Download Print this page

Philips iColor Accent Powercore Installation Instructions

Philips fixtures installation instructions

Advertisement

Quick Links

iColor accent powercore
i n s t a l l a t i o n
i n s t r u c t i o n s
Philips Color Kinetics
3 Burlington Woods Drive
Burlington, Massachusetts 01803 USA
Tel 888.Full.RGB
Tel 617.423.9999
Fax 617.423.9998
www.colorkinetics.com
item #
123-000017-00 (2-foot)
123-000017-01 (4-foot)
123-000017-02 (8-foot)
Copyright © 2009 – 2010 Philips Solid-State Lighting Solutions, Inc. All rights reserved.
Chromacore, Chromasic, CK, the CK logo, Color Kinetics, the Color Kinetics logo,
ColorBlast, ColorBlaze, ColorBurst, ColorGraze, ColorPlay, ColorReach, iW Reach,
eW Reach, DIMand, EssentialWhite, eW, iColor, iColor Cove, IntelliWhite, iW, iPlayer,
Optibin, and Powercore are either registered trademarks or trademarks of Philips
Solid-State Lighting Solutions, Inc. in the United States and / or other countries. All
other brand or product names are trademarks or registered trademarks of their
respective owners. Due to continuous improvements and innovations, specifications
may change without notice.
PUB-000166-00 Rev 06
Specifications subject to change without notice. Refer to www.colorkinetics.com for
the most recent version.
GettinG Started
The Philips iColor
®
Accent Powercore fixture is a direct view indoor /
outdoor linear fixture that can be used to create long ribbons of color to
highlight the outside of buildings or to create low-resolution video displays
in entertainment or retail applications. This guide contains important
information about installing and operating your new iColor Accent
Powercore fixtures safely and accurately.
included in this Box
• 1 iColor Accent Powercore fixture (either 2-ft (0.46 m),
4-ft (1.22 m), or 8-ft (2.44 m))
• User Guide
additional items needed
• Philips Data Enabler EO (Item #: 106-000003-06)
• 50 ft (15.24 m) Leader Cable (Item # 108-000028-01)
• 1 ft (.30 m) Jumper Cable (Item # 108-000029-03)
• 2 ft (.60 m) Jumper Cable (Item # 108-000029-06)
• 5 ft (1.52 m) Jumper Cable (Item # 108-000029-05)
• 10 ft (3.05 m) Jumper Cable (Item # 108-000029-04
• #10 mounting screws (M5) and tools
Scope of this document
The scope of this document is to explain in the steps necessary to install
iColor Accent Powercore and assure peak performance. Its intended use is for
reference only, by persons who are fully qualified. This document should never
be considered a substitute for any provision of a regulation or state and / or
local code.
identification and Warnings of Safety Hazards
In accordance with ANSI Z535.4-2002 the following system of identifying
the severity of the hazards associated with the products is used:
"
"
Imminently hazardous situation which, if not avoided, will
danger
result in death or serious injury.
"
" Potentially hazardous situation which, if not avoided, could
warning
result in death or serious injury.
"
"
Potentially hazardous situation which, if not avoided, may
caution
result in minor or moderate injury or property damage. Also used to alert
against unsafe practices.
.
ignoring a hazard will void any warranty
: Ensure that main power supply is off before installing, wiring, or
danger
servicing the iColor Accent Powercore.
: iColor Accent Powercore must be installed by a qualified
danger
electrician in accordance with NEC and relevant local codes.
: Do not attempt to install or use iColor Accent Powercore until
warning
you read and understand the installation instructions and safety labels.
: Do not use iColor Accent Powercore if the power cables are
warning
damaged.
: As dictated by a Structural Engineer and/or local code, install
warning
safety cables to iColor Accent Powercore fixtures.
: When using safety cables, ensure that they comply to the
warning
specifications given in this user guide.
: Do not attempt to remove the rubber purge ports located on
caution
the end caps of the fixtures.
: iColor Accent Powercore has no serviceable parts. Do not
caution
attempt to open the fixture.
: Do not use sharp tools near or on the fixture lens.
caution
: Do not hot swap. Ensure that power to the fixture is off before
caution
connecting or disconnecting fixtures.
: The instructions and precautions set forth in this user guide are not
note
necessarily all-inclusive, all conceivable, or relevant to all applications as
Color Kinetics cannot anticipate all conceivable or unique situations.
Owner / User responsibilities
It is the responsibility of the contractor, installer, purchaser, owner, and user
to install, maintain, and operate iColor Accent Powercore in such a manner
as to comply with all state and local laws, ordinances, regulations, and the
American National Standard Institute Safety Code.
planninG tHe inStallatiOn
The iColor Accent Powercore installation requires in-depth planning to
ensure timely, successful installation.
planning Suggestions
When planning iColor Accent Powercore installation, Philips Color Kinetics
suggests doing the following:
• Consult a Structural Engineer to design an installation scheme that is safe
and viable, and an Electrical Inspector to approve all wiring plans.
• Refer to local and state codes for installation compliance.
• Create a Layout Plan drawing.
• Create a Mapping Grid. Use this grid to record serial numbers for easy
reference and addressing.
