Prestige APS 685 Installation Instructions Manual page 10

4 channel remote start / keyless entry system
Table of Contents

Advertisement

3 Wire Positive Switched 2 Step Door Locks
The green wire provides a positive pulse during locking, or the pulsed + 12 volt lock output. Connect
the green wire to the wire that provides a low current positive signal from the factory door lock switch to
the factory door lock control relay.
The red wire provides a positive pulse during unlocking, or the drivers door pulsed positive unlock
output. Connect this wire to the drivers door unlock relay that requires a low current positive signal to
unlock only the drivers door. If the vehicle does not have a separate drivers door relay, one will have to be
added. Locate the drivers door unlock motor wire and cut it at a convenient location to allow wiring of an
optional relay. Connect the door side of the cut wire to terminal 30 of the optional relay added. Connect
the vehicle side of the cut wire to terminal 87a of the optional relay added. Connect the red wire of the 3
pin harness to terminal 86 of the optional relay added. Connect terminal 85 of the optional relay added to
chassis ground. Most vehicles door lock/unlock motor legs rest at ground, and switch +12 volts to the
door lock/unlock motor legs for operation, if this is the case in the vehicle you are working on, connect the
remaining terminal, 87, to a fused + 12 volt source. In the rare instance that the vehicle door lock/unlock
motor legs rest at + 12 volts and switches ground to the door lock/unlock motors, connect he remaining
terminal, 87, to chassis ground.
The Red/Black wire provides a pulse ground output when the unlock button of the transmitter is pressed
a second time after unlocking. Because the vehicle you are working on requires a positive pulse from the
factory door lock switch to the factory door lock control relay, you will have to add a relay to invert the
output polarity of this wire. Connect the Red/Black wire to terminal 86 of the optional added relay.
Connect terminal 85 & 87 to a fuse + 12 volt source. Connect terminal 30 to the low current door unlock
wire from the factory door switch to the door unlock control relay.