RATING
MAXIMUM # OF
MAGLOCKS
OUTPUTS
POWER SUPPLY BOARD DESCRIPTION:
TERMINAL
1
2
TB1
3
4 & 5
6 & 7
8 & 9
10 & 11
TB2
1 & 2
If after troubleshooting a problem, a satisfactory solution cannot be achieved, please call B.E.A., Inc.
1-800-523-2462 from 7am - 5pm or 1-800-407-4545 from 5pm - midnight & weekends.
DO NOT leave any problem unresolved. If you must wait for the following workday to call B.E.A., leave the door inoperable until
satisfactory repairs can be made. NEVER sacrifice the safe operation of the automatic door or gate for an incomplete solution.
12 and 24VDC POWER SUPPLY
12 VOLT
10PS12
10PS12PB
12 VDC RATED POWER SUPPLY
12" W x 14" L x 4"D
120 VAC
12 VDC
2 Amps
UP TO 3 MAGLOCKS
Fire alarm release
Auto/ Manual reset after fire alarm release
Auxiliary power for keypads/ external controls
N/C
Auxiliary form 'C' dry contact. Fire alarm supervised.
N/O
COMMON
Field selection for automatic or manual system reset. For system to automatically reset
when the fire alarm contact is reset, put jumper wire across these terminals. If manual
reset is required, a normally open (momentary switch) is used across these terminals.
Momentary activation of switch will reset the system.
To be tied to (normally closed) fire alarm contacts. The fire alarm contacts will open and
release all magnetic locks immediately. If fire alarm system supervision is not required,
a jumper across the terminals is required to derive 24 VDC from output terminals.
Auxiliary 12 VDC output (0.1 Amp max, not fused) for other system components,
requiring 12 VDC power.
(For 10PS24/PB only) Auxiliary 24 VDC output (0.25 Amp max, not fused) for other
system components, requiring 24 VDC power.
Optional battery backup unit terminals. Jump these two wires if battery backup is not
supplied.
for further assistance during Eastern Standard Time at
INSTRUCTION MANUAL
DESCRIPTION
24 VOLT
10PS24
10PS24PB
24 VDC RATED POWER SUPPLY
12" W x 14" L x 4"D
120 VAC
24 VDC
2 Amps
UP TO 6 MAGLOCKS
Fire alarm release
Auto/ Manual reset after fire alarm release
Auxiliary power for keypads/ external controls
75.0148 V1 July 2000

Advertisement

loading

This manual is also suitable for:

10ps24