Zero clearance ventless firebox enclosure

Advertisement

Quick Links

INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
Conforms to the standard ANSI Z21.91 2004 Ventless Firebox Enclosures for Unvented Room Heaters
ZERO CLEARANCE VENTLESS FIREBOX ENCLOSURE
WARNING: If the information in these instructions is not followed exactly, a fi re or
explosion may result causing property damage, personal injury or death.
Do not store or use gasoline or other fl ammable vapours and liquids in the vicinity of
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your
building.
Installation and service must be performed by a qualifi ed installer, service
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada . (705) 721-1212 .
INSTALLATION INSTRUCTIONS FOR THE
MODEL ZCVF36
MODEL ZCVF42
CERTIFIED FOR UNITED STATES USING ANSI METHODS
FOR YOUR SAFETY
this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
• Immediately call your gas supplier
• If you cannot reach your gas supplier,
agency or the gas supplier.
fax(705)722-6031
from a neighbour's phone. Follow the
gas supplier's instructions.
call the fi re department.
1
W415-0527/ 09.29.05

Advertisement

loading

Summary of Contents for Napoleon ZCVF36

  • Page 1 Installation and service must be performed by a qualifi ed installer, service Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada . (705) 721-1212 . INSTALLATION INSTRUCTIONS FOR THE MODEL ZCVF36 MODEL ZCVF42 CERTIFIED FOR UNITED STATES USING ANSI METHODS FOR YOUR SAFETY this or any other appliance.
  • Page 2: Service History

    TABLE of CONTENTS PG 3 INTRODUCTION Warranty INSTALLATION & FINISHING General Instructions Hood Installation Gas Connector Locations Framing Nailing Tab Instruction Mantle Clearances OPTIONS Optional Blower Installation FOR USE ONLY WITH A ANSI Z21.11.2 LISTED GAS-FIRED UNVENTED ROOM HEATER NOT TO EXCEED 40,000 BTU/H FOLLOW THE INSTRUCTIONS, AND...
  • Page 3 NAPOLEON gas fi replaces are manufactured under the strict Standard of the world recognized NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fi red at a quality test station. The complete ventless fi rebox enclosure is test-fi...
  • Page 4 fi rebox enclosure to align with the three pre-drilled holes. 2. Screw the hood securely into place with the three screws provided. (FIGURE 1) W415-0527 / 09.29.05 SPECIFICATIONS ZCVF36 1 3/4” 42.000” 21 1/8” 31 7/8” 32 1/2”...
  • Page 5 There are fi ve gas inlet locations on the ventless fi rebox enclosure. One on each side of the unit, two at the rear, and one on the bottom. Using the following illustrations (FIGURE 2a-f) identify the preferred inlet and remove corresponding knock out. ZCVF36 7” 13 1/4”...
  • Page 6 ANY CHANGE TO THIS ENCLOSURE CAN BE DANGEROUS AND IS PROHIBITED. It is best to frame your ventless fi rebox enclosure after it is positioned. Use 2x4’s and frame to local building codes. ZCVF36 FIGURE 3 32 3/4" FIGURE 4 52 1/3”...
  • Page 7 NAILING TAB INSTRUCTION 1) Attach the nailing tabs to the corner posts using the 2 sheet metal screws supplied. Secure through the centre of the top and bottom slots in the nailing tab and then through the existing holes in the corner posts. If there are no existing holes, follow these instructions: Position the nailing tab so that the front face is offset with the front edge of the corner post (approx.
  • Page 8 OPTIONAL BLOWER INSTALLATION INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER and must be electrically connected and grounded in accordance with local codes. In the absence of local codes, use the current ANSI/NFPA 70 National Electrical Code. If the fi rebox was not previously equipped with a blower: route a grounded 2-wire, 60hz power cable through the junction plate cover.
  • Page 9 Note: In either application it is necessary to remove the variable speed switch from the wiring harness and install into an electrical switch box as per electrical codes. WITH THERMAL SWITCH BRACKET 1. Remove the hearth pads and the blower access cover. (FIGURE 9) 2.
  • Page 10 Normally all parts can be ordered through your Napoleon dealer or distributor. FOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM. ZCVF36 REPLACEMENT PARTS PART No. DESCRIPTION W385-0245...
  • Page 11 W415-0527/ 09.29.05...
  • Page 12 NOTES W415-0527 / 09.29.05...

This manual is also suitable for:

Zcvf42