Napoleon TORCH GT8N Installation And Operation Instructions Manual

Vented natural & propane gas fireplace

Advertisement

Quick Links

INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.22, ANSI Z21.50 FOR VENTED GAS FIREPLACE.
GT8N
NATURAL GAS
GT8P
Certified for Canadian and United States using ANSI/CSA Methods.
SAFETY INFORMATION
WARNING: If the information in these instructions
are not followed exactly, a fire or explosion may result
causing property damage, personal injury or loss of
life.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS:
● Do not try to light any appliance.
● Do not touch any electrical switch; do not use
any phone in your building.
● Immediately call your gas supplier from a
neighbour's phone. Follow the gas supplier's
instructions.
● If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by a
qualified installer, service agency or the supplier.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031
$10.00
PROPANE
www.napoleonfireplaces.com • ask@napoleon.on.ca
INSTALLATION

OPERATION INSTRUCTIONS

1
AND
W415-0619 / A / 08.09.07
W415-0619 / A / 08.09.07

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon TORCH GT8N

  • Page 1: Operation Instructions

    INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.22, ANSI Z21.50 FOR VENTED GAS FIREPLACE. GT8N NATURAL GAS GT8P PROPANE Certified for Canadian and United States using ANSI/CSA Methods. SAFETY INFORMATION WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result...
  • Page 2: Table Of Contents

    TABLE of CONTENTS PG 2-5 INTRODUCTION Warranty Dimensions General Instructions General Information Care of Glass & Plated Parts VENTING Venting Lengths Air Terminal Locations INSTALLATION/FRAMING Wall & Ceiling Protection Using Flexible Vent Components Horizontal Air Terminal Installation Fireplace Vent Connection Gas Installation Framing Nailing Tab Installation...
  • Page 3 NAPOLEON® products are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certifi cate. NAPOLEON® products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fi...
  • Page 4: General Instructions

    FIGURE 1 GENERAL INSTRUCTIONS THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes. Installation practices vary from region to region and it is important to know the specifi cs that apply to your area, for example: in Massachusetts State: •...
  • Page 5: Care Of Glass & Plated Parts

    CARE OF GLASS, AND PLATED PARTS USE CARE WHEN HANDLING GLASS COMPONENTS DO NOT STIKE, OR SLAM SHUT. The glass is 3/16” ceramic glass available from your Napoleon® / Wolf Steel Ltd. dealer. Clean the glass after the fi rst 10 hours of operation with a recommended gas fi...
  • Page 6 FIGURE 3 W415-0619 / A /08.09.07...
  • Page 7: Installation/Framing

    INSTALLATION / FRAMING WALL AND CEILING PROTECTION This application occurs when venting through an exterior wall. Having determined the air terminal location, cut and frame a hole in an exterior wall with a minimum square opening of 8” W x 8” H. IMPORTANT: For optimum performance, The vent pipe should rise ¼”...
  • Page 8: Fireplace Vent Connection

    FIREPLACE VENT CONNECTION 1. Install the 3” diameter vent pipe to the fi replace. Secure with 3 screws and fl at washers. Seal the joint and screw holes using Mill Pac sealant (W573-0007 not supplied). 2. Install the 5” diameter vent pipe to the fi replace. Attach and seal the joints.
  • Page 9: Electrical Connection

    NAILING TAB INSTALLATION To install the fi replace face fl ush with the fi nished surface, position the framework to accomodate the thickness of the fi nished surface. Use 4 self tapping screws to secure the nailing tabs to the 2 x 4’s. Cover the nailing tabs with your fi...
  • Page 10: Door Removal

    DOOR REMOVAL Before the glass door can be removed, the optional front must be removed. The glass door is secured to the top front edge of the fi rebox. Pull the handles of the latches forward, then lift the hooks out from the slots in the door frame to release the top of the door.
  • Page 11: Operating Instructions

    OPERATING INSTRUCTIONS When lit for the fi rst time, the fi replace will emit a slight odour for a few hours. This is a normal temporary condition caused by the curing of paints and lubricants used in the manufacturing process and will not occur again. Simply open a window to suffi...
  • Page 12: Maintenance

    TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE FIREPLACE. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. This fi replace and its venting system should be inspected before use and at least annually by a qualifi...
  • Page 13: Replacements

    Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your Napoleon® dealer or distributor. When ordering replacement parts always give the following information: FOR WARRANTY REPLACEMENT PARTS THE ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM REPLACEMENT PARTS PART NO.
  • Page 14: Trouble Shooting Guide

    TROUBLE SHOOTING GUIDE BEFORE ATTEMPTING TO TROUBLESHOOT PURGE YOUR UNIT AND INITIALLY LIGHT THE IGNITOR AND THE MAIN BURNER WITH THE GLASS DOOR OPEN SYMPTOM PROBLEM Electrode sparks, burner ignites, electrode Hot and neutral wires are reversed contiunes to spark for at control module.
  • Page 15 W415-0619 / A / 08.09.07...
  • Page 16 NOTES W415-0619 / A /08.09.07...

This manual is also suitable for:

Torch gt8p