Download Print this page

Moen 2200 Series Installation Instructions

Tub and shower valves

Advertisement

Quick Links

MODELS 2200, 2400 & 72200 SERIES
TUB AND SHOWER VALVES
All models have 4 port castings. Stops are optional on all models. All models are also available for 1/2 inch I.P.S. pipes
or 1/2 inch copper sweat connections to copper water tubing. The 2400 series include built in pushbutton diverter.
Measurements
These are shown in the drawings. The depth
measurement is critical. Use the front face of
the plaster ground as a reference point for the
finished wall position, including tile (2-1/16"
[51mm]).
The center line of the supply and
discharge piping should be a maximum of 2-3/16"
(56mm) and a minimum of 1-7/16" (37mm) behind
the finished wall surface.
HANDLE
UP
UP
CAUTION:
Before turning water on during either rough-in or trim-out, make sure that cartridge retainer clip is in place. The
cartridge and retainer clip were properly installed and tested before leaving the factory. Although it is unlikely, it is
nevertheless possible that through the handling of the valve by any number of persons the retainer clip may not be
properly installed. This should be carefully checked at time of rough-in and trim-out. If the retainer clip is not properly
installed, water pressure could force the cartridge out of the casting. Personal injury or water damage to the
premises could result.
®
HANDLE
KNOB
O-RING
ESCUTCHEON
COVER
HANDLE
WASHER
SCREW
2400 MODEL SERIES
PUSH BUTTON DIVERTER
MODEL ILLUSTRATED
Always turn water off before disassembling the valve. Open valve handle to
alleviate water pressure to insure that complete water shut-off has been
accomplished.

INSTALLATION INSTRUCTIONS

THESE INSTRUCTIONS MUST BE
WALL LINE
2-1/16"
(52mm)
PLASTER
GROUND
UP
FLOOR
LEFT WITH HOMEOWNER
ALL DIMENSIONS NOMINAL
IMPORTANT: SEE FLUSHING
INSTRUCTIONS PAGE 2
1-1/4"
(32mm)
SUPPLY 1/2" I.P.S. OR
COPPER SWEAT
COMBINATION
MODELS 32"
(813mm)
CAUTION:
USE 1/2" IRON
PIPE SIZE
MINIMUM. DO
NOT USE 1/2"
TUBING, EXCEPT
WHEN SLIP FIT
SPOUT IS USED.
CLIP
EAR
MT659C
6'6"
(1981mm)
SHOWER
45"
(1143mm)
48"
(1219mm)

Advertisement

loading

Summary of Contents for Moen 2200 Series

  • Page 1: Installation Instructions

    MODELS 2200, 2400 & 72200 SERIES TUB AND SHOWER VALVES All models have 4 port castings. Stops are optional on all models. All models are also available for 1/2 inch I.P.S. pipes or 1/2 inch copper sweat connections to copper water tubing. The 2400 series include built in pushbutton diverter. Measurements These are shown in the drawings.
  • Page 2 1/2 inch copper water tube. Connect the bottom outlet to the tub spout using 1/2 inch iron pipe size. 1/2 inch copper water tube can be used with the Moen Slip Fit Spout. WARNING: Secure all pipes and the shower and tub drop ells. Use Teflon tape on all threads.
  • Page 3 Turn OFF both hot and cold water supplies, then open faucet to relieve pressure. Remove handle cover from handle knob. Take out handle screw and remove handle knob, washer, and stop tube. Lift out retainer clip. Rotate cartridge shell back and forth with Moen cartridge twist wrench, grasp the cartridge stem with pliers, and pull out the cartridge.
  • Page 4 HELPLINE: Call our toll free Helpline number, (800) BUY - MOEN (289-6636) for answers to any product, installation, replacement parts, or warranty questions. 25300 Al Moen Dr., North Olmsted, OH 44070-8022 U.S.A. ® © Moen Incorporated 1996 Printed in U.S.A...

This manual is also suitable for:

2400 series72200 series