Napoleon BGD36CFNTR Installation And Operating Instructions Manual

Napoleon BGD36CFNTR Installation And Operating Instructions Manual

Napoleon fireplaces gas fireplace installation and operating instructions
Table of Contents

Advertisement

CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS.
BGD36CFGN,
BGD36CFNTR & BGD42CFN
NATURAL GAS
BGD36CFGP,
BGD36CFPTR & BGD42CFP
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.
SAFETY INFORMATION
WARNING
!
If the information in these instructions are
not followed exactly, a fire or explosion may
result causing property damage, personal
injury or loss of life.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
- Do not try to light any appliance
- Do not touch any electrical switch; do
not use any phone in your building.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
- If you cannot reach your gas supplier,
call the fire department.
- Installation and service must be performed by a
qualified installer, service agency or the supplier.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 4Y8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030
(705)721-1212 • fax(705)722-6031 • www.napoleonfireplaces.com • ask@napoleon.on.ca
$10.00
INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE
OPERATING INSTRUCTIONS
PROPANE
INSTALLATION AND
1
W415-0661 / C / 02.20.08
W415-0661 / C / 02.20.08

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon BGD36CFNTR

  • Page 1 CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS. BGD36CFGN, BGD36CFNTR & BGD42CFN NATURAL GAS BGD36CFGP, BGD36CFPTR & BGD42CFP PROPANE CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS. SAFETY INFORMATION WARNING If the information in these instructions are...
  • Page 2: Table Of Contents

    INTRODUCTION Warranty General Instructions General Information Care of Glass & Plated Parts Unit Dimensions Installation Overview 6-19 VENTING Venting Lengths Minimum Air Terminal Location Clearances Typical Minimum and Maximum Vent Lengths Special Vent Installations Venting Application Flow Chart Venting Specifi cations BGD36CF(G) Pre-Installation Preparation Removing the Valve Access Door Door Operation...
  • Page 3 ® ® ® ® The following materials and workmanship in your new NAPOLEON® gas fireplace are warranted against defects for as long as you own the fireplace. This covers: combustion chamber, heat exchanger, stainless steel burner, phazer™ logs and embers, gold plated parts against tarnishing, porcelainized enameled components and aluminum extrusion trims.
  • Page 4: General Instructions

    GENERAL INSTRUCTIONS THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes. Installation practices vary from region to region and it is important to know the specifi cs that apply to your area, for example: in Massachusetts State: •...
  • Page 5: Unit Dimensions

    BGD36CF(G) FIGURE 1 " 34" FIGURE 3 27" 4" DIA. 7" DIA. 10" 40" INSTALLATION OVERVIEW See the section “MINIMUM MANTEL AND ENCLOSURE CLEARANCES” See the sections “MINI- MUM ENCLOSURE CLEARANCES” for drywall (or other combustible material) See the section “FRAMING”...
  • Page 6: Venting

    THE BGD36CF(G) USES: 4" EXHAUST / 7" AIR INTAKE VENT PIPE THE BGD42CF USES: 5" EXHAUST / 8" AIR INTAKE VENT PIPE MODEL BGD36CF MAY BE VENTED EITHER AS A TOP VENT OR A REAR VENT. REFER TO THE SECTION APPLICABLE TO YOUR INSTALLATION. For safe and proper operation of the fi...
  • Page 7 FIGURE 8 W415-0661 / C / 02.20.08...
  • Page 8: Typical Minimum And Maximum Vent Lengths

    TYPICAL MINIMUM AND MAXIMUM VENT LENGTHS BGD36CF(G) REAR EXIT For optimum performance, it is recommended that all horizontal runs FIGURE 9 have a 1" rise per foot. When terminating vertically, the vertical rise is a minimum 3 feet and a maximum 40 feet from the centre of the fi replace fl ue outlet. BGD42CF NOTE: When terminating vertically, the restrictor plate W500-0205 must be installed.
  • Page 9: Special Vent Installations

    SPECIAL VENT INSTALLATIONS BGD36CF(G) PERISCOPE TERMINATION Use the GD201 periscope kit to locate the air termination above grade. The periscope must be installed so that when fi nal grading is completed, the bottom air slot is located a minimum of 12" above grade.
  • Page 10: Venting Application Flow Chart

