General Installation
Frame Ground Connection
IMPORTANT
Connect the system frame to the ground.
1.
Loosen the screw.
2.
Insert the grounding wire.
3.
Tighten the screw.
4.
Connect the grounding wire to the ground.
In most of the continental United States, the ground provided by the "Third wire ground" at the
commercial power outlet will be satisfactory. However, in a small percentage of cases this
ground may be installed incorrectly. Therefore, the following test procedure should be
performed.
Test Procedure
1.
Obtain a suitable voltmeter and set it for a possible reading of up to 250 VAC.
2.
Connect the meter probes between the two main AC voltage points on the wall outlet. The
reading should be 108 – 132 VAC.
3.
Move one of the meter probes to the 3rd prong terminal (GND).
Either the same reading or a reading of 0 V should be obtained.
4.
If a reading of 0 V at one terminal and a reading of 108 – 132 VAC at the other terminal is
not obtained, the outlet is not properly grounded. This should be corrected by a qualified
electrician (per article 250 of the National Electrical Code).
5.
If a reading of 0 V at one terminal and a reading of 108 – 132 VAC at the other terminal is
obtained, then set the meter to the "OHMS / RX1" scale, place one probe at the GND
Terminal and the other probe at the terminal which gave a reading of 0 V. A reading of less
than 1 ohm should be obtained. If the reading is not obtained, the outlet is not adequately
grounded. See a qualified electrician.