This Beckett DP Series centrifugal pump is magnetically driven and contains no seals to leak or wear
out. It also contains no oil as other types of submersible utility pumps do, thereby eliminating the pos-
sibility of oil leaks which can foul your water. All electrical parts and connections are completely en-
capsulated with epoxy. These features, combined with very low energy consumption, make for a safe
and convenient pump which is economical to operate. In addition, it is essentially maintenance-free.
Use:
The Beckett DP Series pump is designed to operate completely submerged. Cleaning of the filter can
be reduced by placing the pump on a brick or patio stone in the water to raise it above the level of the
debris which accumulates on the bottom.
Prefilter:
Prefilters are supplied with the pump. Using and maintaining clean prefilters will greatly decrease
maintenance in cleaning the impeller assembly as well as providing better water filtration and pump
flow. See Page 2 - Prefilter Cleaning.
Service and
The only serviceable part is the impeller assembly. It can be cleaned and inspected by removing the
screws holding the volute housing in place and lifting out the housing and impeller assembly. See Page
Maintenance:
3 for diagram. Never attempt to disassemble the impeller assembly. If it becomes worn or broken,
simply replace the entire assembly. If the pump is taken out of service for a period of time (such as
during winter), flush the pump out with clean fresh water and drain thoroughly before storing. Ensure
that the cord is protected from wear and abrasion.
NEVER ATTEMPT TO REPLACE OR SHORTEN THE CORD!
SAFETY
1. RISK OF ELECTRIC SHOCK –
ing-type attachment plug (3-prong plug). To reduce the risk of electric shock, be certain that it is
WARNING:
connected only to a properly grounded, grounding-type receptacle. Do not remove the grounding
pin.
2. RISK OF SEVERE ELECTRIC SHOCK –
by a ground-fault circuit-interrupter (GFCI). A GFCI must be provided in accordance with Section
680-51 of the national electric code. Contact a qualified electrician if you cannot verify that the
receptacle is protected by the GFCI.
3. TO REDUCE THE RISK OF ELECTRICAL SHOCK:
A. Never use an extension cord to connect unit to electrical supply; provide a properly located
B. Never bury the 3-prong plug of the cord, it is not waterproof and severe electric shock will
CAUTION:
1. This pump has been evaluated for use with water only.
2. Disconnect pump from power source before handling, servicing or working in the water in which the
pump is operating.
Note:
Your Beckett DP Series pump is cooled and lubricated with water. If the pump is plugged in while it
is out of the water, it is normal for it to rattle. However, while it will continue to operate if allowed to
run dry, it will sustain permanent heat damage after 30 minutes. Your Beckett DP Series pump is in-
tended to pump fresh water only. Do not use to pump oils, solvents, fuels, or salt water. Do not allow
to freeze.
PUMP
MODEL #
VOLTS
DP800
115
DP1200
115
DP1800
115
PUMP MODEL NUMBER AND INFO LOCATED ON PUMP BACKPLATE NEAR POWER CORD
GFCI outlet.
occur.
Hz
AMPS
WATTS
60
.90
70
60
2.2
150
60
2.2
230
This pump is supplied with a grounding conductor and a ground-
Connect only to a grounded receptacle protected
APPROXIMATE PUMP FLOW (GPH @ HEAD)
USING 1" ID HOSE 0N DP800 & DP1200
MAX.
and a 1-1/2" ID HOSE ON DP1800
HEAD
0'
12'-9"
900
14'-8"
1350
16'-4"
1875
B E C K E T T
C O R P O R A T I O N
N o r f o l k • V i r g i n i a
1'
3'
814
652
1232
962
1764
1475
084-121078
5'
512
740
1267

Advertisement

loading

Summary of Contents for Beckett DP800

  • Page 1 Note: Your Beckett DP Series pump is cooled and lubricated with water. If the pump is plugged in while it is out of the water, it is normal for it to rattle. However, while it will continue to operate if allowed to run dry, it will sustain permanent heat damage after 30 minutes.
  • Page 2: Pump Installation

    Operation below. Make sure both Intake Filters (A) are pushed all the way onto the Strainers (B). Next push them onto the T-Filtting (C). Now push the T-Filtting (C) onto the Pump Volute Intake (D) [On the DP800 model Instructions: you must install T- Fitting Adaptor (E) into T-Fitting (C) before installing onto pump volute (D)] making sure the filters are parallel/flat with the Pump base.
  • Page 3 DP1800 DP SERIES SUBMERSIBLE PUMPS HAVING TROUBLE? NEED REPLACEMENT PARTS? CONTACT CUSTOMER SERVICE AT DP1200 1-866-466-4319 DP800 DESCRIPTION DP800 DP1200 DP1800 PART # PART # PART # NEEDED PUMP BODY W/CORD 096-110095 096-050595 096-050596 ROTOR ASSEMBLY (INCLUDES A-E) 096-110094 096-110097...
  • Page 5 The fountain kit is not only ornamentally enjoyable it is also beneficial in aeration, and for movement of the pond water creating a healthier plant and fish environment. Can be used with DP800 & DP1200 pumps only, you must remove the 1”...
  • Page 6 1) Beckett warrants to the original purchaser, the “DP” series pond pump and accessories (Exception - does not include the rotor/impeller assembly or replaceable intake filter material - see Item 2 for warranty on these items) against defects in material and workmanship for 2 years from the date of purchase.

This manual is also suitable for:

Dp1200Dp1800