Summary of Contents for Lincoln Electric RANGER 405D
Page 1
Engine - Kubota / Perkins SAFETY DEPENDS ON YOU Lincoln Electric welders are designed and built with safety in mind. However, your overall safety can be increased by proper installation and thoughtful operation on your part. Read and observe the general safety precautions on page 2 and follow specific installation and operating instructions included in this manual.
This can create fire hazards or including the material safety data sheet (MSDS) and overheat lifting chains or cables until they fail. follow your employer’s safety practices. h. Also see Item 7c. e. Also see Item 7b. Page 2 Ranger 405D IMA 608D...
Page 3
3. Should the primary cord be damaged, a special cord is required, and is available from Lincoln Electric. 4. Parts should be ordered from Lincoln, its offices or the nearest Authorised Field Service Shop. (The “Lincoln Service Directory” listing these shops geographically is available on request.)
Only ‘ACROSS THE ARC’ type wire feeders with a internal contactor fitted should be used in this configuration. Arc air gouging is not recommended in CV. Due to ‘CV MODE’ not offering VRD protection. Page 4 Ranger 405D IMA 608D...
(This is also a good you and your pacemaker. practice to eliminate a common problem on welding - a poor work connection. • Do not work next to the welding power source. IMA 608D Ranger 405D Page 5...
• for using with other Lincoln Electric/LiquidArc equipment. as filtering the mains supply. Consideration should be given to • designed for industrial and professional use.
PRODUCT DESCRIPTION The Ranger 405D is a diesel engine driven alternator power source for multi-process DC welding and for 115/230-240/400-415VAC auxiliary* and standby power. It is housed in a sound reduced enclosure for quiet operation. Auxiliary outlets and circuit breakers depend on model purchased.
Fill the fuel tank with clean, fresh diesel fuel. The capacity is 45 litres. See engine Operator’s Manual for specific fuel recom- Battery Connection Instructions mendations. Do not allow the Ranger 405D to run out of fuel. This necessitates bleeding the injector system. The Ranger is shipped with the negative battery cable disconnected.
Use in open, well ventilated areas or vent exhaust outside. • Do not operate with doors open or guards off. • Stop engine before servicing. M OV I NG PA RTS can injure Keep away from moving parts. IMA 608D Ranger 405D Page 11...
A T12246 BYPASS CAPA C I TOR A S S E M B LY M U S T B E 25/35mm Cable: No trim I N S TALLED IN THE RANGER 405D TO PROTECT T H E 50mm Cable: Trim at “A”...
Allows machine maintenance procedures to be adhered to by machines being used in environments with high-risk of electric recording engine operating hours. shock. Fuel Gauge Provides indication of the amount of fuel in the fuel tank. IMA 608D Ranger 405D Page 13...
Check fuel gauge to pressure to build up. Therefore if a fault is still present the engine ascertain fuel level in fuel tank (never allow Ranger 405D to will stop again after approx 10 seconds.
TIG Welding The Ranger 405D can be used for a variety of DC tungsten inert gas (TIG) welding applications. Arc initiation may be by “scratch” starting, or by use the K930 Hi-Freq unit. Scratch starting is not...
All welder and engine controls are located on the case front panel. Refer to diagram and the explanations that follow. 1. Output Control Dial 5. VRD Operation Indicator On the front panel of the Ranger 405D are two indicator lights. A red light when lit indicates voltage >32V and a green light when Increase/Decrease of output “...
Page 17
Australian Standard AS3000. 10. Hour Meter The hour meter displays the total time that the engine has been running. This meter is a useful indicator for scheduling preventive maintenance. IMA 608D Ranger 405D Page 17...
Amphenol Receptacle machine, switch to “ ” position. For remote control, switch to “ The Ranger 405D has one 14pin amphenol located on the ” position, in this position control is at the wire feeder (if so control panel. The receptacle is for connecting wire feeders,...
Page 19
INSTALLATION INSTRUCTIONS IMA 608D Ranger 405D Page 19...
• Do not ground the Ranger 405D to a pipe that carries explosive or combustible material. When the Ranger 405D is mounted on a truck or trailer, its frame must be electrically bonded to the metal frame of the vehicle. Use a 10mm (#8) or larger copper wire connected between the machine grounding stud and the frame of the vehicle.
KA1453-6, 1 x 400V 3ø, 1 x 230V & 1 x 115V 1ø outlets CA U T I O N Caution: Certain electrical devices need some extra care so they can be powered by the Ranger 405D. Refer to Table for these devices. Type...
Consult your local KUBOTA/PERKINS Dealer for this service. Replace only if necessary. Every Year or every 6 times of cleaning ◊ Emission related critical part. Owner is responsible for proper maintenance Please see Engine Owners Manual for Warranty Statement in detail. Page 26 Ranger 405D IMA 608D...
It IS permissible to use oil that meets S and C grade service classifications.) Any engine will use a small amount of oil during its "run-in" period. For the diesel engine on the Ranger 405D, run-in is about 50 SAE 10W30 is recommended for general, all temperature use, - running hours.
2. Avoid Dislodging Dust from the Filter Gently pull the filter off the outlet tube and out of the housing. Avoid knocking the filter against the housing. Page 28 Ranger 405D IMA 608D...
COOLING SYSTEM FUEL At the end of each day’s use, refill the Ranger 405D fuel tank to W A R N I NG minimize moisture condensation and dirt contamination in the fuel line. Do not overfill; leave room for the fuel to expand.
Keep sparks, flame and cigarettes away MAINTENANCE from battery. To prevent Explosion when: STORAGE: Store the Ranger 405D in clean, dry protected areas. • Installing a new battery - disconnect negative cable from old battery first and connect to new battery last CLEANING: Blow out the generator and controls periodically with •...
320 grit sanding stone. Slip rings must be clean and other auxiliary circuit which operates at free from oil and grease. a voltage not exceeding extra low voltage Between separate welding circuits IMA 608D Ranger 405D Page 31...
Page 32
ENGINE SERVICE RECORD FOR RANGER 405D SERIAL 800 HOUR SERVICE 50 HOUR 1ST SERVICE Agent Name Agent Name Date Hourmeter Date Hourmeter Tick completed operations Tick completed operations • Change fuel filter element • Change of engine oil • Change of engine oil •...
Page 33
ENGINE SERVICE RECORD FOR RANGER 405D SERIAL 1600 HOUR SERVICE 2400 HOUR SERVICE Agent Name Agent Name Date Hourmeter Date Hourmeter Tick completed operations Tick completed operations • Check fuel injection nozzle pressure • Change of engine oil • Change fuel filter element •...
Page 34
INSULATION & RESISTANCE RECORD FOR RANGER 405D SERIAL Agent Name Agent Name Date Date INSULATION TESTING INSULATION TESTING Record Test Results Record Test Results • Earth continuity (< 1Ω) Ω • Earth continuity (< 1Ω) Ω • Auxiliary and Earth (>10MΩ) MΩ...
Page 35
INSULATION & RESISTANCE RECORD FOR RANGER 405D SERIAL Agent Name Agent Name Date Date INSULATION TESTING INSULATION TESTING Record Test Results Record Test Results • Earth continuity (< 1Ω) Ω • Earth continuity (< 1Ω) Ω • Auxiliary and Earth (>10MΩ) MΩ...
Page 36
Refer PCB Trouble Shooting page 18 V) Faulty rotor/weld control PCB Refer PCB Trouble Shooting page 18 VI) Faulty relay R1 and/or R2 Replace VII) Faulty idler solenoid Repair/replace V I I I ) Faulty throttle linkages Repair/replace Page 36 Ranger 405D IMA 608D...
II) Faulty rotor/weld control PCB Refer PCB Trouble Shooting page 18 III) Faulty choke/inductor Repair/replace IV) Faulty reactors (one per each weld phase) Repair/replace V) Faulty capacitors Replace all 4 capacitors at one time IMA 608D Ranger 405D Page 37...
The weld control circuitry has 2 modes of operation Constant Brief Operating Description Current (CC) and Constant Voltage (CV). The Ranger 405D has 5 separate PCBs. These are: In CC mode, feed back to the control circuitry is provided by a 400 Amp to 50mV shunt, thus maintaining the 1) Watcher/Idler PCB –...
Page 39
Operative: Sep 2004 Supersedes: Jul 2004 RANGER 405D Model Index DO NOT attempt to use this Parts List for machine if its code NUMBERS IN THE TABLE BELOW INDICATE WHICH number is not listed. Contact the Service Department for any COLUMN TO USE IN EACH PARTS LIST FOR EACH code numbers not listed.
