Monessen Hearth CDV7 Installation And Operating Instructions Manual page 45

Cdvsc7 series, cdv7 series, direct vent gas fireplace
Table of Contents

Advertisement

SIGnaTuRe CoMManD SySTeM opeRaTIon InSTRuCTIonS
FunCTIonS/opeRaTIon
Turning on the fireplace
1. Turn on the master switch and wait for a beep.
. Press the ON button on the Command Center or turn on wall switch. Pilot will light and burner will come on High set-
ting or last memory setting (See Turning Off Fireplace below). For memory feature.
pilot Safety lockout Function
1. If the pilot doesn't light after sparking for 30 seconds, pilot trial lockout happens. The LED on the Command Center
flashes Green once every  seconds, until reset.
. If the pilot flame is lost during normal operation, the system will try three (3) times to relight after three (3) failures,
flame loss lockout happens. The LED on the Command Center flashes Red-Green once every  seconds, until re-
set.
3. Turning the master switch on the Command Center to the off position, then ON again will reset the system.
Flame height Control
1. Press the ON button (on the Command Center) once to turn on the main burner with maximum flame height.
. Press the OFF button to decrease flame height. The first two presses will decrease the flame height to medium and
low.
3. The third press on OFF will turn off the main burner. In standing pilot configuration, the pilot will stay; in intermittent
pilot configuration, the pilot will be shut off.
Turning the Fireplace off
There are three ways to turn the fireplace off.
1. Flip the master switch to the off ("O") position. (This will turn the entire system OFF.)
. Press the OFF button to Medium, Low, then Off.
3. Hold the OFF button anytime for three seconds or by turning off the wall switch. These two commands of OFF are
(Memory Off) the system will remember all last settings before turning off. The next time the fireplace is turned on, all
settings will resume. To reset, change to the desired settings and shut off by using the Memory Off commands and
the system will be reset to those new settings.
Command Center operations:
The following functions are available on the Command Center.
Function
Power Up
Fireplace ON
Fireplace OFF
Flame Height Up
Flame Height Down
Self Diagnostics Chart:
The Command Center has a self-diagnostic LED enabling you to troubleshoot problems and potentially avoid a ser-
vice call. Please refer to the charts below for indicator reference.
Conversion Cover Missing
Spark Fail
No Sensor Signal
Pilot Lockout - trial
Pilot Lockout - flame loss
Low Battery
No or Low Thermopile Power
Learning
AC Power On
Pressure Switch Failed (Power Vent only)
69D3011
Flip the master switch to the ON ("_") position to power up the system
Press the ON ▲ button on the Command Center or turn on wall switch to turn the fireplace on
Flip the master switch to the OFF ("o") position OR press the OFF ▼ button 3
times OR for Memory Off, hold the OFF ▼ button 3 seconds, or turn off wall switch
Press the ON ▲ button once to turn on the fireplace with maximum flame height
Press the OFF ▼ button to lower the flame height to Medium and Low
Fault
CDVSC7 & CDV7 Series Gas Fireplace
operation
leD Indication
One RED (1 time)
Two RED (1 time)
Three RED (1 time)
One GREEN, every  sec. (until manual reset)
One RED-GREEN, every  sec. (until manual reset)
One RED, every 10s (continuously)
Two RED, every 10s (continuously)
GREEN Flashes, every 1 sec. (for 10 sec.)
GREEN solid
One RED every  sec. (until manual reset)
45

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents