Monessen Hearth CDV7 Installation And Operating Instructions Manual
Monessen Hearth CDV7 Installation And Operating Instructions Manual

Monessen Hearth CDV7 Installation And Operating Instructions Manual

Cdvsc7 series, cdv7 series, direct vent gas fireplace
Table of Contents

Advertisement

Installation and Operating
Instructions
waRnInGS
IF The InFoRMaTIon In TheSe InSTRuCTIonS
aRe noT FolloweD exaCTly, a FIRe
oR exploSIon May ReSulT CauSInG
pRopeRTy DaMaGe, peRSonal InjuRy oR
loSS oF lIFe.
Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
whaT To Do IF you SMell GaS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
waRnInG: Improper installation, adjustment,
alteration, services or maintenance can cause
injury or property damage. Refer to this manual.
For assistance or additional information
consult a qualified installer, service agency or
the gas supplier.
This appliance may be installed in an aftermarket*,
permanently located, manufactured home (uSa
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of
gas indicated on the rating plate. This appliance
is not convertible for use with other gases,
unless a certified kit is used.
* aftermarket: Completion of sale, not for purpose of
resale, from the manufacturer.
CDVSC7 Series
CDV7 Series
Direct Vent Gas Fireplace
Models:
CDVR33n/pV7;n/pe7;n/pSC7, CDVT33n/pV7;n/pe7;n/pSC7,
CDVR36n/pV7;n/pe7;n/pSC7, CDVT36n/pV7;n/pe7;n/pSC7,
CDVR42n/pV7;n/pe7;n/pSC7, CDVT42n/pV7;n/pe7;n/pSC7,
CDVR47n/pV7;n/pe7;n/pSC7, CDVT47n/pV7;n/pe7;n/pSC7
Due To hIGh TeMpeRaTuReS, The applIanCe
ShoulD Be loCaTeD ouT oF TRaFFIC anD
away FRoM FuRnITuRe anD DRapeRIeS.
ChIlDRen anD aDulTS ShoulD Be aleRTeD
To The haZaRDS oF hIGh SuRFaCe
TeMpeRaTuRe anD ShoulD STay away To
aVoID BuRnS oR CloThInG IGnITIon.
younG ChIlDRen ShoulD Be SupeRVISeD
when They aRe In The SaMe RooM aS The
applIanCe.
CloThInG oR oTheR FlaMMaBle MaTeRIal
ShoulD noT Be plaCeD on oR neaR The
applIanCe.
Keep The RooM aRea CleaR anD FRee
FRoM CoMBuSTIBle MaTeRIalS, GaSolIne,
anD oTheR FlaMMaBle VapoRS anD
lIquIDS.
InSTalleR: leave this manual with the appliance.
ConSuMeR: Retain this manual for future refer-
ence.
CDVT
CDVR
693011
CDVRT7 cover
69D3011 8/10 Rev. 8

Advertisement

Table of Contents
loading

Summary of Contents for Monessen Hearth CDV7

  • Page 1 * aftermarket: Completion of sale, not for purpose of resale, from the manufacturer. CDVSC7 Series CDV7 Series Direct Vent Gas Fireplace Models: CDVR33n/pV7;n/pe7;n/pSC7, CDVT33n/pV7;n/pe7;n/pSC7, CDVR36n/pV7;n/pe7;n/pSC7, CDVT36n/pV7;n/pe7;n/pSC7, CDVR42n/pV7;n/pe7;n/pSC7, CDVT42n/pV7;n/pe7;n/pSC7,...
  • Page 2: Table Of Contents

    CDVSC7 & CDV7 Series Gas Fireplace pleaSe ReaD The InSTallaTIon & opeRaTInG InSTRuCTIonS BeFoRe uSInG applIanCe. Thank you and congratulations on your purchase of a MhSC fireplace. IMpoRTanT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions fully may result in a possible fire hazard and will void the warranty.
  • Page 3: Important Safety Information

    • immediately call your gas supplier from a neigh- bor’s phone. Follow the gas supplier’s instruc- tions. 69D3011 CDVSC7 & CDV7 Series Gas Fireplace owneR Please retain these instructions for future reference. 4. Never install the fireplace • in a recreational vehicle •...
  • Page 4: Code Approval