• Consult Philips Color Kinetics Application Engineering Services as needed,
at support@colorkinetics.com.
installation Considerations
When creating your installation plan, consider the following:
• Location of Data Enabler EO in relation to the lights. Each Data Enabler
EO supports one leader cable.
• Location of the screw holes on the fixture and method of attaching. The
fixture can be installed using screws suitable for the mounting surface.
• Calculate the number of fixtures per Data Enabler EO. Use the
Configuration Calculator located at www.colorkinetics.com/support
to calculate the number of fixtures you can put on a Data Enabler EO.
This fixtures to Data Enabler EO ratio is determined by the parameters
of your installation. Installation parameters include all or some of the
following: line voltage, fixture type, leader length, and jumper lengths. In
any case, the run of iColor Accent Powercore fixtures cannot exceed 15
fixtures or 100 feet (30.48 m), not including the leader cable.
• Install and wire the Data Enabler EO before installing iColor Accent
Powercore fixtures. Refer to the Data Enabler EO User Guide.
StepS tO a SUCCeSSFUl inStallatiOn
There are two sets of installation steps, depending on whether your iColor
Accent Powercore fixtures will be controlled using Ethernet or DMX.
installation Steps for ethernet Control
1. Install the Data Enabler EO.
2. Install the fixtures.
3. Connect the fixtures to Light System Manager (LSM) or Video System
Manager (VSM).
Each of these steps are described below.
installing the data enabler eO (for ethernet)
Determine the location for the Data Enabler EO. One Data Enabler EO
can support a one leader cable. the run of iColor Accent Powercore
fixtures cannot exceed 15 fixtures or 100 feet (30.48 m), not including the
leader cable.
Things to remember:
• Install the Data Enabler EO according to state and local codes.
• Consult an Electrical Inspector to approve all wiring plans.
Refer to the Data Enabler EO User Guide for complete installation and
wiring instructions. After running power and data to the Data Enabler EO,
you are ready to attach the iColor Accent Powercore fixtures.
installing the Fixtures (for ethernet)
: Ensure that the power source is off before wiring the Data
danger
Enabler EO or connecting fixtures. Failure to do so will result in death and
will void the warranty.
iColor Accent Powercore fixtures are installed in series. The in-line
connectors allow the fixtures to butt up against one another, providing for
the best visual effects. Jumper cables are available to add space between the
fixtures when needed. Ensure correct expansion distance between fixtures
(see Table 1).
Mount the fixtures by using the mounting holes on each side of the fixture.
The number of mounting holes depends on the size of the fixture (see
Table 1).
table 1: iColor accent powercore Fixture dimensions
Fixture
Fastening
Size
a
B
C
d
locations
inches
inches
inches
inches
inches
per Fixture
cm
cm
cm
cm
cm
24
0.25
4.88
14.63
18.38
6
60.96
0.64
12.40
37.16
46.69
48
0.38
8.06
16.13
42.38
10
121.92
0.97
20.47
40.97
107.65
96
0.50
12.06
24.13
90.38
14
242.84
1.27
30.63
61.29
229.57
Use hardware suitable for the mounting surface. (See Figure 1.)
Table 1 lists the dimensions for the different size fixtures.
Figure 1
TOP VIEW
0.25 in (0.64 cm) THRU
(CLEARANCE FOR
#10 FASTENER)
B (SEE TABLE)
D (SEE TABLE)
: The iColor Accent Powercore fixture can be used as a template
note
when pre-drilled pilot holes are required. Hold the fixture in place and
mark the screw holes.
1. Position the first fixture in a series and attach it with the appropriate
number of #10 mounting screws suitable for the mounting surface.
Ensure that the male connector is in position to receive data and power
from the Leader Cable. (See Figure 2.) Table 1 lists the dimensions for
the different size fixtures.
2. Position the next fixture in the series, matching the male connector end
to the female connector of the previously mounted fixture. Attach the
fixture to the surface. (See Figure 2.) Table 1 lists the dimensions for the
different size fixtures.
The flexible connector cables allow for up to 180º turning radius.
Figure 2
SIDE VIEW
Leader
Cable
Female - to - Male
First Light in Series
Second Light in Series
Connection
TOP VIEW
0.25 in (0.64 cm) THRU
(CLEARANCE FOR
C (SEE TABLE)
B (SEE TABLE)
#10 FASTENER)
D (SEE TABLE)
A (SEE TABLE)
Mounting Base Plate Alignment
3. Continue mounting the fixtures, making power/data connections as you
go, until all lights in the series are mounted.
4. Once all fixtures are mounted and connected, connect the leader cable
from the Data Enabler to the first fixture in the series. Ensure power is
off when making this connection.
Weight
lbs.
kg
4.5
2.0
9.3
4.2
18.0
8.6

Advertisement

loading

Summary of Contents for Philips iColor Accent Powercore

  • Page 1 Accent Powercore and assure peak performance. Its intended use is for reference only, by persons who are fully qualified. This document should never be considered a substitute for any provision of a regulation or state and / or local code.
  • Page 2 For protection from extreme temperatures, the iColor Accent Powercore has been designed with a temperature monitoring feature. If operating temperatures rise to an unsafe level, a compensation circuit is triggered and the iColor Accent Powercore operation is interrupted causing the lights to turn dull red.