Omron M7 Instruction Manual

Omron M7 Instruction Manual

Digital automatic blood pressure monitor
Hide thumbs Also See for M7:

Advertisement

Introduction
The OMRON M7 measures your blood pressure and pulse simply and quickly from the arm, without the use of
an inflation bulb or stethoscope. The measurement values are stored in the memory of the OMRON M7.
The OMRON M7 includes the standard cuff for arm circumferences ranging from 22 to 42 cm.

Table of contents

2
3
4
4
4
5
6
6
7
M7
English
7
9
10
10
11
12
13
14
14
15
1

Advertisement

Table of Contents
loading

Summary of Contents for Omron M7

  • Page 1: Table Of Contents

    Introduction The OMRON M7 measures your blood pressure and pulse simply and quickly from the arm, without the use of an inflation bulb or stethoscope. The measurement values are stored in the memory of the OMRON M7. The OMRON M7 includes the standard cuff for arm circumferences ranging from 22 to 42 cm.
  • Page 2 Digital Automatic Blood Pressure Monitor Instruction manual page...
  • Page 3: How To Obtain Meaningful Blood Pressure Readings

    • You should never change the dose of medicines prescribed by your doctor. • Store the OMRON M7 in a dry, closed place with a temperature between -20°C and 60°C. • Remove the batteries if you do not intend to use the OMRON M7 for 3 months or more.
  • Page 4: Overview

    2 Overview A Display blood pressure B Display pulse, date and time C Memory buttons ( / ) D Date/time setting button E Start button F On/off button G Cuff H Air tube English J Air plug K Air jack L Battery compartment...
  • Page 5: Preparation

    3 Preparation 3.1 Insert batteries 1 Slide off the battery cover. 3.2 Control functions 2 Insert four batteries as indicated in the battery compartment and close compartment. Caution! Use four identical 1.5V batteries type AA! A Display blood pressure B Display pulse, date and time C Memory buttons ( / ) D Date/time setting button E Start button...
  • Page 6: Set Date And Time

    3.3 Set date and time At the first time you set the OMRON M7 the factory settings (12.00 - 1/1 - 2003) will be displayed. Another time the actual date and time will be displayed. Note: use the grey-coloured button to carry out the instruction.
  • Page 7: Connect Cuff

    3.4 Connect cuff P Air jack 3.5 Fit cuff 1 Bare your arm. Caution! Push up your sleeve: avoid constricting the blood flow! Caution! Do not inflate the cuff when not wrapped around the arm! 1 Insert air plug in air jack. 2 Open the cuff with right hand and cover the cuff over your left upper arm.
  • Page 8: Operation

    Note: keep marked edging on the inside of your elbow joint. Note: keep the tube even with your middle finger. 3 Hold the cuff, wrap it around your arm. Caution! Be sure the cuff fits closely; do not pinch your arm! 4 Operation 4.1 Measurement Note: for right arm use, keep the tube under your...
  • Page 9 Caution! Allow an interval of at least three minutes between two successive measurements! 1 Sit comfortably at a table with your feet flat on the floor and rest your arm on the table. mmHg mmHg PULSE /min 3 Press on/off button. Caution! Wait for zero and the heart symbol to continue! Caution! Do not remove cuff during inflation! mmHg...
  • Page 10: Read Display

    mmHg mmHg PULSE /min Note: Wait for automatic deflation. mmHg mmHg mmHg mmHg DATE/TIME PULSE PULSE START /min /min 5 If your systolic blood pressure is known to be more than 220 mmHg, press and hold the start button until the monitor inflates 30 or 40 mmHg higher than your estimated systolic blood pressure.
  • Page 11: Memory

    mmHg mmHg PULSE /min 3 Press on/off button to turn off power. Note: power automatically switches off after 5 minutes. 5 Memory 5.1 Recall previous values mmHg mmHg PULSE /min W Memory: stored measurements displayed. X Average: average value of the last 3 measurements displayed.
  • Page 12: Erase Memory

    mmHg mmHg mmHg mmHg DATE/TIME PULSE PULSE START /min /min 3 Press memory buttons ( / ) for latest and previous values. Press on/off button to turn off power. 5.2 Erase memory mmHg mmHg DATE/TIME PULSE /min 1 Press on/off button to turn on power. Caution! Wait for zero and the heart symbol to continue! mmHg mmHg...
  • Page 13: Storage

    • Remove the batteries if you do not intend to use the OMRON M7 for 3 months or more. • Store the OMRON M7 in the carton in a dry, closed place with a temperature between -20°C and 60°C. 2 Put cuff and main unit in storage case.
  • Page 14: Error: Causes And Rectifications

    7 Error: causes and rectifications Indication Error Incorrect inflation Correct measurement not possible Abnormal memory function Low voltage Display empty No data in memory Inexplicable values Cause Rectification Movement Repeat measurement. If necessary, hold start button to inflate manually Movement, sound Follow instructions, repeat Incorrect fastening cuff measurement...
  • Page 15: Maintenance And Spare Parts

    Manufacturer EU-representative This device fulfils the provisions of the EC directive 93/42/EEC (Medical Device Directive). This blood pressure monitor is designed according to the European standard EN1060, Non-invasive sphygmomanometers Part 1: General Requirements and Part 3: Supplementary requirements for electromechanical blood pressure measuring systems.
  • Page 16: General Information About Blood Pressure

    10 General information about blood pressure Blood circulation The blood circulation is responsible for supplying the body with oxygen. Blood pressure is the pressure exerted on the arteries. The systolic blood pressure value (higher pressure or top value) represents the blood pressure produced by contraction of the heart muscle.
  • Page 17 • Smoking • Excessive alcohol consumption • Stress and emotional upset • Excessive consumption of salt • Lack of physical exercise • Genetic/hereditary predisposition • Underlying illnesses, such as kidney disorders or endocrine disturbance Blood pressure measurement Measuring your blood pressure daily enables you to recognize high blood pressure at an early stage and obtain medical treatment.

Table of Contents