    CDVSC7 & CDV7 Series Gas Fireplace 1. Do not use this fireplace to cook food or burn paper or other objects. 13. Never place anything on top of fireplace. 14. Do not use any solid fuels (wood, coal, paper, card- board, etc.) in this fireplace.
  • Page 5: Product Specifications

    Combustible materials may contact the sides, bottom or back of firebox. Do not overlay the black painted face with combustible materials. 69D3011 CDVSC7 & CDV7 Series Gas Fireplace Remote Control Switch Receiver Hi/Lo Knob Off/Pilot/On Knob...
  • Page 6: High Elevations

    CDVSC7 & CDV7 Series Gas Fireplace hIGh eleVaTIonS Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4,500 feet (1,370 m) above sea level. For elevations above 4,500 feet (1,370 m) in USA, installations must be in accordance with the current ANSI Z3.1/NFPA 54 and/or local codes having juris-...
  • Page 7: Fireplace & Framing Dimensions

    15Z\v" (387 mm) 33Z\v" (845 mm) 37Z\x" (953 mm) 35M\," (911 mm) 39" (991 mm) CDVSC7 & CDV7 Series Gas Fireplace Minimum Rough Opening  Depth 5/8” 1/2” 1/2” 5/8” noTe: Model CDVR33SC7 has no standoffs on top of unit. CDVR42(V,e,SC)7 CDVR47(V,e,SC)7 41"...
  • Page 8 CDVSC7 & CDV7 Series Gas Fireplace 5/8” 1/2” Q - Minimum Rough Opening Width 1 ” 15/16” Figure 3 - CDVT Series Fireplace Dimensions CDVT33(V,e,SC)7 33" (38 mm) 35B\," (905 mm) 31ZZ\zn" (805 mm) 7C\zn" (691 mm) 15C\zn" (386 mm) 14C\zn" (360 mm) 1C\," (546 mm) 10ZZ\zn"...
  • Page 9: Pre-Installation Information

    69D3011 CDVSC7 & CDV7 Series Gas Fireplace FIReBox FRaMInG FoR CDVR Firebox framing can be built before or after the appliance is set in place. Construct firebox framing following Figure 2 for your specific installation requirements.
  • Page 10: Fireplace Location

    CDVSC7 & CDV7 Series Gas Fireplace FIReplaCe loCaTIon Plan for the installation of your appliance. This includes determining where the unit is to be installed, the vent configuration to be used, framing and finishing details, and whether any optional accessories (i.e.
  • Page 11: Clearances

    (louvers). This may create a fire hazard. 69D3011 CDVSC7 & CDV7 Series Gas Fireplace Finish Wall Top of Heat Exhaust Vent CDV33/42/47 noTe: CDVR33SC7 has no standoffs.
  • Page 12: Securing Fireplace To Floor Or Framing

    CDVSC7 & CDV7 Series Gas Fireplace The fireplace must be secured to the floor and/or to framing studs as shown in Figure 7. Use two () wood screws or masonry/ concrete screws to secure fireplace to the floor. Use four (4) screws to attach fireplace to framing.
  • Page 13: Venting Installation

    * unless the vertical run is 7Z\x feet or higher (top vent units only), the clearances for the horizontal run is 1" at the top. 69D3011 CDVSC7 & CDV7 Series Gas Fireplace GeneRal VenTInG Your fireplace is approved to be vented either through the side wall, or vertical through the roof.
  • Page 14 CDVSC7 & CDV7 Series Gas Fireplace GeneRal VenTInG InFoRMaTIon - TeRMInaTIon loCaTIon D  E  L  B  Figure 8 - CFM145a  Termination Locations V  A = Clearance above grade, veranda, porch, deck, or balcony B = Clearance to window or door that may be...
  • Page 15: Termination Clearances

    Repeat process with 7” flex vent pipe. The same proce- dure must be performed on the vent side. Figure 10 - Apply high temperature sealant to 4” and 7” pipes. CDVSC7 & CDV7 Series Gas Fireplace Alcove Applications* = Min. 6” (152 mm) for non-vinyl sidewalls Min.
  • Page 16: Rear Vent Installation Only

    CDVSC7 & CDV7 Series Gas Fireplace TwIST loCK pIpeS When using twist lock pipe it is not necessary to use seal- ant on the joints. The only areas of the venting system that need to be sealed with high temperature silicone sealant are the sliding joints of any telescopic vent section used in the system.
  • Page 17: How To Use The Vent Graph

