Download Print this page

Mitsubishi PV-MJE265FB Installation Instructions

Photovoltaic module

Advertisement

Quick Links

PHOTOVOLTAIC MODULE

INSTALLATION INSTRUCTIONS

1.INTRODUCTION
• BEFORE INSTALLATION, OPERATION, AND MAINTENANCE, BE SURE TO READ THESE INSTRUCTIONS IN ORDER TO USE
THE PV MODULES SAFELY.
• FOR INSTALLATIONS IN THE USA, REFER TO THE NATIONAL ELECTRIC CODE (NEC) AND ALL APPLICABLE LOCAL CODES.
FOR INSTALLATIONS IN CANADA, REFER TO THE CANADIAN ELECTRIC CODE (CEC) AND ALL APPLICABLE LOCAL CODES.
• FAILURE TO OBSERVE THE FOLLOWING INSTRUCTIONS MAY RESULT IN DEATH OR PERSONAL INJURY AND PROPERTY DAMAGE.
• KEEP THIS MANUAL FOR FUTURE REFERENCE.
1. GENERAL USE
• Avoid touching the front surface of the module with bare
hands.
• DO NOT handle except for installation and maintenance.
• Ensure that unauthorised personnel, including children,
are not allowed to access the modules.
2. GENERAL HANDLING
• DO NOT alter or remove any component.
• DO NOT stand or step on the modules.
• DO NOT damage the front or rear surface of the PV
modules. The rear surface can be damaged by sharp
objects.
• DO NOT throw or drop the PV modules.
• DO NOT lift the modules by the connectors or cables.
3. INSTALLATION
• Only licensed professionals should handle the modules.
• Secure yourself to avoid falling from the installation area.
• DO NOT use damaged PV modules.
A damaged PV module may cause fire and/or an
electrical shock resulting in personal injury or even
death.
ELECTRICAL SPECIFICATIONS
MODEL
PV-MJE265FB
PV-MJE270FB
TOLERANCE
*1 FUSE RATING BASED ON MAX. BYPASS DIODE AMPACITY WITHIN THE PV MODULE
*2 MINIMUM BYPASS DIODE RATING
*3 +5/-0% OF NOMINAL VALUE
The electrical characteristics are within ±10% of the indicated values of Isc, Voc, and within +5/-0% of Pmax under
standard test conditions (irradiance of 1000 W/m
Standard: IEC61215 ed. 2 (2005), IEC61730 ed. 1 (2004) Application Class A, UL1703
SYMBOL DEFINITIONS
Pmax
MAXIMUM POWER
Voc
OPEN CIRCUIT VOLTAGE
Isc
SHORT CIRCUIT CURRENT
Vmp
MAXIMUM POWER VOLTAGE
Imp
MAXIMUM POWER CURRENT
Pmax
Voc
Isc
265 W
38.0 V
9.10 A
270 W
38.2 V
9.23 A
*3
-
-
2
WARNING
• DO NOT expose the PV modules to artificially
concentrated sunlight.
• Cover the front surfaces of the PV modules with an
opaque cloth to prevent the generation of high voltage
and electric current during installation.
• Securely fasten the PV modules to the mounting
framework to prevent them from falling due to wind or
snow loads. The modules should be installed as
instructed in this installation manual.
• Securely ground the PV module frame and the mounting
framework following local regulations.
• Install a residual current device (RCD) as prescribed by
local regulations.
• DO NOT expose the backside of the module to sunlight.
• DO NOT install the modules in places where they can be
shaded by objects such as buildings or trees.
Vmp
Imp
30.9 V
8.59 A
31.1 V
8.69 A
-
-
, AM1.5 spectrum, and a cell temperature of 25°C (77°F)).
En-1
CONFORMS TO STANDARD UL 1703
CERTIFIED TO ULC ORD C1703
*1 [A]
*2 [A]
MAXIMUM SYSTEM VOLTAGE
15
12.5
15
12.5
(IEC61215,IEC61730,UL1703)
-
-
ETL LISTED
1000V
-

Advertisement

loading

Summary of Contents for Mitsubishi PV-MJE265FB

  • Page 1: Installation Instructions

    A damaged PV module may cause fire and/or an electrical shock resulting in personal injury or even death. ELECTRICAL SPECIFICATIONS MODEL Pmax *1 [A] *2 [A] MAXIMUM SYSTEM VOLTAGE PV-MJE265FB 265 W 38.0 V 9.10 A 30.9 V 8.59 A 12.5 1000V PV-MJE270FB 270 W 38.2 V...
  • Page 2 1-1. STRUCTURE 6[0.24]×20[0.79](4 PLACES) C(4 PLACES) φ4.09[φ0.16](4 PLACES) 1657[65.2] A−A φ9[φ0.35](4 PLACES) Grounding Mark 24.5[0.96] D(4 PLACES) B−B Grounding Mark E(4 PLACES) 1000[39.4] Drainage holes 1199[47.2] 1200[47.2] 46[1.81] 6[0.24] φ4.09[φ0.16](4 PLACES) 1-2. MULTIPLYING FACTOR Under normal conditions, the PV module is likely to experience conditions that produce more current and/or voltage than reported under Standard Test Conditions.
  • Page 3 (20lbf-in). and nuts on the back of the module. • Ensure that at least 2 threads are engaged in the module Mitsubishi Electric Corp. frame. 5mm min. Frame (longer side) doesn't specify or •...
  • Page 4 • Use the appropriate tool provided by SMK for disconnecting. Printed in Japan All Rights Reserved. Copyright ©2015: MITSUBISHI ELECTRIC CORPORATION 1506876HC2701 En-4 * 8 7 6 H C 2 7 0 1 *...

This manual is also suitable for:

Pv-mje270fb