    VENTING APPLICATION FLOW CHART BGD36CF(G) REAR EXIT Horizontal Termination Vertical Vertical rise is rise is less than equal to or greater horizontal than the horizontal Horizontal Horizon- tal run + run + verti- vertical cal rise to maximum rise to maximum o f 2 4 .
  • Page 11 DEFINITIONS for the following symbols used in the venting calculations and examples are: > - greater than > - equal to or greater than < - less than < - equal to or less than - total of both horizontal vent lengths (H ) in feet - combined horizontal vent lengths in feet - offset factor: .03 (total degrees of offset - 90°*) in...
  • Page 12 BGD36CF(G) TOP EXIT / HORIZONTAL TERMINATION when (H ) > (V Simple venting confi guration (only one 90° elbow) See graph to determine the required vertical rise V for the required horizontal run H REQUIRED VERTICAL RISE IN INCHES V The shaded area within the lines represents acceptable values for H and V...
  • Page 13 BGD36CF(G) REAR EXIT / HORIZONTAL TERMINATION when (H ) < (V Simple venting confi guration (only two 90° elbows) FIGURE 25 See graph to determine the required vertical rise V horizontal run H REQUIRED VER- TICAL RISE IN FEET HORIZONTAL VENT RUN PLUS OFF- SETS IN FEET H The shaded area within the lines represents acceptable values for H...
  • Page 14 BGD36CF(G) TOP OR REAR EXIT VERTICAL TERMINATION when (H ) < (V Simple venting confi guration (only two 90° elbows) FIGURE 29 REQUIRED VERTICAL RISE IN FEET V HORIZONTAL VENT RUN PLUS OFFSET IN FEET H The shaded area within the lines represents acceptable values for H and V See graph to determine the required vertical rise V...
  • Page 15 BGD36CF(G) TOP OR REAR EXIT VERTICAL TERMINATION Example 8: 90° 45° 90° = 1.5 ft = 5 ft = 1.5 + 5 = 6.5 ft = 1 ft = 1 ft = 10.75 ft = .03 (three 90° elbows + one 45° elbow - 90°) = .03(90 + 90 + 90 + 45 - 90) = 6.75 ft 90°...
  • Page 16 BGD42CF HORIZONTAL TERMINATION when (H ) < (V Simple venting confi guration (only one 45º and 90° elbow) FIGURE 34 REQUIRED VERTICAL RISE IN FEET CALCULATED HORIZONTAL VENT RUN PLUS OFFSETS IN FEET (H The shaded area within the lines represents acceptable values for and V For vent confi...
  • Page 17 BGD42CF VERTICAL TERMINATION when (H ) < (V Simple venting confi gurations FIGURE 38 See graph to determine the required vertical rise V for the required horizontal run H MAXIMUM VERTICAL RISE IN FEET HORIZONTAL VENT RUN PLUS OFFSET IN FEET H The shaded area within the lines represents acceptable values for H...
  • Page 18 BGD42CF VERTICAL TERMINATION when (H ) > (V Simple venting confi gurations FIGURE 40 See graph to determine the required vertical rise V horizontal run H MAXIMUM VERTICAL R I S E I N FEET HORIZONTAL VENT RUN PLUS OFFSET IN FEET H The shaded area within the lines represents acceptable values for H...
  • Page 19: Bgd36Cf(G) Pre-Installation Preparation

    BGD36CF(G) PRE-INSTALLATION PREPARATION (THIS PROCEDURE IS NOT REQUIRED FOR THE BGD42CF) For optimum performance, it is recommended that all horizontal runs have a 1" rise per foot. REMOVING THE VALVE ACCESS DOOR 1. The valve access door rotates on the pins attached to the side frame.
  • Page 20: Adjustable Firestop Installation

    BGD42CF ONLY ADJUSTABLE FIRESTOP INSTALLATION Apply a bead of caulking all around the edge of the opening and place the fi restop top, so that the vent shield covers the top of the vent within the opening. The length of the vent shield may be cut shorter for combustible walls that are less than 8 1/2"...
  • Page 21: Using Flexible Vent Components

    USING FLEXIBLE VENT COMPONENTS THE BGD36CF(G) USES: 4" EXHAUST / 7" AIR INTAKE VENT PIPE WITH A MINIMUM 6" BEND RADIUS THE BGD42CF USES: 5" EXHAUST / 8" AIR INTAKE VENT PIPE WITH A MINIMUM 8" BEND RADIUS WARNING Do not allow the inside liner to bunch up on horizontal or vertical runs and elbows.
  • Page 22: Using Rigid Vent Components

    USING RIGID VENT COMPONENTS HORIZONTAL AIR TERMINAL INSTALLATION 1. Move the fi replace into position. Measure the vent length required between terminal and fi replace taking into account the additional length needed for the fi nished wall surface and any 1¼" overlaps between venting components.
  • Page 23: Restricting Vertical Vents (Bgd42Cf Only)