    8’ (.4 m). Refer to Page 24 for snorkel requirements. 69D3011 CDVSC7 & CDV7 Series Gas Fireplace 2  4  6  8 10 12  1 4 16 18  2 0 Horizontal Dimension From the Outside of Termination to the Back of the Fireplace X = "...
  • Page 18: Vent Pipe Clearances

    CDVSC7 & CDV7 Series Gas Fireplace VenT pIpe CleaRanCeS A Minimum of 3" Clearance to the Top Is Required Along Horizontal Length until Flue Pipe Penetrates Outside Wall. CDVR Series FP89 Figure 14 - Combustible Clearances for Vent Pipe FP2289 RV rear vent...
  • Page 19: Rear Vent Applications & Installation

    Figure 16 noncombustible walls: Hole opening should be 7Z\x” (191 mm) diameter. 69D3011 CDVSC7 & CDV7 Series Gas Fireplace Vent opening for Combustible walls 9B\,” (44 mm) Min. Fireplace Hearth...
  • Page 20 CDVSC7 & CDV7 Series Gas Fireplace Finish Wall Figure 17 - Side View of Final Unit Location FP2294 ReaR wall VenT InSTallaTIonS - Side View Vent Termination 1/25/00 djt Flex VenT pIpe Follow Steps 1 and  on Page 19.
  • Page 21 V584-01 Max 20" 1 + 2 + 3 + 4 = 270° FP1180 Figure 25 - Maximum Elbow Usage CDVSC7 & CDV7 Series Gas Fireplace A + B = 17’ (Max.) (5.2m) 7’6" (2.3m) Figure 23 - Horizontal Run Reduction 10’...
  • Page 22: Vertical Sidewall Installation

    CDVSC7 & CDV7 Series Gas Fireplace VeRTICal SIDewall InSTallaTIon - TwIST loCK pIpe Step 1 Locate vent opening on the wall. It may be necessary to first position the fireplace and measure to obtain hole lo- cation. Depending on whether the wall is combustible or noncombustible, cut opening to size.
  • Page 23 Step 5 Slide the 7” (178 mm) flex vent pipe over the 4” flex vent pipe and secure the 7” collar as described on Page 14. 69D3011 CDVSC7 & CDV7 Series Gas Fireplace 4” Flex Vent Pipe Spacer Spring FP1474...
  • Page 24: Below Grade Installation

    CDVSC7 & CDV7 Series Gas Fireplace Below GRaDe InSTallaTIon When it is not possible to meet the required vent terminal clearances of 1” (305 mm) above grade level, a snor- kel kit is recommended. It allows installation depth down to 7” (178 mm) below grade level. The 7” (178 mm) is measured from the center of the horizontal vent pipe as it penetrates through the wall.
  • Page 25: Vertical Through-The-Roof

    7. Install roof support (Figure 37) and roof flashing mak- FP1179 ing sure upper flange is below the shingles. Figure 39 8. Install appropriate pipe sections until the venting is above the flashing. Figure 39 CDVSC7 & CDV7 Series Gas Fireplace Figure 35 - Vertical Through-the-Roof Restrictor FP2304...
  • Page 26 CDVSC7 & CDV7 Series Gas Fireplace 9. Install storm collar and seal around the pipe. 10. Add additional vent lengths for proper height. Fig- ure 39 11. Apply high temperature sealant to 4” and 7” collars of vertical vent termination and install.
  • Page 27: Fireplace Installation

    Down When using copper of flex connectors use only fittings approved for gas connections. The gas control inlet is 3/8" NPT. FP1977 CDVSC7 & CDV7 Series Gas Fireplace • Sealant (resistant to propane/LP gas) • Test gauge connection* •...
  • Page 28 CDVSC7 & CDV7 Series Gas Fireplace only persons licensed to work with gas piping may make the necessary gas connections to this appliance. noTe: The gas line connection may be made using 1/" rigid tubing or an approved flex connector.
  • Page 29: Check Gas Pressure - Millivolt

    Code anSI/nFpa 70 (latest edition) and Canadian electrical Code, CSa C22.1. 69D3011 CDVSC7 & CDV7 Series Gas Fireplace Pressure Test “IN” Pressure Test “OUT” HI/LO Knob...
  • Page 30: Electrical Installation

    CDVSC7 & CDV7 Series Gas Fireplace ReMoTe wall MounTeD SwITCh A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach the wall switch in a junction box at the desired location on the wall. Figure 43. Do not extend beyond the wall switch wire length provided.
  • Page 31: Electronic Pilot Ignition Wiring

