BRUSH INSPECTION AND REPLACEMENT

Fig. 49
CAUTION: BEFORE INSPECTING BRUSHES, DISCONNECT THE MACHINE FROM THE POWER SOURCE.
Brush life varies, depends on the load on the motor. Check the brushes after the first 50 hours of use of a new
machine, or after a new set of brushes has been installed.
After the first check, examine them after about 10 hours of use, until replacement is necessary.
The brush holders (A) Fig. 49, are located on the motor housing opposite each other. Fig. 50, illustrates one of
the brushes removed for inspection. When the carbon on either brush (B) is worn to 3/16" in length, or if either
spring or shunt wire (C) is burned or damaged in any way, replace both brushes. If the brushes are found
serviceable after removing, reinstall them in the same position.
KEEP TOOL CLEAN
Periodically blow out all air passages with dry compressed air. Clean all plastic parts with a soft damp cloth.
NEVER use solvents to clean plastic parts. They could possibly dissolve or otherwise damage the material.
CAUTION: WEAR SAFETY GLASSES WHILE USING COMPRESSED AIR.

FAILURE TO START

Should your tool fail to start, check to make sure the prongs on the cord plug are making good contact with the
outlet. Also, check for blown fuses or open circuit breakers in the line.

SERVICE AND REPAIRS

All quality tools will eventually require servicing or replacement of parts due to wear from normal use. These
operations should ONLY be performed by either an AUTHORIZED PORTER-CABLE SERVICE STATION or a
PORTER-CABLE SERVICE CENTER. All repairs made by these agencies are fully guaranteed against defective
material and workmanship. We cannot guarantee repairs made or attempted by anyone other than these
agencies.
Should you have any questions about your tool, feel free to write us at any time. In any communication, please
give all information shown on the nameplate of your tool (model number, type, serial number, etc.).
PORTER-CABLE LIMITED ONE YEAR WARRANTY
Porter-Cable warrants its Professional Power Tools for a period of one year from the date of original purchase. We will repair or replace, at our option,
any part or parts of the product and accessories covered under this warranty which, after examination, proves to be defective in workmanship or material
during the warranty period. For repair or replacement, return the complete tool or accessory, transportation prepaid, to your nearest Porter-Cable Service
Center or Authorized Service Station. Proof of purchase may be required. This warranty does not apply to repair or replacement required due to misuse,
abuse, normal wear and tear or repairs attempted or made by other than our Service Centers or Authorized Service Stations.
ANY IMPLIED WARRANTY, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WILL
LAST ONLY FOR ONE (1) YEAR FROM THE DATE OF PURCHASE.
To obtain information on warranty performance please write to: PORTER-CABLE CORPORATION, 4825 Highway 45 North, P.O. Box 2468, Jackson,
Tennessee 38302-2468; Attention: Product Service. THE FOREGOING OBLIGATION IS PORTER-CABLE'S SOLE LIABILITY UNDER THIS OR ANY
IMPLIED WARRANTY AND UNDER NO CIRCUMSTANCES SHALL PORTER-CABLE BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL
DAMAGES. Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential
damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights and you may also have other legal rights which vary from state to state.
A
19
19
C
B
Fig. 50

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3802-ca

Table of Contents