    RESTRICTING VERTICAL VENTS BGD42CF ONLY: Vertical terminations may display a very active fl ame. As this appearance is not desirable, the vent exit must be restricted using restrictor plate, W500-0205. This reduces the velocity of the exhaust gases, slowing down the fl ame pattern and creating a more traditional appearance.
  • Page 24: Framing

    BGD36CF(G) MINIMUM CLEARANCE TO COMBUSTIBLE CONSTRUCTION FROM FIREPLACE AND VENT SURFACES: Non-Combustible framing: Combustible framing: Sides, back, and bottom of the unit Non-combustible fi nishing: Combustible fi replace fi nishing: Sides, bottom and top Enclosure top Recessed depth Sides and bottom of the vent pipe Top of vent pipe Ceiling HORIZONTAL VENT SECTIONS: - A minimum clearance of 1"...
  • Page 25 BGD36CF(G) " " " FIGURE 70 OUTSIDE CHASE " Warning: Non-combustible Finishing Materials Required Non-combustible materials such as brick and tile can be extended over the black face of the unit. FIGURE 72 12” TO COMBUSTIBLE MANTLE IMPORTANT: Encroaching in this area with fi...
  • Page 26: Bgd36Cf(G) Minimum Mantel And Enclosure Clearances

    BGD36CF(G) MINIMUM MANTEL AND ENCLOSURE CLEARANCES Combustible mantel clearance can vary according to the mantel depth. Use the graph to help evaluate the clearance needed. FIGURE 77 The fi replace requires a minimum enclosure height of 38 1/2“ (REAR VENT) 49" (TOP VENT). For temperature requirements, the enclosure space around and above the fi...
  • Page 27: Clean Face Surround Minimum Enclosure Clearances

    CLEAN FACE SURROUND MINIMUM ENCLOSURE CLEARANCES OPTIONAL CLEAN FACE SURROUND INSTALLATION BGD36CF(G) ONLY FIGURE 83 WAVE S36WN (BROWN) S36WP (PEWTER) Installation requires a minimum of 6 1/2" non-combustible facing material at the top of the fi replace. Refer to either Figure 86a or Figure 86b (depending on your installation) to ensure your fi...
  • Page 28: Hearth Installation

    When installing to a hearth the fi replace riser must create a minimum clearance of 3 3/8" PLUS the height of the hearth from the fi nished fl oor to the bottom of the fi replace. STAND-OFF CLEAN FACE SURROUND KIT CLEANFACE SURROUND FINISHED FLOOR...
  • Page 29: Bgd42Cf Minimum Mantel And Enclosure Clearances

    BGD42CF MINIMUM MANTEL AND ENCLOSURE CLEARANCES Combustible mantel clearance can vary according to the mantel depth. Figure 92. Use the graph to help evaluate the clearance needed. These same requirements apply to any combustibles protruding on either side of the fi replace. FIGURE 92a The fi...
  • Page 30: Bgd36Cf Finishing

    FINISHING BGD36CF FINISHING LOG PLACEMENT PHAZER logs and glowing embers exclusive to Napoleon® Fire- places, provide a unique and realistic glowing effect that is different in every installation. Take the time to carefully position the glowing embers for a maximum glowing effect. Log colours may vary.
  • Page 31: Door Trim

    DOOR TRIM The BGD42CF comes complete with top door FACING trim (W715-0729). 1. Guide the arms of the DOOR trim into the slots that are slightly hidden under the facing through the open- ing between the top of the door and the bottom edge BGD42CF FRONT VIEW of the facing as illustrated NOTCH...
  • Page 32: Common Finishing

    COMMON FINISHING BGD36CF / BGD42CF GLOWING EMBERS Tear the embers into pieces and place along the front row of ports covering all of the burner area in front of the small logs (#2 & #3). Care should be taken to shred the embers into thin, small irregular pieces as only the exposed edges of the fi...
  • Page 33: Optional Blower Installation

    OPTIONAL BLOWER INSTALLATION BGD36CF(G) ACCESSING THE BLOWER 1. Remove the valve access door. 2. Open the main door. 3. Carefully remove the logs. 3a. (BGD36CFG) Carefully remove the glass and glass ember tray. 4. Remove the 7 screws illustrated in Fig. 112a and lift out the log support.
  • Page 34: Optional Fan Installation

    Attach the connectors from FIGURE 119 the black and white wires to the thermodisc and secure the thermodisc bracket to the secur- ing stud at the bottom left of the unit using a lock washer and wing nut. Ensure that the thermodisc touches the fi...
  • Page 35: Bgd36Cfg Burner Switch/Wiring Diagram