    10 VAC to be wired to the factory installed junction box before the fireplace is permanently installed. Figure 46 Speed Control Black Figure 46 - Blower Wiring Diagram 69D3011 CDVSC7 & CDV7 Series Gas Fireplace Electronic Valve WHITE #3 GRAY #7 FP2295 electronic wiring diagram Receptacle Junction Box...
  • Page 32: Operating Instructions - Millivolt

    CDVSC7 & CDV7 Series Gas Fireplace FoR youR SaFeTy ReaD BeFoRe lIGhTInG a. This appliance is equipped with a pilot which must be lit with built-in piezo ignitor while following these instructions exactly. B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
  • Page 33: Lighting Pilot

    Release and check that pilot continues to burn. If the pilot does not stay lit, repeat steps 1 and . 69D3011 CDVSC7 & CDV7 Series Gas Fireplace NOTE: Remove any excessive pipe compound from the connections. Excessive pipe compound can set off electronic sniffers.
  • Page 34: Lighting Burner

    CDVSC7 & CDV7 Series Gas Fireplace MaIn BuRneR SwITCh The “ON/OFF/RS” switch for the main burner can be found behind door of the fireplace. This switch allows you to turn on and to turn off the main burner without using the gas valve knob. Make sure the button is in the “ON”...
  • Page 35: Operating Instructions Electronic Ignition

    3. Turn off all electric power to the appliance if service is to be performed. 4. Close lower door. 69D3011 CDVSC7 & CDV7 Series Gas Fireplace If you do not follow these instruction exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 36: Check Gas Pressure - Signature Command System 36 Electrical Installation - Scs

    CDVSC7 & CDV7 Series Gas Fireplace SIGnaTuRe CoMManD - CheCK GaS pReSSuRe and eleCTRICal InSTallaTIon 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, STop! Do not install the appliance.
  • Page 37: Junction Box Wiring

    Snap on wall cover provided and screw to junction box. 69D3011 CDVSC7 & CDV7 Series Gas Fireplace Junction Box Figure 54 - Junction Box Wiring Diagram FP1912...
  • Page 38: Signature Command System Wiring Diagram

    CDVSC7 & CDV7 Series Gas Fireplace To Junction Box in Fireplace Optional White Light Black Optional White Blower Black White Optional Black Aux. Green Input 300 Watt Max. Each Optional A/C Module Replaces 6V Adapter When Used 6V AC Adapter noTe: Wall switch wires must be con- nected together if a wall switch is not being used.
  • Page 39: Optional Fan/Blower System - Scs

    Optional WHITE Light BLACK WHITE BLACK Optional WHITE GREEN FP2103 AC fan wiring CDVSC7 & CDV7 Series Gas Fireplace optional aC Module Connector Pin To Contro  l  Box Control Box FP103...
  • Page 40: Blot Automatic Thermostat Blower

    CDVSC7 & CDV7 Series Gas Fireplace BloT auToMaTIC TheRMoSTaT BloweR WHITE Before installing the blower, wire the receptacle into an electrical circuit. This should be done before framing the fireplace. Wire with minimum 60° C wire in accordance with prevailing codes.
  • Page 41: Operating Instructions - Scs

    69D3011 If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of lie. CDVSC7 & CDV7 Series Gas Fireplace continued on next page...
  • Page 42: Operating Instructions

    CDVSC7 & CDV7 Series Gas Fireplace opeRaTInG InSTRuCTIonS 1. STop! Read the safety information above. . This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. 3. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STop! Follow "B"...
  • Page 43: Signature Command System

    4. When the four (4) batteries are installed the system will operate without power. 5. The batteries should be replaced when the LED indicates low battery or at least once a year. 69D3011 CDVSC7 & CDV7 Series Gas Fireplace RF Receiver ON/OFF...
  • Page 44: System Configuration/Setup

    CDVSC7 & CDV7 Series Gas Fireplace SySTeM ConFIGuRaTIon/SeTup All System configuration/setup is done on the Command Center. noTe: When using On/Off wall switch, the switch must be in the ON position to perform all configuration set ups at the command center.
  • Page 45 Low Battery No or Low Thermopile Power Learning AC Power On Pressure Switch Failed (Power Vent only) 69D3011 CDVSC7 & CDV7 Series Gas Fireplace operation leD Indication One RED (1 time) Two RED (1 time) Three RED (1 time) One GREEN, every  sec. (until manual reset) One RED-GREEN, every  sec.
  • Page 46: Glass Removal

