Download Print this page

Moen 8410 Installation Instructions

Lavatory faucets four-inch centerset

Advertisement

Quick Links

8410, 8415, 8416, 8450, 8455
LEVER HANDLE
1-3/4"
3-5/8" C.C.
CONCENTRIX HANDLE
1-3/4"
3-5/8" C.C.
CAUTION:
Before turning water on during either rough-in or trim-out, make sure that the cartridge retainer clip is in place. The cartridge
and retainer clip were properly installed and tested before leaving the factory. Although it is unlikely, it is nevertheless possible
that through the handling of the valve by any number of persons the retainer clip may not be properly installed. This should
be carefully checked at time of rough-in and trim-out. If the retainer clip is not properly installed, water pressure could force
the cartridge out of the casting. Personal injury or water damage to the premises could result.
®
LAVATORY FAUCETS
Four-Inch Centerset
5" NOMINAL
OPEN
POSITION
1-3/4"
MAX.
1/2" IPS
THREADED
CONNECTIONS
CONCENTRIX
HANDLE INSERT
5" NOMINAL
OPEN
POSITION
Fits 4" centers and through a 1" minimum diameter hole.
All models equipped with a Moen Flow-Rator™.
Complies with ASME A112.18.1M and CSA B125
Always turn water off before disassembling the valve. Open valve handle to alleviate
water pressure to insure that complete water shut-off has been accomplished.

INSTALLATION INSTRUCTIONS

KNOB HANDLE
1-3/4"
6" X 2" WIDE
USE SPACER TO INSTALL
ON THINNER LAVATORY
BOWLS OR COUNTERS
4-3/4"
DISCARD SPACER WHEN
INSTALLING ON THICKER
LAVATORY BOWLS OR COUNTERS
LIFT ROD
POSITION
With clamp bar, spacer and
mounting nut installed, tilt
clamp bar back as shown,
then drop faucet supplies
down through deck holes and
tighten from below. On decks
thicker than 3/4" you may
have to remove spacer.
MT138A
5" NOMINAL
OPEN
POSITION
3-5/8" C.C.
TILT BACK
CLAMP BAR
CLIP
EAR

Advertisement

loading

Summary of Contents for Moen 8410

  • Page 1: Installation Instructions

    On decks POSITION thicker than 3/4" you may have to remove spacer. Fits 4" centers and through a 1" minimum diameter hole. All models equipped with a Moen Flow-Rator™. Complies with ASME A112.18.1M and CSA B125 MT138A INSTALLATION INSTRUCTIONS KNOB HANDLE 5"...
  • Page 2 Installation Be sure lavatory or mounting surface is clean and dry. Place a bead of plumber's putty around the inside lip of the gasket, position gasket on deck. Assemble clamp bars, spacers if needed, and mounting nuts to escutcheon sutds. Tilt clamp bars back as shown in illustration, then place faucet supplies and sutds down through the deck holes.
  • Page 3 For All Models: 2. Using the cartridge twisting tool (furnished with the new Moen cartridge) and pliers, turn the cartridge back and forth between 11 and 1 o'clock, then grasp the cartridge stem and pull out the cartridge. If the cartridge is difficult to remove, use a Moen cartridge puller.
  • Page 4: Consumer Information

    • If you are concerned about lead in your water, have your water tested by a certified laboratory in your area. Moen Incorporated 25300 Al Moen Drive, North Olmsted, OH 44070-8022, U.S.A. MT138A SEP 95...

This manual is also suitable for:

8415841684508455Mt138a