Page 40
Operative: Sep 2004 Supersedes: Jul 2004 RANGER 405D Model Index DO NOT attempt to use this Parts List for machine if its code NUMBERS IN THE TABLE BELOW INDICATE WHICH number is not listed. Contact the Service Department for any COLUMN TO USE IN EACH PARTS LIST FOR EACH code numbers not listed.
Page 42
AP-210C Casework Assembly Operative: Jul 2004 Supersedes: Feb 2002 AG1459B A11.03.04M Page 42 Ranger 405D IMA 608D...
Page 43
End Frame Welded Assembly AL2550-5W Lower Front Panel AM3505 Gas Strut (Small) AM3614-1 Control Panel Door (Drop down) AM3542 Control Panel Door (Lift Up) AM3542-1 Control Panel Door (Gas Strut) AM3542-3 Control Panel Door (Gas Strut) AM3542-3W IMA 608D Ranger 405D Page 43...
Page 44
AP-210C.2 Casework Assembly Operative: Jul 2004 Supersedes: Feb 2002 AG1459B A11.03.04M Page 44 Ranger 405D IMA 608D...
Page 45
Right Hand End Frame Panel AL2556 Right Hand End Frame Panel AL2556W Lower Chassis End Panel AM3447 Lower Chassis End Panel AM3447W Radiator End Cover Panel AL2560-2 Radiator End Cover Panel AL2560-4 Radiator End Cover Panel AL2560-4W IMA 608D Ranger 405D Page 45...
AP-210D General Assembly Operative: Jul 2004 Supersedes: Feb 2002 AG1459A A24.3.04M Page 46 Ranger 405D IMA 608D...
Page 47
Choke & Bracket Assy AL2698-1 Note 1 Earlier Codes will need to use the gate harness off the original Rectifier Assembly Note 2 Order AG1381-3 Radiator plus AM3665-1, AM3464 x 2, AS1733-3Z x 10 IMA 608D Ranger 405D Page 47...
Page 48
AP-210D.3 General Assembly Operative: Jul 2004 Supersedes: Feb 2002 AG1459A A24.3.04M Page 48 Ranger 405D IMA 608D...
Page 49
AM3504 Fuel Tank Tray Assy AM3438 Fuel Tank Strap AM3443 Muffler Assy (Vertical outlet) AG1402-3 Heat Shield AM3676 Exhaust Clamp AT3192-2 Exhaust Gasket AT3820-1 Top Radiator Hose (Kubota) K16266-72941 Top Radiator Hose (Perkins) AL2740 IMA 608D Ranger 405D Page 49...
Page 50
AP-210F Front End Frame Module Operative: Jul 2004 Supersedes: Feb 2002 AG1403-7 A27.8.03M Page 50 Ranger 405D IMA 608D...
Page 51
Output Panel Nameplate AM3610 Output Panel Nameplate AG1458 Toggle Switch T10800-39 14 Pin Connector Base S12021-40 Connector Cap S17062-3 Output Terminal Assy M13896-3 End Frame AL2550-3 End Frame AL2550-5 End Frame AL2550-5 End Frame AL2550-5W IMA 608D Ranger 405D Page 51...
Page 56
AP-210H Output Rectifier Assembly Operative: Jul 2004 Supersedes: Feb 2002 Page 56 Ranger 405D IMA 608D...
Page 57
Reed Switch Assy (includes) AS4767 Reed Switch S12334-50 Clamp T8970-17 Copper Lead AM3646 Reed Switch Plate S11797-14 Support Bracket M13430 Note 1 Use AL2463-4. Earlier codes will need to use the Gate Harness of original Rectifier Assy. IMA 608D Ranger 405D Page 57...
AP-210J Auxiliary Output Box Module Operative: Jul 2004 Supersedes: Feb 2002 Australian Model Ref. AL2614-4 European Model Ref. AL2614-1 UK Model Ref. AL2614-2 Page 58 Ranger 405D IMA 608D...
We respond to our customers based on the best information in our One Year* possession at that time. Lincoln Electric is not in a position to warrant or guarantee Ruggerini Engines and Accessories such advice and assumes no liability, with respect to such information or advice. We...