    CDVSC7 & CDV7 Series Gas Fireplace GlaSS FRaMe ReMoVal 1. Remove upper and lower louvers. . Release the clamps on the bottom of the fireplace. Figure 61 3. Tilt glass frame out and lift glass frame up until it clears the hook on top of the frame.
  • Page 47: Log Placement

    Do not sprinkle the lava rock or ember chunks on top of the burner. This may cause potential sooting, glass breakage and a fire hazard 69D3011 CDVSC7 & CDV7 Series Gas Fireplace Top Right Log, Top Left Log, #3 Rear Log, #1 Center Vertical Grate Bar...
  • Page 48: Cleaning And Maintenance

    CDVSC7 & CDV7 Series Gas Fireplace Turn off gas before servicing fireplace. It is recommended that a qualified service technician perform these check-ups at the beginning of each heating season. BuRneR, pIloT anD ConTRol CoMpaRT- MenT Keep the control compartment, logs, and burner areas surrounding the logs clean by vacuuming or brushing at least twice a year.
  • Page 49: Vent System

    To place logs back in the fireplace, Refer to “Log Placement” section in this manual. NOTE: Do not use fluids to clean ceramic fiber logs. RoCK wool Replace or add rock wool as required following installation instructions in the Final Installation section of this manual. 69D3011 CDVSC7 & CDV7 Series Gas Fireplace...
  • Page 50: Troubleshooting

    CDVSC7 & CDV7 Series Gas Fireplace STanDInG pIloT IGnITIon SyMpToM poSSIBle CauSe 1. Spark ignitor will A. Wire disconnected. not light pilot after repeated triggering of B. Defective ignitor. piezo. C. No gas or low gas pres- sure. D. No Propane/LPG in tank .
  • Page 51: Troubleshooting

    A. Insufficient fresh air being and lifts off burner supplied (ghosting) 69D3011 CDVSC7 & CDV7 Series Gas Fireplace aCTIon A. Clean and adjust the pilot flame for maximum flame impingement on thermocouple. A. Check for flue product leak. Replace defective pipe sec- tion.
  • Page 52: Electronic Ignition

    CDVSC7 & CDV7 Series Gas Fireplace eleCTRonIC IGnITIon STaRT 1. Turn gas supply off. . Turn ON/OFF switch to “ON” Power to module (4V Normal) Is there a spark across ignitor sensor gap? Turn on gas. Does pilot burner light?
  • Page 53: Signature Command System

    The Control Board is having interference from the surrounding metal (Ground) Check gas supply Go through FP1911 troubleshoot sc 8/08 CDVSC7 & CDV7 Series Gas Fireplace DIAGNOSIS Battery polarity wrong? Re-install batteries Battery voltage low? Change batteries AC plug is plugged to...
  • Page 54: Replacement Parts

    CDVSC7 & CDV7 Series Gas Fireplace ReplaCeMenT paRTS FIReBox CoMponenTS (CDVT Series) (CDVR Series) 7,10,11,13 69D3011...
  • Page 55 L30BR L3BR L30PW L30PW L3PW BLOT BLOT BLOT FK1 FK1 FK1 6D0746 6D0746 6D0746 BLOTSC BLOTSC BLOTSC CDVSC7 & CDV7 Series Gas Fireplace CDVT36 CDVR42 CDVT42 CDVR47 6D0695 6D0697 6D0697 6D0699 69D008 69D1107 69D1107 69D105 6D870 6D870 6D870 6D870 69D0041...
  • Page 56: Standing Pilot - Millivolt Control

    CDVSC7 & CDV7 Series Gas Fireplace STanDInG pIloT — MIllIVolT ConTRol 693011 CDV millivolt parts ReplaCeMenT paRTS 11,12,13,14 69D3011...
  • Page 57 RCST, RCT, RCSTE, RCSTEB, RCSITE, WWTD RCB, RCMT, RCBE, WMTD Kit #CDV33CKP Kit #CDV36CKP Kit #CDV4CKP Kit #CDV47CKP Kit #CDV33CKN Kit #CDV36CKN Kit #CDV4CKN Kit #CDV47CKN CDVSC7 & CDV7 Series Gas Fireplace 37D0117 37D0118 37D0117 37D0018 37D0019 37D0018 37D1067 37D1067 37D1067...
  • Page 58: Electronic Ignition