    BGD36CFG BURNER SWITCH / WIRING DIAGRAM A wall switch must be installed in a convenient location for the burn- er operation. The recommended maximum lead length depends on wire size: WIRE SIZE MAX. LENGTH 14 gauge 16 gauge 18 gauge FIGURE 125 IRE TAGS ARE BRACKETED...
  • Page 36: Bgd36Cfg Light Switch/Wiring Diagram

    BGD36CFG LIGHT SWITCH / WIRING DIAGRAM A wall switch must be installed in a convenient location for the light operation. The recommended maximum lead length depends on wire size: WIRE SIZE 14 gauge 16 gauge 18 gauge FIGURE 126 W415-0661 / C / 02.20.08 A 20’...
  • Page 37: Receptacle Wiring Diagram

    RECEPTACLE WIRING DIAGRAM FIGURE 127 W415-0661 / C / 02.20.08...
  • Page 38: Operation Bgd36Cf And Bgd42Cf

    OPERATION BGD36CF & BGD42CF Purge all gas lines with the glass door of the fi replace removed or opened. Assure that a continuous gas fl ow is at the burner before installing the door. When lit for the fi rst time, the fi replace will emit a slight odour for a few hours.
  • Page 39: Operating Instructions

    OPERATION BGD36CFG FOR YOUR SAFETY READ BEFORE OPERATING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. THIS FIREPLACE IS EQUIPPED WITH AN IGNITION DEVICE WHICH AUTOMATICALLY LIGHTS THE PILOT.
  • Page 40: Adjustments

    PILOT BURNER ADJUSTMENT EXCLUDING BGD36CFG Adjust the pilot screw to provide prop- erly sized fl ame. Turn in a clockwise direction to reduce the gas fl ow. FIGURE 128 FIGURE 129 VENTURI ADJUSTMENT Both fi replace models have air shutters that have been factory set open according to the chart below: BGD36CF BGD36CFG...
  • Page 41: Flame Adjustment

    Turn clockwise to increase fl ame height For BGD36CF and BGD42CF It is important to periodically perform a visual check of the pilot and the burner fl ames. Compare them to the fi gures shown. If any fl ames appear abnormal call a service person.
  • Page 42: Common Replacements

    COMMON REPLACEMENTS Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your Napoleon® dealer or distributor. When ordering replacement parts always give the following informa- tion: 1. M & S ODEL ERIAL UMBER OF FIREPLACE...
  • Page 43: Bgd42Cf Replacements

    BGD42CF REPLACEMENTS BGD42CF COMPONENTS: W455-0019 #43 NATURAL GAS ORIFICE W455-0003 #54 PROPANE GAS ORIFICE W010-0864 PAN BURNER GL-641 LOG SET W135-0198 BACK LOG (#1) W135-0201 LEFT CROSSOVER LOG (#4) W135-0203 RIGHT CROSSOVER LOG (#5) W135-0199 SMALL LEFT LOG (#2) W135-0200 SMALL RIGHT LOG (#3) W010-1819 BLACK DOOR C/W GLASS...
  • Page 44 W415-0661 / C / 02.20.08...
  • Page 45 BGD36CFG TROUBLE SHOOTING GUIDE EFORE ATTEMPTING TO TROUBLESHOOT PURGE YOUR UNIT AND INITIALLY LIGHT THE PILOT AND THE MAIN BURNER WITH THE GLASS DOOR REMOVED SYMPTOM PROBLEM Pilot will not light. - Wiring Makes noise with no - Loose connection spark at pilot burner - Module - Igniter Spark gap is...
  • Page 46 BGD36CFG TROUBLE SHOOTING GUIDE SYMPTOM PROBLEM - Wiring / Connection Pilot lights Stops sparking - Wiring harness / pilot remains lit but burner will not turn on - Module or Valve - Fireplace is spilling. Exhaust fumes smelled in room, headaches. Carbon is being deposited - Air shutter has become blocked on glass, logs or combus-...
  • Page 47 BGD36CF / BGD42CF TROUBLE SHOOTING GUIDE EFORE ATTEMPTING TO TROUBLESHOOT PURGE YOUR UNIT AND INITIALLY LIGHT THE PILOT AND THE MAIN BURNER WITH THE GLASS DOOR OPEN SYMPTOM PROBLEM Main burner goes out; Pilot fl ame is not large enough or pilot stays on.
  • Page 48 BGD36CF / BGD42CF TROUBLE SHOOTING GUIDE SYMPTOM PROBLEM Flames are consist- Unit is over-fi red or under-fi red. ently too large or too small. Carboning oc- curs. Door is ajar Flames are very ag- gressive. MODEL BGD42CF ONLY: Aggressive venting action due to vent height.