Atwood HYDRO FLAME 2H2C User Manual

Atwood mobile products thermostat user manual.
Hide thumbs
   
MPD 31493
LITERATURE NUMBER
hydro flame
TM
Model 2H2C
Two Stage Furnace
Digital Thermostat
9
FOR TWO STAGE FURNACE
ENGLISH, FRANCAIS
•Installation •Operation
(et Canada)
Effective 1/08
-
.
2
THIS THERMOSTAT HAS BEEN DESIGNED TO OPERATE STANDARD AIR CONDITIONING UNITS IN CONJUNCTION WITH AN EXCALIBUR
STAGE FURNACE
Screw Mounting Holes
THERMOSTAT INSTALLATION
Thermostat is very sensitive.
.
HANDLE WITH CARE AT ALL TIMES
Locate thermostat 48˝ to 54˝ above floor on an
wall.
INTERIOR
Mode
Pick a dry area where air circulation is good.
wall
Temperature
EXTERIOR
Set
Display
Set
location must have a 3/4˝ spacer between thermostat and
exterior wall.
1. Be sure all electrical power has been disconnected from
the air conditioner, furnace and the power supply.
2. Do not install the thermostat where there are unusual
M
(OFF)
OFF
HEAT
(CHAUFFAGE)
(CLIM) COOL
FAN (VENTIL.)
heating conditions: such as direct sunlight, heat produc-
ing appliances (television, radio, wall lamp, etc.)
or a furnace or air conditioner supply register.
System Switch
3.
. Separate the thermostat
ATTACHING THE WALL THERMOSTAT
body from the sub-base by gently squeezing the top and
* Note: Move jumper to
bottom. Pull wires through access hole in base plate.
positions 3 and 4 for RVP
1
2
3
4
5
6
7
8
Attach thermostat sub-base to the wall at the desired
12VDC
NOT
+12VDC
RELAY
A/C
A/C
A/C
TH FROM
Unit. Discard jumper for
Ground
USED
COM
COM-
HI
LOW
FURNACE
mounting location. Mount the sub-base to the wall before
Dometic
®
.
*
PRESSOR
FAN
FAN
connecting the wires.
System Slide Switch
SCROLL ORDER OF
OPERATION
LEFT
RIGHT
DISPLAYED MODES
Furnace Operation
Scroll Order of Displayed Modes
COOL
OFF
HEAT
FAN
AU
Furnace automatically switches between high and low BTU valve and high
and low speed fan when cycling to satisfy set point.
HI
Furnace high BTU valve and high speed furnace fan cycle to satisfy set point.
LO
Furnace low BTU valve and low speed furnace fan cycle to satisfy set point.
HF
Furnace fan runs at high speed to circulate air. Air conditioner fan does not run.
LF
Furnace fan runs at low speed to circulate air. Air conditioner fan does not run.
Air Conditioner Operation
COOL
OFF
HEAT
FAN
Scroll Order of Displayed Modes
Air conditioner automatically switches compressor and high and low speed fan when
AU
cycling to satisfy set point.
HI
Air conditioner compressor and high speed fan operate to satisfy set point.
LO
Air conditioner compressor and low speed fan operate to satisfy set point.
HF
Air conditioner fan runs at high speed to circulate air. Furnace fan does not run.
LF
Air conditioner fan runs at low speed to circulate air. Furnace fan does not run.
Fan Operation
Scroll Order of Displayed Modes
COOL
OFF
HEAT
FAN
HI
Air conditioner fan and furnace fan run at high speed to circulate air.
LO
Air conditioner fan and furnace fan run at low speed to circulate air.
Off
COOL
OFF
HEAT
FAN
Scroll Order of Displayed Modes
OF
No operation occurs.
Specifications
Operating Voltage
9VDC to 18VDC
Room Temperature Range
+55F to +90F
......................
..............
Power Consumption
100mA
Room Temperature Display Range
+35F to +99F
................................
..
Operating Temperature
-40F to +185F
Thermostat Accuracy
+/- 1F
..................
................................