    CDVSC7 & CDV7 Series Gas Fireplace eleCTRonIC IGnITIon Item Description qty. CDV33ne7 CDV33pe7 CDV36ne7 CDV36pe7 CDV42ne7 CDV42pe7 CDV47ne1 CDV47pe7 Gas Valve Assy. 37D0016 Pilot Assembly 37D000 Burner Tube 54D088 Flexhose with Shut-off Valve 69D0030 Rocker Switch 41D0048 Injector 58D0371 Burner Assembly...
  • Page 59: Signature Command System

    ReplaCeMenT paRTS SIGnaTuRe CoMManD SySTeM 69D3011 13,14,15,16,17 693011 cdvrt7 SC parts CDVSC7 & CDV7 Series Gas Fireplace...
  • Page 60 CDVSC7 & CDV7 Series Gas Fireplace SIGnaTuRe CoMManD SySTeM Item Description qty. CDVR33 nSC7 1. Gas Valve Assy. 80D0001 . Pilot Assembly 80D0006 3. Control Box 80D0018 4. Command Center 80D0005 5. Burner Tube 0301096 0301096 54D609 54D609 6. Flexhose with...
  • Page 61: Logs

    Item Description CDVR33SC7 Rear Log 03010 Right Log 54D0147 Left Log 54D0146 69D3011 CDVR33(V,e)7 CDV(R,T)36(V,e,SC)7 693011 54D011 54D0181 54D0147 54D0116 cdv log parts 54D0146 54D0115 CDVSC7 & CDV7 Series Gas Fireplace CDV(R,T)42(V,e,SC)7 CDV(R,T)47(V,e,SC)7 54D0339 54D0361 54D0360 54D0339 54D0361 54D0360...
  • Page 62: Venting Components

    CDVSC7 & CDV7 Series Gas Fireplace VeRTICal VenTInG Vertical Vent Termination Kits Twist Lock Pipe 584B Vent components Starter Kit 2/25/99 djt Twist Lock Elbows Shields and Supports 584D Vent Components 584C 90 degree elbow Vent components 2/25/99 djt 45 degree elbow...
  • Page 63: Horizontal Venting

    45° Elbow for Vertical Offsets - 8 pack 90° Elbow for Vertical/Horizontal Offset 90° Elbow for Vertical/Horizontal Offset - 8 pack 1" Firestop 3" Firestop 1" Attic Insulation Shield Combination Horizontal Offset/Roof Support CDVSC7 & CDV7 Series Gas Fireplace Model number 7TBRHTK 7TDVSCTK 7TRVCT/8 7TRVHT/8 7TRVTG...
  • Page 64 CDVSC7 & CDV7 Series Gas Fireplace 69D3011...
  • Page 65 CDVSC7 & CDV7 Series Gas Fireplace 69D3011...
  • Page 66: Massachusetts Requirements

    CDVSC7 & CDV7 Series Gas Fireplace Massachusetts Residents only — please read and follow these special requirements noTe ReGaRDInG VenTeD pRoDuCTS This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts.
  • Page 67: Warranty

    CDVSC7 & CDV7 Series Gas Fireplace lIFeTIMe waRRanTy The following components are warranted for life to the original owner, subject to proof of purchase: Firebox, Combustion Chamber, Heat Exchanger, Grate and Stainless Steel Burners. FIVe yeaR waRRanTy The following components are warranted five (5) years to the original owner, subject of proof of purchase: Ceramic Fiber Logs.
  • Page 68: Energuide Efficiencies

    efficiency Ratings Model enerGuide Ratings Fireplace efficiency (%) CDVR33NV7 6.6 CDVR33PV7 64.3 CDVR33NE7 66.8 CDVR33PE7 68.1 CDVR33NSC7 57.6 CDVR33PSC7 64.3 CDVR36NV7 47.7 CDVR36PV7 53.6 CDVR36NE7 49.7 CDVR36PE7 56.1 CDVR36NSC7 49.7 CDVR36PSC7 56.1 CDVR4NV7 66.8 CDVR4PV7 68.7 CDVR4NE7 71.0 CDVR4PE7 7.3 CDVR4NSC7 71.0 CDVR4PSC7...

Table of Contents